26
Hardware Interface
LTC Time Code Output
An LTC time code output is provided on the
LTC OUT
BNC connector. It may be
selected by means of the On-Screen user interface to output time code from any of the three
video channels during playback. The LTC output has a source impedance of <5 ohms.
Keyboard
Attach the alphanumeric keyboard to the purple 5-pin
KEYBD
connector to control the
server and manage clips with the On-Screen graphic user interface. Note that the server will
only recognize the keyboard if it is attached before power up.
Mouse
A two-button scroll mouse is provided with the Image Server. Plug the mouse into the
green 5-pin
MOUSE
port. Do not use the USB ports, even if the supplied mouse is USB
capable. Note that the server will only recognize the mouse if it is attached before power up.
Monitor
A VESA-compliant computer monitor may be connected to the 15-pin VGA video port.
The Image Server resolution is fixed at 1024 x 768 pixels, with a refresh rate of 72 Hz. This is
best-viewed on 17-inch or larger monitors. 360 Systems does not provide monitors for the
server. Note: Do not use older monitors that are not VESA compliant. The server may not start
properly if an unsuitable monitor is connected.
Serial Port
The system board serial port is not used. Make no connection.
USB Ports
The system board USB ports are not used. Make no connection.
Power
An IEC mains socket is provided on the rear panel for power input. The Image Server
will accept world-wide power sources in the range of 100-240 volts AC, 50-60 Hz. The server
is shipped with a power cord appropriate for the region in which it is sold. Replace the power
cord only with one of the same type and rating.
DO NOT use the power supply switch to shutdown the Image Server.
Shutdown the
system only by momentarily pressing the front panel power button, or through the HALT
command on the On-Screen user interface. The rear panel power switch should only be used
if the Image Server fails to shutdown after holding the front panel power switch for 4 seconds.
The rear panel power switch can be used to prevent the application of power during service
procedures once the normal shutdown sequence has completed.
The server may also be shut down from the graphic user interface. Click
START>SHUTDOWN>SHUTDOWN. After a few seconds, shutdown will occur.
Содержание MAXX
Страница 1: ......
Страница 48: ...46 Basic Operations Page intentionally left blank ...