2N TELEKOMUNIKACE a.s., www.2n.cz
40/72
Parameter
(function)
Parameter
Name
Range
Default
Note
943
Maximum
busy tone or
pause
duration
0–255
70 = 0,7
s
944
Maximum
tone-pause
difference
0–255
10 = 0,1
s
945
Minimum
count of
busy tone
periods
2×9
4
946
Dual tone
detection
setting
0–10
4 = 440
Hz
All continuous, busy and ringing tones are
detected. Dual tones are detected if one of
their components is between 400 and 500
Hz. If both components are in this range, set
a lower detection value. Set 0 for 400 Hz and
10 for 500 Hz.
This setting does not affect the single tone
detection, which always works between 300
and 550 Hz.
951
Minimum
ringing tone
time
1–200
50 = 0,5
s 2)
The longest ringing period pause must be in
the interval between parameters 952 and
953.
Warning! As these parameters also
detect incoming calls, an incorrect setting
may result in the intercom not answering the
call!
952
Minimum
long pause
time
5–100
10 = 1 s