Recommendations for installation 

Reading module 2N APS mini uses passive RF/ID technology, sensitive to external RF 
disturbance. This disturbance may come via radiation from the surroundings or via supply 
cables. 
Therefore it is necessary to avoid installing modules close to possible sources of 
electromagnetic field, including for example computer monitors (distance at least 3m) and 
various home and industrial appliances. It is also better to use recommended power 
supply (linear) to reduce disturbance coming via the cables. 
Disturbance caused by external field is increasing with increasing intensity and with the 
frequency of this field approaching the operation frequency of the reading modules (125 
kHz). From this perspective it is also necessary to take into consideration mutual 
disturbing of the reading modules – for proper functioning of modules it is necessary to 
keep the distance of at least 50 cm. This distance can be negatively influenced by various 
metallic constructions (in case of doubts it is recommended to carry out practical test on 
the spot before the final installation). 
Proper functioning and the reading distance can also be influenced by metal surfaces 
close to the antenna. Such objects absorb electromagnetic field and may disturb the 
antenna of the module – also in this case we recommend practical test. 
 

Connecting the cables of the reading module 

Description of cables 

Color Purpose 

Red 

Power 10 ÷ 15V 

Red-blue 

Power 10 ÷ 15V 

Blue 0 

Green 0 

Black 

A cable of the RS 485 line 

White 

B cable of the RS 485 line 

Pink 

Alarm output (+5V in case of any alarm) 

Brown-green 

Wiegand DATA 1 

Green-white 

Wiegand DATA 0 

Yellow 

Input 1 (status of the door) 

Grey 

Input 2 (leaving button / contact of the handle) 

Grey-pink 

NC contact relay 

Brown 

C contact relay 

Violet 

NO contact relay 

 
Inputs of the reading module must be controlled by a non-potential contact; the “switched 
on” status is defined by the input connected to 0V. 

 

Содержание APS Mini

Страница 1: ...2N APS MINI Standalone Reader Module Order No 9134162WE Reader Module with Attendance Keypad Order No 9134167WE User and Service manual Version 2 1 ...

Страница 2: ...WE EntryCom set 9134162WE Standalone reader module 9134167WE Reader module with attendance keypad 91341612WE Build in reader module for EntryCom 91341631E RS485 Ethernet converter 9134164E PC mini reader 9134165E Chip card 9134166E Chip key fob ...

Страница 3: ...omously without the need to be connected to the PC After connecting to the PC the system offers more functions thanks to online status monitoring and to archiving of events from the connected reading modules The reading module integrating all circuits necessary for one reading place and one door is the basic hardware element of the APS mini access system Regimes of operation Autonomous programming...

Страница 4: ... in the memory 748 inputs 2x logical non potential Output for door lock 1x relay switch contact 2 A 24 V Alarm output Transistor output 5 V 5 mA Protective contact tamper Opto electrical Max reading distance Normally 8 cm with ISO cards Communication channel RS485 galvanic non separated Alternative data output WIEGAND configurable Signalization 2x LED piezzo buzzer Working temperature 25 60 C Max ...

Страница 5: ...rsion insert the enclosed square screw nut 2 and fasten the module on the wall It is recommended to place an installation box for connection of incoming cables on the other side of the wall or in highly secured area with in out readers Shut the cover and lock it using enclosed screw Removal of the module can be performed in reverse order ...

Страница 6: ...to keep the distance of at least 50 cm This distance can be negatively influenced by various metallic constructions in case of doubts it is recommended to carry out practical test on the spot before the final installation Proper functioning and the reading distance can also be influenced by metal surfaces close to the antenna Such objects absorb electromagnetic field and may disturb the antenna of...

Страница 7: ...the handle can be used with ball handle door configuration Connecting the mother board with data bus RS485 It is possible to connect the data line RS485 to the cables A B and 0V Up to 32 reading modules 2N APS mini can be connected to this data line which consists of three conductors Data bus must be connected with cables designed for data transfer shielded cables or cables with twisted pairs of c...

Страница 8: ... 200 bps and 1 stop bit The main menu of the program includes the following commands Program Æ Setup displays the screen for setup of the PC communication port and the service card code Start Stop PC module communication control Write writes the configuration of the general properties in the reader module Program Æ End ends the program The program desktop is divided into 3 parts The area for the r...

Страница 9: ... the program is carried out after communication was initiated and after the button Save was pressed Result of the action is shown by the progress indicator in the second part of the status bar Modules 2N APS mini in the online regime can be controlled via programs APS mini Administrator APS mini Events and APS mini ED These allow besides programming the parameters of the modules also setting acces...

Страница 10: ...ast card the reader will go to the normal operational regime by itself Erasing cards from the memory Step 1 Step 2 Step 3 After having read the programming card for erasing the reader is set to programming regime Read cards that are to be rid of the access rights in the entry place in question After c 15 s after the last card the reader will go to the normal operational regime by itself Erasing al...

Страница 11: ...2N TELEKOMUNIKACE a s Modřanská 621 143 01 Praha 4 Czech Republic tel 420 261 301 111 fax 420 261 301 999 e mail sales 2n cz www 2n cz 2008 2N TELEKOMUNIKACE a s Praha OV 1468 v 2 1 ...

Отзывы: