background image

 

®

 

http://www.3com.com/

 

SuperStack

 

®

 

 II Switch 3900

Getting Started Guide

 

Part No. 10005622
Published April 1998

Содержание iRadar S120R

Страница 1: ... http www 3com com SuperStack II Switch 3900 Getting Started Guide Part No 10005622 Published April 1998 ...

Страница 2: ...ed with limited rights only as provided in DFAR 252 227 7015 Nov 1995 or FAR 52 227 14 June 1987 whichever is applicable You agree not to remove or deface any portion of any legend provided on any licensed program or documentation contained in or delivered to you in conjunction with this User Guide EMISSIONS COMPLIANCE STATEMENTS FOR CLASS A PRODUCTS United States Federal Communications Commission...

Страница 3: ...ect connection to the public telecommunication network AUSTRALIAN EMC FRAMEWORKS COMPLIANCE This product conforms to the EMC Frameworks and meets the Class A limits of AS3548 TRADEMARKS Unless otherwise indicated 3Com registered trademarks are registered in the United States and may or may not be registered in other countries 3Com the 3Com logo SuperStack and Transcend are registered trademarks of...

Страница 4: ......

Страница 5: ...roviding Dedicated Links for Fast Ethernet 1 6 Network Configuration Sample 1 7 2 INSTALLING THE SYSTEM Before You Begin 2 1 Installing the System on a Table Top or in a Free Standing Stack 2 2 Installing the System in a Distribution Rack 2 3 Preparing the System and Rack 2 3 Mounting the System into a Distribution Rack 2 5 3 CABLING SWITCH 3900 PORTS Overview of Cabling 3 1 Fiber Safety Precautio...

Страница 6: ...OOTING THE SYSTEM Getting Additional Help 6 1 Diagnosing Problems 6 1 Power Failures 6 1 Abnormal LED Activity 6 1 Cleaning Dirty Fiber Optic Ports and Connectors 6 4 A SYSTEM SPECIFICATIONS B SITE REQUIREMENTS AND SAFETY CODES General Safety Requirements B 1 Wiring Closet Recommendations B 1 Distribution Rack Requirements B 2 Protective Grounding for the Rack B 2 Space Requirements for the Rack B...

Страница 7: ...edge of 3Com s Switch 3900 high performance networking equipment Most user guides and release notes are available in Adobe Acrobat Reader Portable Document Format PDF or HTML on the 3Com World Wide Web site http www 3com com Finding Specific Information in This Guide This table shows where to find specific information For information on Turn to Best ways to use the Switch 3900 system System Featur...

Страница 8: ...sonal injury For information on Turn to Table 2 Text Conventions Convention Description Screen displays This typeface represents information as it appears on the screen Commands The word command means that you must enter the command exactly as shown and then press Return or Enter Commands appear in bold Example To update the system software enter the following command system softwareUpdate This gu...

Страница 9: ... describes any changes to the Switch 3900 system s documentation SuperStack II Switch 3900 and 9300 Quick Installation Guide How to perform a quick installation of your system For more details on installation see the SuperStack II Switch 3900 Getting Started Guide SuperStack II Switch 3900 Getting Started Guide All the procedures necessary for getting your system up and running including informati...

Страница 10: ... system If you are using network management software from another vendor refer to the sections of the product s documentation that describe how to manage SNMP devices SNMP documents 3Com recommends these books for easy to read descriptions of SNMP Marshall T Rose The Simple Book An Introduction to Networking Management Englewood Cliffs NJ Prentice Hall 1996 Introduction to SNMP Self Study Guide Or...

Страница 11: ...Year 2000 Compliance 5 Year 2000 Compliance For information on Year 2000 compliance and 3Com products visit the 3Com Year 2000 Web page http www 3com com products yr2000 html ...

Страница 12: ......

Страница 13: ... II Switch 3900 family delivers full line rate nonblocking switching between 10 100 Mb links and 1000 Mb Gigabit Ethernet links The Switch 3900 family consists of two models 3C39024 The 24 port 10 100BASE TX switch with up to three Gigabit Ethernet links See Figure 1 1 3C39036 The 36 port 10 100BASE TX switch with up to three Gigabit Ethernet links See Figure 1 2 Both versions of the Switch 3900 p...

Страница 14: ...J 45 Ethernet ports System and Port LEDs Provide information about the system and each port 14 15 16 17 13 18 19 20 21 22 23 24 14 15 16 17 13 18 19 20 21 22 23 10 10 6 7 8 9 Status 1x 6x 12x 7x 13x 18x 24x 19x green enabled link OK flashing green disabled link OK off link fail Power Fault 10 100 BASE TX 2 3 1 11 12 4 5 6 7 8 9 2 3 1 11 12 4 5 24 Pckt Stat Pckt Stat Super Stack II Switch 3900 ...

