3D Systems, Inc.
54
Output Report
•
After a successful run of the modelerbatch, the application will output a report (ReportFile or IniFile) to the location designated
in the command script . See example below .
•
If building in UHD Mode, “Number of Parts” includes the Verification Strip in the part total.
•
After a machine is put “Online”, there is a period of time that a job takes to initialize . During that time, the Status returned will
be “Not Printing” and the End Time, Total Build Time and Remaining Build Time will all report “Not Estimated” . Once the state
changes to “Printing”, these values will be reported accurately .
Exit Error Codes
•
The Printer Batch Processing applications including ModelerBatch .exe and ModelerStatus .exe will return exit error codes if
there are any issues while the application is running . The following table gives a description of each possible error code that
may be reported while running either application .
Exit Error
Code
Error Description
Description
0
No Error
500
The iniFile is not specified for batch processing
Specify the parameter IniFile as the argument
501
The specified iniFile does not exist or cannot be
opened
Please make sure the IniFile exist
502
IP Address field not present
Add the IP address
503
IP address cannot be validated
Check the IP address
504
Number of Parts field does not present
The number of parts must be specified and larger than 0
505
STL file for Part# can not be found
Missing the STL file. Make sure it exists and accessible
506
Communication error . Unknown printer type or
printer not connected .
Please check IP address . .
507
Verification Strip file cannot be found.
Reinstall the client or restore the verification strip files.
508
Wait time-out .
Please verify the network and increase the wait timeout in
the IniFile .
509
Cannot connect to the printer .
Please check IP address .
510
Part outside platform or exceed platform size
Check the size and position of all parts to ensure that they
will fit inside the platform
511
Too much part data for Auto Part Placement or
Quick Build Placement
Please not use Auto Part Placement or Quick Build .
For example, use Print Preview and manually position the
geometries .