83
Mask
Open
Door
If
Detection
Failed
The
options
are
On
and
Off
.
Set
the
parameter
based
on
the
actual
conditions.
The
default
value
is
Off
.
After
On
is
clicked,
when
the
face
recognition
terminal
detects
that
a
person
does
not
wear
a
mask,
a
prompt
is
displayed
on
the
GUI
and
a
voice
prompt
(please
wear
a
mask)
is
played
but
the
authentication
(face
scan,
IC
card,
ID
card)
and
door
opening
result
will
not
be
affected.
After
Off
is
clicked,
when
the
face
recognition
terminal
detects
that
a
person
does
not
wear
a
mask,
a
prompt
is
displayed
on
the
GUI
and
a
voice
prompt
(please
wear
a
mask)
is
played,
and
the
door
will
not
open.
Temperature
Measurement
Temperature
Measurement
Measure
Forehead
Temperature:
The
forehead
temperature
will
be
measured.
Measure
Wrist
Temperature:
The
wrist
temperature
will
be
measured.
Do
not
need
configuration.
Terminal
will
automatically
match
the
temperature
measurement
mode
when
it
is
connected
to
the
digital
detection
module.
Authentication
Failed
And
Open
The
Door
The
options
are
On
and
Off
.
Set
the
parameter
based
on
the
actual
conditions.
The
default
value
is
Off
.
After
On
is
clicked,
when
the
digital
detection
module
detects
that
a
person's
temperature
exceeds
the
preset
temperature
alarm
threshold,
a
prompt
is
displayed
on
the
GUI
and
a
voice
prompt
(abnormal
temperature)
is
played
but
the
authentication
(face
scan,
IC
card,
ID
card)
and
door
opening
result
will
not
be
affected.
After
Off
is
clicked,
when
the
digital
detection
module
detects
that
a
person's
temperature
exceeds
the
preset
temperature
alarm
threshold,
a
prompt
is
displayed
on
the
GUI
and
a
voice
prompt
(abnormal
temperature)
is
played
and
the
door
will
not
open.
Temperature
Measurement
Range
Value
range:
[30–45];
default
range:
[34–42]
Configure
the
range
based
on
actual
application
scenes.
Temperature
Alarm
Threshold
When
the
digital
detection
module
detects
a
temperature
higher
than
the
threshold
configured
here,
the
"abnormal
temperature"
alarm
is
displayed
on
the
GUI
and
the
warning
sound
is
played.
Value
range:
[30–45];
default
value:
37.3
Temperature
Alert
The
options
are
On
and
Off
.
Set
the
parameter
based
on
the
actual
conditions.
The
default
value
is
Off
.
After
turning
on
the
temperature
alert,
when
body
temperature
is
within
the
range
of
temperature
alert
threshold
and
temperature
alarm
threshold,
high
temperature
alarm
will
be
given
to
remind
people
to
re
‐
detect.
Temperature
Alert
Offset
Temperature
Alert
Threshold
=
Temperature
Alarm
Threshold
‐
Temperature
Alert
Offse
Alarm
Output
Configuration
High
Temperature
Alarm
The
options
are
On
and
Off
.
Set
the
parameter
based
on
the
actual
conditions.
The
default
value
is
Off
.
After
turning
on
the
high
temperature
alarm,
terminal
will
output
a
high
temperature
alarm
when
digital
detection
module
detects
high
temperature.
Not
Wearing
Mask
Alarm
The
options
are
On
and
Off
.
Set
the
parameter
based
on
the
actual
conditions.
The
default
value
is
Off
.
After
turning
on
the
not
wearing
mask
alarm,
terminal
will
output
a
not
wearing
mask
alarm
when
it
detects
people
who
not
wearing
a
mask.
Blacklist
Alarm
The
options
are
On
and
Off
.
Set
the
parameter
based
on
the
actual
conditions.
The
default
value
is
Off
.
After
turning
on
the
blacklist
alarm,
terminal
will
output
a
blacklist