background image

  8

 

Setting the parameters and access rights using the PC 

The 

APS mini Reader

 setup program is 

designed for operating systems Windows 95, 
Windows NT 4.0 and higher versions; it does 
not require installation. It is designed for offline 
mode of the readers and allows for 
programming of operation parameters on the 
individual 2N APS mini modules connected on 
the data bus RS485. It cannot be used for 
access right programming. To connect the 
modules to a PC you need either 
RS485/RS232 (or alternatively RS485/USB) 
communication converter with automatic 
switching of the direction of communication or 
an RS485/Ethernet converter with the following 
settings: 8 data bits, even parity, 19 200 bps 
and 1 stop bit.  

 

 

The main menu of the program includes the following commands: 

 Program 

Æ

 Setup … displays the screen for setup of the PC communication port and 

the service card code,  

  Start / Stop … PC-module communication control, 

  Write … writes the configuration of the general properties in the reader module, 

 Program 

Æ

 End … ends the program. 

 

The program desktop is divided into 3 parts: 

  The area for the reader module status visualization (used for verification of the correct 

connection of the module). 

  Area for HW address setup, 

  Area with controls for the setup of general properties of the module. 

 

The following indicators are located in the status line (from the left):

 

 PC-module communication status (red color indicates communication errors, 

communication without errors is indicated by green color), 

 Operation parameters writing progress, 

  Verbal description of the communication status.  

 
 
 
 
 

Содержание APS Mini

Страница 1: ...2N APS MINI Standalone Reader Module Order No 9134162WE Reader Module with Attendance Keypad Order No 9134167WE User and Service manual Version 2 1 ...

Страница 2: ...WE EntryCom set 9134162WE Standalone reader module 9134167WE Reader module with attendance keypad 91341612WE Build in reader module for EntryCom 91341631E RS485 Ethernet converter 9134164E PC mini reader 9134165E Chip card 9134166E Chip key fob ...

Страница 3: ...omously without the need to be connected to the PC After connecting to the PC the system offers more functions thanks to online status monitoring and to archiving of events from the connected reading modules The reading module integrating all circuits necessary for one reading place and one door is the basic hardware element of the APS mini access system Regimes of operation Autonomous programming...

Страница 4: ... in the memory 748 inputs 2x logical non potential Output for door lock 1x relay switch contact 2 A 24 V Alarm output Transistor output 5 V 5 mA Protective contact tamper Opto electrical Max reading distance Normally 8 cm with ISO cards Communication channel RS485 galvanic non separated Alternative data output WIEGAND configurable Signalization 2x LED piezzo buzzer Working temperature 25 60 C Max ...

Страница 5: ...rsion insert the enclosed square screw nut 2 and fasten the module on the wall It is recommended to place an installation box for connection of incoming cables on the other side of the wall or in highly secured area with in out readers Shut the cover and lock it using enclosed screw Removal of the module can be performed in reverse order ...

Страница 6: ...to keep the distance of at least 50 cm This distance can be negatively influenced by various metallic constructions in case of doubts it is recommended to carry out practical test on the spot before the final installation Proper functioning and the reading distance can also be influenced by metal surfaces close to the antenna Such objects absorb electromagnetic field and may disturb the antenna of...

Страница 7: ...the handle can be used with ball handle door configuration Connecting the mother board with data bus RS485 It is possible to connect the data line RS485 to the cables A B and 0V Up to 32 reading modules 2N APS mini can be connected to this data line which consists of three conductors Data bus must be connected with cables designed for data transfer shielded cables or cables with twisted pairs of c...

Страница 8: ... 200 bps and 1 stop bit The main menu of the program includes the following commands Program Æ Setup displays the screen for setup of the PC communication port and the service card code Start Stop PC module communication control Write writes the configuration of the general properties in the reader module Program Æ End ends the program The program desktop is divided into 3 parts The area for the r...

Страница 9: ... the program is carried out after communication was initiated and after the button Save was pressed Result of the action is shown by the progress indicator in the second part of the status bar Modules 2N APS mini in the online regime can be controlled via programs APS mini Administrator APS mini Events and APS mini ED These allow besides programming the parameters of the modules also setting acces...

Страница 10: ...ast card the reader will go to the normal operational regime by itself Erasing cards from the memory Step 1 Step 2 Step 3 After having read the programming card for erasing the reader is set to programming regime Read cards that are to be rid of the access rights in the entry place in question After c 15 s after the last card the reader will go to the normal operational regime by itself Erasing al...

Страница 11: ...2N TELEKOMUNIKACE a s Modřanská 621 143 01 Praha 4 Czech Republic tel 420 261 301 111 fax 420 261 301 999 e mail sales 2n cz www 2n cz 2008 2N TELEKOMUNIKACE a s Praha OV 1468 v 2 1 ...

Отзывы: