-9-
7.
Setting Unlock Mode
For Outdoor Station
8.
Setting Unlock Time
For Outdoor Station
By default, the unlock time is 5 seconds, but it can be changed,the setting range is 1s~99s.
Follow the steps:
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer
Beep+, Beep
In standby mode, press
KEY_SET
button
three
times
.
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer
Beep,Beep......
Press and hold on
KEY_2
button. The time you holding
on is the new unlock time.
• When entering time delayed setting, the buzzer sound one time every second.
•
The
LED_NAME
indicator will blink all the time until exit out the setting mode.
• If without any operation in 10 seconds, it will exit out setting mode automatically.
• In this step,press
KEY_SET
button twice to exit out the setting mode manually.
There are 2 unlock modes,
Normally opened (Factory default)
and
Normally closed
.
Normally opened is default, to change the setting, please follow the steps:
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer
Beep+, Beep
In standby mode, press
KEY_SET
button
three
times
.
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer
Beep+
Press
KEY_1
button to set
the unlock mode to
Normally opened
.
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer
Beep, Beep
Press
KEY_1
button again
to set the unlock mode to
Normally closed
.
Press
KEY_1
• If setting mode has not been exited, you can change the unlock mode by pressing KEY1 circularly.
•
The
LED_NAME
indicator will blink all the time until exit out the setting mode.
• If without any operation in 10 seconds, it will exit out setting mode automatically.
• In this step,press
KEY_SET
button twice to exit out the setting mode manually.