MAINS FUSE
PRED-PSU-SM-HMA
MAINS FUSE = 2AF
MAINS input
100 - 240Vac
Io Vo
Adj Adj
PRED-PSU-SM-HMA
30Vdc
0V
255 x 180 x 100mm
Enclosure Dimensions
PRED-PSU-SM-HMA_v3
This PSU is compatible with the following products: PREDATOR HMA
SAFETY:
Isolate mains supply while installing.
FIXING:
Securely fix the PSU with suitable fixings.
GLANDS:
Face downwards, unused glands must be sealed.
ELECTRICAL CONNECTIONS:
Connecting the mains power.
MAINS INPUT
100-240Vac
L=LIVE (BROWN)
100-240Vac 50/60Hz
E=EARTH (GREEN/YELLOW)
N=NEUTRAL (BLUE)
SAFETY: ENSURE MAINS INPUT AND EARTH CONNECTIONS ARE SECURELY CONNECTED AND STRAIN
RELIEVED.
FUSE PROTECTION: Mains input fuse 2AF.
Model Number: PRED-PSU-SM-HMA
Serial Number: yymmndd-xxxx
Input Voltage: 100 – 240V AC 50/60Hz
Input Current: 2.1A
Output Voltage: 30V DC
Output Current: 6.2A
360Vision Technology, 7 Seymour Court Manor Park,
Runcorn, Cheshire, WA7 1SY, Tel +44 (0)1928 570000.
www.360visiontechnology.com
L
E
N
PRED-PSU-SM-HMA
Safety and Installation Sheet
360Vision Technology, 7 Seymour Court Manor Park, Runcorn, Cheshire, WA7 1SY, Tel +44 (0)1928 570000.
www.360visiontechnology.com
Predator Installation Manual V10_1_29_00
Page 20 of 56
© 360 Vision Technology Ltd
Содержание Predator
Страница 16: ...Predator Installation Manual V10_1_29_00 Page 16 of 56 360 Vision Technology Ltd ...
Страница 28: ...Predator Installation Manual V10_1_29_00 Page 28 of 56 360 Vision Technology Ltd ...
Страница 33: ... See Browser page 50 Predator Installation Manual V10_1_29_00 Page 33 of 56 360 Vision Technology Ltd ...
Страница 35: ...16 Status Predator Installation Manual V10_1_29_00 Page 35 of 56 360 Vision Technology Ltd ...
Страница 38: ...Predator Installation Manual V10_1_29_00 Page 38 of 56 360 Vision Technology Ltd ...
Страница 56: ...Predator Installation Manual V10_1_29_00 Page 56 of 56 360 Vision Technology Ltd ...