Страница 15: ...ed link OK off link fail Power Fault 10 100 BASE TX Pckt Stat Pckt Stat Pckt Stat 2 3 1 10 11 12 4 5 6 7 8 9 2 3 1 10 11 12 4 5 6 7 8 9 14 15 16 17 13 18 19 20 21 22 23 24 14 15 16 17 13 18 19 20 21 22 23 24 26 27 28 29 25 30 31 32 33 34 35 36 26 27 28 29 25 30 31 32 33 34 35 36 Super Stack II Switch 3900 Ethernet Ports Provide 36 10 100BASE TX RJ 45 Ethernet ports System and Port LEDs Provide inf...

Страница 16: ...lows you to connect a workstation or modem to the Switch 3900 system for management access 1000 Base SX Pckt Stat Console RPS Connector Connects to the Optional Redundant Power System Optional Gigabit Ethernet Slots Allow you to add additional Gigabit Ethernet modules Fixed Gigabit Ethernet Port Provides a 1000BASE SX link Gigabit Ethernet Port LEDs Provide information on the port status and activ...

Страница 17: ...it IGMP Snooping The Switch 3900 conserves the network bandwidth that is consumed by audio and video applications by keeping IP multicast traffic isolated to specific ports Trunking links Spanning Tree and Advanced Redundant Power Supply RPS support The Switch 3900 protects against cable and equipment failures with Spanning Tree Protocol and trunking links The optional RPS protects against power i...

Страница 18: ... LX Gigabit Ethernet Module Installation Guide that is on the Documentation CD and shipped with either module Network Configuration Example This section describes one way to place the Switch 3900 in your network to alleviate traffic congestion Providing Dedicated Links for Fast Ethernet The rapid deployment of Fast Ethernet has increased bandwidth demand many times over not only by supporting 100 ...

Страница 19: ... desktop systems Status 1x 6x 12x 7x 13x 18x 24x 19x 25x 30x 36x 31x green enabled link OK flashing green disabled link OK off link fail Fault Power 10 100 BASE TX 2 3 1 10 11 12 4 5 6 7 8 9 2 3 1 10 11 12 4 5 6 7 8 9 14 15 16 17 13 18 19 20 21 22 23 24 14 15 16 17 13 18 19 20 21 22 23 24 26 27 28 29 25 30 31 32 33 34 35 36 26 27 28 29 25 30 31 32 33 34 35 36 Pckt Stat Pckt Stat Pckt Stat Super St...

Страница 20: ......

Страница 21: ...fore You Begin the next section Installing the System in a Distribution Rack on page 2 3 Before You Begin Before you begin this procedure be sure to Move the Switch 3900 system close to where you plan to install it Install the system near an easily accessible power outlet You can power down the system only by removing the power cord from the power source Have a No 1 Phillips screwdriver available ...

Страница 22: ...lashing green disabled link OK off link fail Fault Power 10 100 BASE TX 2 3 1 10 11 12 4 5 6 7 8 9 2 3 1 10 11 12 4 5 6 7 8 9 14 15 16 17 13 18 19 20 21 22 23 24 14 15 16 17 13 18 19 20 21 22 23 24 26 27 28 29 25 30 31 32 33 34 35 36 26 27 28 29 25 30 31 32 33 34 35 36 Pckt Stat Pckt Stat Pckt Stat Status 1x 6x 12x 7x 13x 18x 24x 19x 25x 30x 36x 31x green enabled link OK flashing green disabled li...

Страница 23: ...he power source Preparing the System and Rack To prepare the system and distribution rack for installing the Switch 3900 system 1 See Appendix B for distribution rack requirements 2 Attach the mounting brackets to the left and right sides of the system using the M4 x 10 mounting bracket screws See Figure 2 2 Figure 2 2 Installing System Mounting Brackets 3 Locate the top of a universal mounting ho...

Страница 24: ...ole pattern Figure 2 4 illustrates the positions of two Switch 3900s one attached to holes 1 and 4 and the other attached to holes 6 and 9 To mount only one Switch 3900 use either position Figure 2 4 Placement of Switch 3900s in a Distribution Rack 5 Repeat the process on the other rail Be sure to select holes that are parallel to each other on the mounting rails Top of the pattern or top of the r...

Страница 25: ... the system in place Insert the four suitable mounting screws not provided into the designated mounting holes on the bracket Repeat for the other side 3 Verify that the system is level 4 Tighten the mounting screws The system is now installed in the distribution rack Figure 2 6 shows two Switch 3900 systems installed in a distribution rack Figure 2 6 Two Systems Installed in a Rack You are now rea...

Страница 26: ......

Страница 27: ... 24 or 36 shielded 10 100BASE TX RJ 45 Ethernet ports on the front panel One fixed Gigabit Ethernet port on the back panel Two Gigabit Ethernet expansion slots for optional Gigabit Ethernet modules on the back panel Fiber Safety Precautions SuperStack II Switch 3900 modules use lasers in their fiber optic ports To ensure your safety when you install or work with these modules comply with the follo...

Страница 28: ...ir wiring To connect a Switch 3900 system to a 10 100BASE TX repeater or switch use a crossover cable or set the port on the connected device to MDI and use a straight through cable Follow these guidelines when you cable 10 100BASE TX connectors Use two twisted pair wires for each link Use twisted pair wire that is 22 26 AWG 0 5 millimeter in diameter Use twisted pair wire with an impedance of bet...

Страница 29: ...ctor Pin Assignments Table 3 1 provides the pin assignments for the RJ 45 connectors Male RJ 45 connector 10 100BASE TX cable Port 7 1x 6x 12x 7x 13x 18x 24x 19x 25x 31x 10 100 BASE TX Table 3 1 10 100 BASE TX RJ 45 Pin Assignments Pin No Signal Description 1 RX Receive 2 RX Receive 3 TX Transmit 4 Not used 5 Not used 6 TX Transmit 7 Not used 8 Not used ...

Страница 30: ...tors Verify that the length of the fiber cable from the system to any location does not exceed these recommended distances Use 1000BASE LX over 8 micron to 10 micron SMF fiber for distances of up to 3 kilometers 1 86 miles Use 1000BASE SX over 62 5 micron MMF fiber for distances of up to 260 meters 852 feet Use 1000BASE SX over 50 micron MMF fiber for distances of up to 525 meters 1722 feet Each G...

Страница 31: ...hrough 3 Figure 3 2 shows the Gigabit Ethernet cabling Figure 3 2 Cabling the Fixed Gigabit Ethernet Port Cabling the Console Port The Console port on the back panel provides local or remote administration For Local Administration The Console port provides a DB 9 connection to a local terminal or workstation that runs a terminal emulation program and acts as the Console For Remote Administration T...

Страница 32: ...o your terminal Figure 3 3 shows the cabling of the Console port You can also access the system remotely through any Ethernet port using telnet See the SuperStack II Switch 3900 and 9300 Administration Guide To use the Administration Console to configure the system for management access through the Console port see Chapter 5 Figure 3 3 Cabling the Console Port DB 9 connector 1000 Base SX Pckt Stat...

Страница 33: ...ssignments for the Console port Table 3 2 Console Port DB 9 Pin Assignments Pin No Signal Description 1 DCD Data Carrier Detect 2 RDA Received Data 3 TD Transmitted Data 4 DTR Data Terminal Ready 5 GND Signal Ground 6 DSR Data Set Ready 7 RTS Request To Send 8 CTS Clear To Send 9 Not used ...

Страница 34: ......

Страница 35: ...stem To protect against internal power supply failures you can connect a 3Com Advanced Redundant Power System Type 2 RPS to the Switch 3900 system The RPS connector is located on the rear panel CAUTION Connect only a 3Com Advanced Redundant Power System Type 2 to this connector using the external Type 2 Y cable that is shipped with the RPS For details follow the installation instructions and safet...

Страница 36: ...essible You can turn the system off only by removing the power cord from the power source 2 Plug the power cord into the system 3 Plug the other end of the power cord into the power outlet The LEDs provide information while the system runs power up diagnostics Power up Diagnostics The Switch 3900 system runs diagnostic software at power up This software verifies that the system works before you ad...

Страница 37: ...rational Solid or Blinking Yellow The system has failed diagnostics or some other operational error has occurred See Chapter 6 for troubleshooting information Ethernet Port Diagnostics This section summarizes the information displayed by the port LEDs Packet LED Activity No Light Data is not passing through the port Blinking Yellow Data is passing through the port Yellow Data is passing through th...

Страница 38: ...3 18 19 20 21 22 23 24 14 15 16 17 13 18 19 20 21 22 23 24 26 27 28 29 25 30 31 32 33 34 35 36 26 27 28 29 25 30 31 32 33 34 35 36 Pckt Stat Pckt Stat Pckt Stat Ethernet Port Status LEDs Green Associated port is active Flashing Green Port active but disabled OFF Port disabled Fault Solid or Blinking Yellow System failed at power up Power Green System powered on Ethernet Port Packet LEDs Yellow Por...

Страница 39: ...Chapter 5 Table 4 1 System Power Up Checklist Check Description Power up error messages If there is a problem during power up the messages are displayed in the Administration Console connection through the Console port Normal LED activity When the power up diagnostics are running the LEDs light in a certain pattern as described in the Power up Diagnostics section After you properly cable the syste...

Страница 40: ......

Страница 41: ...itch 3900 and 9300 Administration Guide For more complete network management access the system with an external SNMP based management application such as 3Com s Transcend Enterprise Manager for UNIX or Windows or another network management application How Do You Want to Manage the System You can manage your system locally through a terminal connection or through the network with an IP connection T...

Страница 42: ... 3900 system and a subnetwork It allows you to manage the system through any of the Ethernet ports With an IP interface you can use the rlogin or telnet commands to access the Administration Console using TCP IP from a host computer You can also use the IP interface to manage the system with an external management application Initial Management Access The first time that you access your system you...

Страница 43: ...nformation on how to define an IP interface through which you can manage your Switch 3900 system An IP interface contains the following parameters IP address This address which is specific to your network is used to manage the system The IP address defines both the number of the network to which the interface is attached and its host number on that network Subnet mask This 32 bit number uses the s...

Страница 44: ......

Страница 45: ...e of purchase Software revision number Brief description of the problem You can view some of this information in the Administration Console From the top level menu enter system display For additional information and phone numbers see Appendix C Diagnosing Problems By observing system diagnostics you can identify and correct problems that might occur when the system powers up Power Failures If the ...

Страница 46: ... using an RPS or a UPS check that it is firmly plugged into the building s power outlet 4 Try another power cable 5 If the system still does not operate contact 3Com Technical Support or your service representative Table 6 2 Troubleshooting Abnormal System LED Activity LED Status Possible Sources of the Problem Steps to Take Fault LED blinks yellow Diagnostic software is not running 1 Check the Ad...

Страница 47: ... a connection to the port Cable is not fully attached to the port Port cable is faulty Fiber optic ports or connectors are dirty 1 Verify that all cables are firmly plugged into both the system s affected port and the attached device 2 Test for faulty cables 3 Clean the fiber optic ports and connectors See next section When the problem is corrected the LED lights green If the LED still does not li...

Страница 48: ...ng with fiber optic components To clean a fiber optic lens take these steps 1 Remove any accumulated dust or debris from the port or connector by blowing across all surfaces with a canned air duster Compressed gas is recommended such as Chemtronics Ultrajet or the Triangle Tool Group s Liqui Tool Dust A Way Do not use commercial compressed air or house air because of the risk of oil contamination ...

Страница 49: ... General Approval Statement The SuperStack II Switch 3900 is manufactured to the international Safety Standard EN60950 and is approved in the UK under the General Approval Number NS G 12345 J 100003 for indirect connection to the public telecommunication network Designed to Comply with IEC 950 Electromagnetic Emissions Agency Certification Meets FCC part 15 Subparagraph J Class A limits and CISPR ...

Страница 50: ... RFC 768 IP RFC 791 ICMP RFC 792 TCP RFC 793 ARP RFC 826 Table A 3 LED Indicators on the SuperStack II Switch 3900 LED Type Description System LEDs Power Green System is on Off System is receiving no power Fault Off System is operational Solid or Blinking Yellow System failed diagnostics or some other operational failure has occurred Port LEDs Stat Off Port is off line Blinking Green Port is onlin...

Страница 51: ... All grounding requirements listed in Wiring Closet Recommendations and Distribution Rack Requirements Wiring Closet Recommendations The cabling system plan at your facility probably covers most wiring closet concerns 3Com also recommends that you check these items Verify that your wiring closet meets all of the requirements in your facility cabling plan Verify that your wiring closet and your fac...

Страница 52: ...owered up Distribution Rack Requirements If you plan to mount your SuperStack II Switch 3900 systems in a distribution rack verify that your rack meets the basic mechanical and space requirements described in this section Protective Grounding for the Rack To ensure that voltages induced into wiring by lightning or other disturbances are directed to ground ground your distribution racks properly Us...

Страница 53: ...nce and provide excellent ventilation Use a rack that has the universal mounting rail hole pattern identified in IEC Standard 297 See Figure 2 3 for a description of the universal mounting hole pattern Use a rack that is made of steel Install equipment in the lower half of the distribution rack to avoid making it top heavy Use a rack that supports approximately 272 kg 600 lb Use a rack that has ad...

Страница 54: ...ation The following lists are provided as resources to help you to find additional information Building Codes Major building codes Uniform Building Code International Conference of Building Officials ICBO 5360 South Workman Mill Road Whittier CA 90601 2298 BOCA Basic Building Code Building Officials and Code Administrators BOCA International Inc 4051 West Flossmoor Road Country Club Hills IL 60478...

Страница 55: ...and capability of electrical wiring and equipment to determine whether they meet certain safety standards when properly used Acceptance is usually indicated by the words UL Approved or UL Listed UL 333 Pfingsten Road Northbrook IL 60062 2096 National Electrical Manufacturers Association NEMA An organization of electrical product manufacturers Members develop consensus standards for cables wiring a...

Страница 56: ......

Страница 57: ... browser http www 3com com This service provides access to online support information such as technical documentation and software library as well as support options ranging from technical education to maintenance and professional services 3Com FTP Site Download drivers patches MIBS and software across the Internet from the 3Com public FTP site This service is available 24 hours a day 7 days a wee...

Страница 58: ...ervices including network planning installation hardware maintenance application training and support services When you contact your network supplier for assistance have the following information ready Product model name part number and serial number A list of system hardware and software including revision levels Diagnostic error messages Details about recent configuration changes if applicable I...

Страница 59: ...8 515 86 21 6350 1590 10 800 3656 800 933 486 61 2 9937 5085 001 800 61 009 0031 61 6439 1800 801 777 0800 446 398 continued Singapore S Korea From anywhere in S Korea From Seoul Taiwan Thailand Pakistan Philippines 800 6161 463 82 2 3455 6455 00798 611 2230 0080 611 261 001 800 611 2000 61 2 9937 5085 1235 61 266 2602 Europe From anywhere in Europe call 31 0 30 6029900 phone 31 0 30 6029999 fax F...

Страница 60: ...ddle East 011 44 1442 435860 011 44 1442 435718 From the following European countries you may call the toll free numbers select option 2 and then option 2 Austria Belgium Denmark Finland France Germany Hungary Ireland Israel Italy Netherlands Norway Poland Portugal South Africa Spain Sweden Switzerland U K 06 607468 0800 71429 800 17309 0800 113153 0800 917959 0130 821502 00800 12813 1 800 553117 ...

Страница 61: ...n 4 Console port baud setting 5 2 cabling 3 5 default settings 5 2 pin assignments 3 7 terminal 5 1 conventions in text defined 2 cooling the system B 2 D DB 9 connector pin assignments 3 5 diagnostic signs 6 1 to 6 3 distribution rack preparing for system installation 2 3 requirements B 2 universal mounting hole pattern 2 4 documentation comments 4 for the Switch 3900 system 3 documents on CD ROM...

Страница 62: ...rnet 3 4 mounting brackets 2 3 mounting hole pattern 2 3 mounting rails B 3 multimode fiber safety precautions 3 1 N National Fire Protection Association NFPA B 5 NEC electrical code B 5 NEMA electrical code B 5 network supplier support C 2 notes in text defined 2 O online technical services C 1 P pin assignments 10 100BASE TX RJ 45 connectors 3 3 Console port 3 7 ports fiber optic safety 3 1 powe...

Страница 63: ... 4 1 turning on 4 1 4 2 Switch 3900 documentation 3 system checks 4 5 system cooling B 2 T table top installation 2 2 technical support 3Com URL C 1 bulletin board service C 1 fax service C 2 FTP site C 1 network suppliers C 2 product repair C 4 temperature specifications A 1 transceiver fiber optic safety precautions 3 1 troubleshooting port LED activity 6 3 power failures 6 2 system checks 4 5 s...

Страница 64: ......

Страница 65: ...ly to Heritage US Robotics Corporation products If it appears that any such product does not perform properly with regard to such date data on and after January 1 2000 and Customer notifies 3Com before the later of April 1 2000 or ninety 90 days after purchase of the product from 3Com or its authorized reseller 3Com shall at its option and expense provide a software update that would effect the pr...

Страница 66: ...LITY OF SUCH DAMAGES AND LIMITS ITS LIABILITY TO REPAIR REPLACEMENT OR REFUND OF THE PURCHASE PRICE PAID AT 3COM S OPTION THIS DISCLAIMER OF LIABILITY FOR DAMAGES WILL NOT BE AFFECTED IF ANY REMEDY PROVIDED HEREIN SHALL FAIL OF ITS ESSENTIAL PURPOSE DISCLAIMER Some countries states or provinces do not allow the exclusion or limitation of implied warranties or the limitation of incidental or conseq...

Отзывы: