background image

 
 

3B SCIENTIFIC

®

 PHYSICS 

 

 
 

3B Netlog™ 

1000539 (115 V, 50/60 Hz) 
1000540 (230 V, 50/60 Hz) 

 

Instruction manual  

06/14 MEC 

 

 

1. Safety instructions  

To guarantee the safe functioning of the 
3B NET

log

™ equipment, it is necessary to 

abide by the following instructions:  

 

Do not connect the 3B NET

log

™ device to 

a voltage in excess of ±20V or current in 
excess of ±2A.  

 

Make sure the 3B NET

log

™ device does 

not come into contact with water.  

 

The 3B NET

log

™ device should not be 

exposed to temperatures above 80°C. 

The operating voltage input is protected 
against polarity reversal. However, it is not 
protected against excess voltage.  

 

Do not apply voltage in excess of 4.5V to 
the operating voltage input.  

 

2. Scope of delivery  

1 3B 

NET

log

™ device 

Power supply unit (4.5V DC, 300mA)  

USB cable  

1 Installation 

CD 

 

3. Introduction  

3B NET

log

™ is a multimedia data acquisition 

and evaluation system for current and voltage 
measurements and for measurements using 
sensors. The system can be used with or with-
out being connected to a computer. With the 
accompanying 3B NET

lab

™ software, meas-

urements can be conducted with arbitrarily 
chosen parameters as well as in prepared 
experiments. The prepared experiments take 
the user through an interactive experimental 
environment where the measurement parame-
ters have already been defined. When used 
within a network, the teacher and students can 
mutually monitor their results.    
Without being connected to a computer, the 
3B NET

log

™ device can be used as a digital 

multimeter for current and voltage measure-
ments. Combined with different sensors, the 
3B NET

log

™ equipment can also be used as a 

handheld unit with automatic sensor recogni-
tion.  

 
 

Содержание 1000539

Страница 1: ... supply unit 4 5V DC 300mA 1 USB cable 1 Installation CD 3 Introduction 3B NETlog is a multimedia data acquisition and evaluation system for current and voltage measurements and for measurements using sensors The system can be used with or with out being connected to a computer With the accompanying 3B NETlab software meas urements can be conducted with arbitrarily chosen parameters as well as in ...

Страница 2: ...Resolution 12 bit 4 3 Digital inputs Channels 4 separated into 2 TTL inputs one of which is a high speed time input plus 2 in puts via optocoupler Sampling rate 50k samples s 100k samples s high speed time input Connection 8 pin mini DIN socket 4 4 Digital outputs Channels 6 Signal TTL Connection 8 pin mini DIN socket 4 5 Additional data Computer connection USB Internal data memory 128k Display 64...

Страница 3: ...ion of measurement parameters for channels A and B Changing between fields while setting the time and date Return to previous menu 5 3 Measurement parameters Name Significance VdcA DC voltage on channel A VacA AC voltage on channel A Idc DC current on channel A Iac AC current on channel A VdcB DC voltage on channel B VacB AC voltage on channel B Bin Binary representation 5 4 Connection of sensors ...

Страница 4: ... hardware manager under Control Panel Hardware and Sound Hard ware Manager Double click USB Controller in the hard ware manager Double click USB Serial Converter Click Drivers Update Driver A small window will open so that you can search for the driver software Click Find driver software on this computer in the window Click the Browse button and select the path for the driver Follow the instructio...

Страница 5: ...te Switch on the 3B NETlog device by pressing the On Off button Press the Date Time three times the date field will appear on the display Press the Store button the input field for SET DATE will appear on the display Specify the desired date in the input field by pressing the Rate or Store button and use the Channel button to skip be tween the year month and day fields Confirm by pressing the Date...

Страница 6: ...n the 3B NETlog memory can be retrieved and saved as text files with the help of the 3B NETdata software In addition the software also provides the capability to set modes of measurement and measurement parameters Note Only one interface 3B NETlog may be connected to the computer when using the software 3B NETdata 9 1 Installation of the driver Before installing the 3B NETlab software it is necess...

Страница 7: ...ntire memory of the instrument Quit exits the program 9 4 Reading and saving measurement data Reading and saving measured data with the 3B NETlog equipment Connect the 3B NETlog equipment to a computer via USB cable Start 3BNETdata and click on the tab Read Data Press Read and wait till the progress bar reaches 100 Select the measurements you wish to be saved from the list on the left Select colum...

Страница 8: ...ce Press Test again and if neces sary refresh by pressing F5 13 Support If you have any queries and or suggestions please feel free to contact our support team Email support 3bnetlog com Internet http www 3bnetlog com 14 The CE marking 3B NETlog conforms to the requirements of these EU specifications EN 61010 1 Protoype tested EN 61326 1 Tested for noise im munity and interference Conformity with ...

Отзывы: