Installation manual 2N® Analog Vario
45
/
77
Parameter
(function)
Parameter Name
Range
Default
Note
904
Automatic
Multiple Number
Dialling type
0–4
0 = disabled
for all buttons
1 = loud with
confirmation
2 = silent with
confirmation
3 = SP without
confirmation 1)
4 = SP without
confirmation 1)
906
Ticking into call
0–12
0 = off
The called party
recognises better that
the incoming call is from
the intercom.
911
Count of rings
before incoming
call answering
1–99
2
Warning!!! No
connection is
established if a higher
value is entered than as
allowed in the PBX
ringing timeout!!!
912
Max. call duration
1–99
12 = 120 s
Range of 10 s – 990 s
913
Log-in timeout
1–99
3
3 = 30 seconds
915
Hang-up time
between calls
5–99
15 = 1,5 s
921
Code lock mode
0–1
1 = enabled
0 = disabled
1 = enabled
For details on these
functions
see the Keypad
Description.
922
Buttons replaced
by keypad
0–1
0 = disabled
923
Telephone mode
0–1
0 = disabled
924
Tone dialling
during call
0–1
0 = disabled
Содержание 9135110E
Страница 1: ...Installation manual 2N Analog Vario v 1 6 www 2n com ...
Страница 5: ...Installation manual 2N Analog Vario 5 77 Part No 9135130E Main unit 3 buttons ...
Страница 38: ...Installation manual 2N Analog Vario 38 77 ...
Страница 39: ...Installation manual 2N Analog Vario 39 77 ...
Страница 71: ...Installation manual 2N Analog Vario 71 77 3 6 Downloads Templates Nametags ...
Страница 74: ...Installation manual 2N Analog Vario 74 77 4 1 Obecné výkresy Surface mounting Flush mounting ...
Страница 77: ...Installation manual 2N Analog Vario 77 77 ...