background image

Digital Detection Module - Quick Guide 

 

www.2MTechnology.net 

The figure below shows the structure and cable of the dev 
prevail. 

Temperature sensor 

4-pin cable 

 

Overvoltage category (except cord/plug-connected equipment): 

Ⅱ 

 

Pollution degree of the intended environment: the operational 
environment should be with less dust to avoid the pollution of 
blackbody target. (Pollution degree 2) 

If  the  equipment  is  used  in  a  manner  not  specified  by  the  manufacturer,  the 
protection provided by the equipment may be impaired. 

2

 

Appearance and size 

The actual device appearance shall prevail. The figure below shows the device size. 

 

 

 

3

 

Structure and cable 

ice. The actual device shall 

 

 

 

 

 

 

 

 

 

 

 

 

 

(3.4” in) 

(1.8” in) 

(3.4” in) 

(1

.1

”in

(1

.8

” 

in

Содержание 2MTHWT-HMD-II

Страница 1: ...DIGITAL DETECTION MODULE Quick Guide Version 1 01 REV06122020 ...

Страница 2: ...onnect to a face recognition access control terminal through the RS485 interface The module supports temperature measurement and personnel information binding It is capable of rapidly identifying personnel information taking the temperature and generating an alarm for people with abnormal temperature In addition it allows setting a temperature threshold so as to strictly control the access permiss...

Страница 3: ...ded environment the operational environment should be with less dust to avoid the pollution of blackbody target Pollution degree 2 If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired 2 Appearance and size The actual device appearance shall prevail The figure below shows the device size 3 Structure and cable ice The actual ...

Страница 4: ...2V 2A and the lower limit of the operating voltage is DC 9V 12V 25 Wire Diameter mm 0 8mm 20 AWG 1mm 18 AWG 1 25mm 16 AWG 1 63mm 14 AWG Transmission Distance m 18 37 58 99 2 Wiring description The figure below shows the wiring between the digital detection module and different devices For the wiring terminal of each device see the operation manual of the device or consult manufacturers Digital det...

Страница 5: ...nd a face recognition access control terminal face recognition terminal by referring to section Device Wiring and sections related to the wiring in the quick guide of the face recognition access control terminal face recognitionterminal 1 Wall mount The figure below shows the process of installing the digital detection module on a wall when the module is to be used in combination with a face recog...

Страница 6: ...ation mode requires the 2WTK SZWB bracket which needs to be purchased separately 2 Standing pole mount The figure below shows the process of installing the digital detection module on a standing pole when the module is to be used in combination with a face recognition access control terminal face recognition terminal 3 Fix the temperature measurement module ...

Страница 7: ...ice configuration Local configuration When the digital detection module is used in combination with a face recognition access control terminal you can enable the temperature measurement function on the Authentication Scene interface of the face recognition access control terminal Tap and hold the GUI for more than 3s Enter the correct activation password to go to the Activation Config interface Te...

Страница 8: ...n to the Web interface of the terminal and choose Setup Intelligent Advanced Setting to enable the temperature measurement function 3 Device operations When the temperature needs to be measured aim the wrist at the temperature measurement point at a distance of 0 39 1 inch Normal temperature Abnormal temperature ...

Страница 9: ... installed on a standing pole For details see Standing pole mount 2 This label is applicable when the temperature measurement module is mounted on the wall and the temperature measurement point is downward For details see installation mode 1 in Wall mount 3 This label is applicable when the temperature measurement module is mounted on the wall and the temperature measurement point is outward For d...

Страница 10: ...om an outdoor low temperature environment to the measurement area the person needs to stay in this area for 5min before the temperature is taken What should I do if the temperature measured by the device is inaccurate 1 The device requires preheating after power on It enters the optimal temperature measurement state 15minutes later 2 Check whether the wrist is aimed at thetemperature measurement p...

Страница 11: ...re for example getting out of a hotcar doing strenuous exercise or carrying hot drinks and hot food If yes the person needs to stay in the measurement area calmly and have the temperature taken 5 minutes later 2 Check whether the device is used in an overheated environment If yes deploy the device in an indoor windless environment with the temperature of 10 Cto 45 C 3 Use a medical grade temperatu...

Страница 12: ... different from the actual appearances functions features etc of the product This manual is intended for multiple software versions and the illustrations and descriptions in this manual may be different from the actual GUI and functions of thesoftware Despite our best efforts technical or typographical errors may exist in this manual Our company cannot be held responsible for any such errors and r...

Страница 13: ...ng personal injury exceed the amount of money that you have paid for the product Network Security Please take all necessary measures to enhance network security for your device The following are necessary measures for the network security of your device Change default password and set strong password You are strongly recommended to change the default password after your first login and set a stron...

Страница 14: ...ll applicable requirements are met to avoid danger and loss of property Storage Transportation and Use Store or use the device in a proper environment that meets environmental requirements including and not limited to temperature humidity dust corrosive gases electromagnetic radiation etc Make sure the device is securely installed or placed on a flat surface to prevent falling Unless otherwise spe...

Страница 15: ...de gaz inflammables Remplacer la batterie par un type incorrect Disposer d une batterie dans le feu ou un four chaud écraser mécaniquement ou couper la batterie Disposer la batterie utilisée conformément à vos règlements locaux ou aux instructions du fabricant de la batterie Regulatory Compliance FCC Statements This device complies with Part 15 of the FCC Rules Operation is subject to the followin...

Страница 16: ...ective 2012 19 EU The product this manual refers to is covered by the Waste Electrical Electronic Equipment WEEE Directive and must be disposed of in a responsible manner Battery Directive 2013 56 EC Battery in the product complies with the European Battery Directive 2013 56 EC For proper recycling return the battery to your supplier or to a designated collection point ...

Страница 17: ...802 Greenview Dr Grand Prairie TX 75050 USA Toll Free 1 866 708 5401 Fax 1 972 999 4113 sales 2MTechnology net ...

Отзывы: