background image

 

A small window will open so that you can 
search for the driver software. Click "

Find 

driver software on this computer"

 in the 

window. 

 

Click "

Select from a list of device drivers on 

this computer"

 

Click the "

Medium…"

 button. 

 

Click the "

Browse…"

 button and select the 

path for the driver. 

 

Click “Yes” to confirm that the file should 
be overwritten.   

 

7.2 Software installation  

Note on installing the software   
For this software, please refer to the installa-
tion instructions available in the 3B NET

lab

™ 

software manual.  

 
 

8. Operating without a computer  

Operating a 3B NET

log

™ device without a 

computer is achieved by using the buttons on 
the operating panel. The functions of these 
buttons may change according to the operation 
being undertaken.  

 

 

Note:

 a menu selection can be can-

celled at any time by using the
Channel 

← 

button.  

 

8.1  Battery level and temperature display  

 

Switch on the 3B NET

log

™ device by 

pressing the 

On/Off 

button.  

 

Press the 

Date/Time

 

 button.  

The following should appear on the display:  
e.g.: 

BATTERY: 100%  

        

TEMP.:  22.0°C  

 

8.2  Setting the time  

 

Switch on the 3B NET

log

™ device by 

pressing the 

On/Off

 button.  

 

Press the 

Date/Time

 

↵ 

button twice (the 

time field will appear on the display). 

 

Press the 

Store

 

 button (the input field for 

SET TIME will appear on the display). 

 

Specify the desired time in the input field 
by pressing the 

Rate

 

 or the 

Store

 

 but-

ton and use the 

Channel

 

 button to skip 

between the hours, minutes and seconds 
fields.  

 

Confirm by pressing the 

Date/Time

 

 but-

ton.  

 

8.3  Setting the date  

 

Switch on the 3B NET

log

™ device by 

pressing the 

On/Off

 button.  

 

Press the 

Date/Time

 

 three times (the 

date field will appear on the display). 

 

Press the 

Store

 

 button (the input field for 

SET DATE will appear on the display). 

 

Specify the desired date in the input field 
by pressing the 

Rate

 

 or 

Store

 

 button 

and use the 

Channel

 

 button to skip be-

tween the year, month and day fields.  

 

Confirm by pressing the 

Date/Time

 

 but-

ton.  

 

8.4 Application as a handheld device for 

measuring current and voltage  

 

Set up the 3B NET

log

™ equipment.  

 

Connect the voltage/current input of chan-
nel A or B, as desired.  

 

If necessary, disconnect any sensor which 
might be connected to the same channel.  

Setting and selecting measurement parame-
ters:  

 

Press the 

Channel

 

 button (the menu 

DISPLAY SIGNAL 1 will appear on the 
display).  

 

Select the desired measurement parame-
ter with the 

Rate

 

 or 

Store

 

 button.  

 

Select the mode of operation with the 

Date/Time

 

 button (the menu RANGE 

SIGNAL 1 will appear on the display).  

 

Select the desired mode of operation with 
the 

Rate

 

 or 

Store

 

 button.  

 

Confirm this selection with the 

Date/Time

 

 

button (the menu DISPLAY SIGNAL 2 will 
appear on the display).  

 

Select the desired measurement parame-
ter with the 

Rate

 

 or 

Store

 

 button.  

 

Select the desired mode of operation with 
the 

Rate

 

↑ 

or 

Store

 

 button.  

 

Confirm the selection with the 

Date/Time

 

↵ 

button (a dot will appear in 

front of the respective measurement pa-
rameter when operating manually).  

The 3B NET

log

™ device is ready to conduct 

measurements.  

 

8.5  Application as  a handheld measuring 

device with sensors  

 

Set up the 3B NET

log

™ equipment.  

 

Connect the sensor to the relevant input 
and remove the connections of the 4-mm 
sockets from the same channel.   

Содержание 1000539

Страница 1: ... supply unit 4 5V DC 300mA 1 USB cable 1 Installation CD 3 Introduction 3B NETlog is a multimedia data acquisition and evaluation system for current and voltage measurements and for measurements using sensors The system can be used with or with out being connected to a computer With the accompanying 3B NETlab software meas urements can be conducted with arbitrarily chosen parameters as well as in ...

Страница 2: ...Resolution 12 bit 4 3 Digital inputs Channels 4 separated into 2 TTL inputs one of which is a high speed time input plus 2 in puts via optocoupler Sampling rate 50k samples s 100k samples s high speed time input Connection 8 pin mini DIN socket 4 4 Digital outputs Channels 6 Signal TTL Connection 8 pin mini DIN socket 4 5 Additional data Computer connection USB Internal data memory 128k Display 64...

Страница 3: ...ion of measurement parameters for channels A and B Changing between fields while setting the time and date Return to previous menu 5 3 Measurement parameters Name Significance VdcA DC voltage on channel A VacA AC voltage on channel A Idc DC current on channel A Iac AC current on channel A VdcB DC voltage on channel B VacB AC voltage on channel B Bin Binary representation 5 4 Connection of sensors ...

Страница 4: ... hardware manager under Control Panel Hardware and Sound Hard ware Manager Double click USB Controller in the hard ware manager Double click USB Serial Converter Click Drivers Update Driver A small window will open so that you can search for the driver software Click Find driver software on this computer in the window Click the Browse button and select the path for the driver Follow the instructio...

Страница 5: ...te Switch on the 3B NETlog device by pressing the On Off button Press the Date Time three times the date field will appear on the display Press the Store button the input field for SET DATE will appear on the display Specify the desired date in the input field by pressing the Rate or Store button and use the Channel button to skip be tween the year month and day fields Confirm by pressing the Date...

Страница 6: ...n the 3B NETlog memory can be retrieved and saved as text files with the help of the 3B NETdata software In addition the software also provides the capability to set modes of measurement and measurement parameters Note Only one interface 3B NETlog may be connected to the computer when using the software 3B NETdata 9 1 Installation of the driver Before installing the 3B NETlab software it is necess...

Страница 7: ...ntire memory of the instrument Quit exits the program 9 4 Reading and saving measurement data Reading and saving measured data with the 3B NETlog equipment Connect the 3B NETlog equipment to a computer via USB cable Start 3BNETdata and click on the tab Read Data Press Read and wait till the progress bar reaches 100 Select the measurements you wish to be saved from the list on the left Select colum...

Страница 8: ...ce Press Test again and if neces sary refresh by pressing F5 13 Support If you have any queries and or suggestions please feel free to contact our support team Email support 3bnetlog com Internet http www 3bnetlog com 14 The CE marking 3B NETlog conforms to the requirements of these EU specifications EN 61010 1 Protoype tested EN 61326 1 Tested for noise im munity and interference Conformity with ...

Отзывы: