Installing a NetWare Server Driver
49
NAME=<name>
An optional name for identifying this
logical board. NAME is commonly used when you bind
a protocol to the driver. This parameter is limited to 17
alphanumeric characters and must be unique among all
logical boards in the file server.
Finding the Slot Number Manually
This section shows
how to manually determine the slot numbers of two
3C359B NICs installed in a file server. You do not need to
take these actions if you want to enter the slot numbers
when prompted by the server.
The samples below show the server console display when
two 3C359B NICs are installed.
This is the LOAD/BIND sequence for the first of two NICs:
FS1:load c:tlnkpodi
Loading module tlnkpodi.lan
3Com TokenLink PCI Server MLID
Version 1.00c [date]
(C) Copyright 1993-97, 3Com Corp. All
rights reserved
Supported slot values are 1,2
Slot: 1
Data Rate = 16 Mbps.
Max Packet Size = 17954
IO Address Base = F480
Memory Basic Address = FF9EFE800
IRQ = 10
Number of transmit buffers (DPDs) configured = 5.
Number of receive buffers (UPDs) configured = 3.
MicroCode Version String = 01.20 10/20/97
The supported slot values shown are for the two 3C359B
NICs in the server. The next line is where you enter the
address that you will use.
This is the LOAD/BIND sequence for the second of two
NICs:
FS1:load c:tlnkpodi
Do you want to add another frame type for a
previously loaded board? n
Supported slot values are 4
Slot: 4
Data Rate = 16 Mbps.