Configuring Basic SIP Parameters
After accessing the Embedded Web Server (see
Accessing the Embedded Web Server
) the
SIP ‘Quick Setup’ screen is displayed, shown in
Figure 8
V6100/SIP Quick Setup
To configure basic SIP parameters, follow these 10 steps:
1
If the V6100 is connected to a router with NAT enabled, perform the following procedure.
If it isn’t, leave the ‘NAT IP Address’ field undefined.
Determine the “public” IP address assigned to the router (by using, for instance,
router Web management). Enter this public IP address in the ‘NAT IP Address’ field.
Enable the DMZ configuration on the residential router for the LAN port where the
V6100 gateway is connected. This enables unknown packets to be routed to the
DMZ port.
2
Under ‘SIP Parameters’, enter the V6100 domain name in the field ‘Gateway Name’. If
the field is not specified, the V6100 IP address is used instead (default).
3
When working with a Proxy server, set ‘Working with Proxy’ field to ‘Yes’ and enter the IP
address of the primary Proxy server in the field ‘Proxy IP address’. When no Proxy is
used, the internal routing table is used to route the calls.