Note: Retain the shipping crate, brackets and hardware incase the ProJet™ Production Printing System needs to be shipped back to
the manufacturer for repair. These crates are designed to allow fast, easy removal and packaging of the product. If printer needs to be
return to the manufacturer, contact 3D Systems Customer Support for shipping instructions.

09.0 Limitation of Liability

3D Systems is not, in any event, liable for any damages, including lost profits, cost of cover, or other special, incidental, consequential, or indirect
damages arising from the use of this document, however caused and on any theory of liability. This limitation will apply even if 3D Systems or an
authorized dealer or representative has been otherwise advised of the possibility of such damage. This document, in whole or in part, may be
changed or modified at any time at the sole discretion of 3D Systems, without notice.

10.0 Thank You

3D Systems is confident that you will be very satisfied with the purchase of your ProJet™ Production Printing System. Enjoy the ability to produce
high quality parts from your 3-D digital data. We are dedicated to developing a relationship that extends beyond the terms of the sale. Please take
the time to contact 3D Systems with questions, comments or suggestions about your ProJet™ Production Printing System, or other products or
services. 3D Systems strives for higher quality, better products, and comprehensive services to benefit our customers.

11.0 Contacting 3D Systems

For information or assistance, contact 3D Systems' corporate headquarters at:

3D Systems Corporation
333 Three D Systems Circle
Rock Hill, SC 29730
Toll-Free Number: (800) 889-2964
Phone Number: (803) 326-4080
Web: www.3dsystems.com
Email: more info@3d systems.com

For Customer Support:

Region

Telephone

Email

North America

(800) 793-3669

3DWW-MJM Customer [email protected]

Europe

+49 (0) 6151 357357

 

For localized service or support, contact the appropriate 3D Systems regional facilities listed
below:

Region

Telepone

Fax Number

Email

France

+33 1 69351717

+33 1 69351718

hotline.fr@3d systems.com

Germany

+49 6151 357 357

+49 6151 357355

hotline.de@3d systems.com

Hong Kong

+852 2923 5077

+852 2574 4200

asian info@3d systems.com

Italy

+39 039 68 904 00

+39 039 68 81156

Marketing.IT@3d systems.com

Japan

+03 5451 1690

+03 5451 6630

japan info@3d systems.com

Portugal

+33 1 69 35 17 17

 

 

Spain

+33 1 69 35 17 17

 

 

UK

+44 1442 282600

+44 1442 282661

[email protected]

Contact the following Account Representative:

Name: _________________________________________________
Address: _______________________________________________
_______________________________________________________
_______________________________________________________
Tel: ____________________________________________________
Fax: ___________________________________________________

Содержание ProJet 5000

Страница 1: ... 5 3 05 3 Unit Portability 6 1 5 4 05 4 Electrical 7 1 5 5 05 5 Client Workstation Requirements 7 1 5 6 05 6 Network Interface 8 1 5 7 05 7 Material Storage 8 1 5 8 05 8 Material Bottle Disposal 9 1 5 9 05 9 Weights and Measures 9 1 6 06 0 Operating Enviroment 9 1 6 1 06 1 Air Conditioning 9 1 6 2 06 2 Humidity 10 1 6 3 06 3 Lighting 10 1 6 4 06 4 Vibration and Shock 10 1 7 07 0 Preparation for Sh...

Страница 2: ...ng 06 4 Vibration and Shock 07 0 Preparation for Shipment Arrival 08 0 MDM Bottle Build Platform Installations 09 0 Limitation of Liability 10 0 Thank You 11 0 Contacting 3D Systems 12 0 Printer Advance Preparation Checklist 01 0 About this Manual This document includes all of the overall facility requirements that will be needed to have a successful installation when our 3D Systems Customer Suppo...

Страница 3: ...th bypass engaged is accessible in the vicinity of this sign or behind the access panel Avoid contact Hot surfaces can cause severe A hot surface burns Access panels are for service only and should be opened only by certified service personnel or trained maintenance personnel Indicates that skin or eye irritation could result while exposed to a chemical composition Harmful Irritant Warning When ac...

Страница 4: ...ow is a suggested floor plan for a ProJet Production Printing System installation Each printer requires use of a dedicated circuit Multiple printers CAN NOT be located on a single circuit An additional 110 or 220 VAC outlet is recommended for service needs A phone near the printer is recommended to facilitate machine support Each location of the machine requires a standard wall power outlet or pow...

Страница 5: ......

Страница 6: ... for use on rough or uneven surfaces including deep carpet To avoid the risk of tipping the printer when moving between locations only push from the side of the printer The printer is intended to be lifted from its crate base using a fork lift device and place on casters to roll to its final destination Leveled fork lift pads have been placed beneath the machine to accommodate this need The front ...

Страница 7: ...specially in areas where circuits may be affected by an outside source i e lightning required strikes power interruption etc They should have a Some examples of suppliers are Toshiba or APC Power loss during a build will fail the build and minimum rating of 3KVA can cause damage to your printer Uninterruptible power is critical to the successful operation of the machinery 05 5 Client Workstation R...

Страница 8: ...k Not all networks have the TCP IP installed Make sure to have a network administrator check that TCP IP are both installed and are running as required PRIOR TO THE ARRIVAL of the printer 05 7 Material Storage VisiJet part and support materials should uie stored in a conveniently located storage cabinet in proximity to the printer itself A cabinet is recommended to protect against long term exposu...

Страница 9: ...acing the printer in any environment with airborne contaminant including cigarette smoke fumes and mechanical particulates that can adversely affect the long term functioning of this equipment Each ProJet Production Printing System undergoes an operational test at the factory and is shipped with a limited residual amount of build and support material already in its internal reservoir When ordering...

Страница 10: ... qualified 3D Systems Field Service Engineer or an authorized reseller The following topics should be arranged PRIOR TO THE ARRIVAL OF THE SYSTEM to simplify installation of the ProJet Production Printing System Refer to later sections of this guide for details of this procedure Make sure the following resources are available ____ A forklift or similar heavy duty equipment required for unloading t...

Страница 11: ...t Before removing bottle from the MDM re tighten bottle cap to prevent spillage To remove bottle open material delivery module and press release latch down and lift bottle out of module Build Platform Ensure that the corner guides on the backside of platform are clean and free of debris If debris exists when installing the platform guides will not lock into the platform elevator NOTE Clean platfor...

Страница 12: ...ing System or other products or services 3D Systems strives for higher quality better products and comprehensive services to benefit our customers 11 0 Contacting 3D Systems For information or assistance contact 3D Systems corporate headquarters at 3D Systems Corporation 333 Three D Systems Circle Rock Hill SC 29730 Toll Free Number 800 889 2964 Phone Number 803 326 4080 Web www 3dsystems com Emai...

Страница 13: ...________________ Email _____________________________________________________________________ Please place a check in each box once that item is complete Check Box Final installation site selected The intended physical location for each ProJet Production Printing System s should be selected in advance and checked for adherence to the guidelines set out in this guide If required by the shipper a met...

Страница 14: ...nter is installed we agree not to alter any requirements without consulting with 3D Systems Customer Service Representative If alteration are made without consulting 3D Systems it may void the system s warranty ___________________________________ _______________ Customer Signature Date Please return a copy of the check list by FAXING it to the appropriate fax number provided in Contacts ...

Отзывы: