With DT-CAM wiring mode
Electric Lock Connection
Door Lock Controlled with Internal Power
Door Lock Controlled with Dry Contact
EB
*
LOCK
Jumper position in
Connect one lock
2-3
Bus PL S2+ S1+ S1-
DIP Switch Setting
Bit state
Description
ON(1)
=
OFF(0)
=
ON
ON
1 2
3
ON
1 2
3
ON
1 2
3
ON
1 2
3
ON
ID = 0(00), set to the first door station
ID = 1(10), set to the second door station
ID = 2(01), set to the third door station
ID = 3(11), set to the fourth door station
LOCK
Take off the Jumper
POWER
SUPPLY
Bus PL S2+ S1+ S1-
1 2 3
AC~
PC6
ERL
DT595A
DT-CAM
DS
IM
Bus PL S2+ S1+ S1-
OUT IN
Monitor
Door station DIP setting
The DIP switch is designed to set the code the for door station and the monitor, there
are two states for each DIP switch, please refer to the following:
Total 3 bits can be configured, bit-1 and bit-2 are used to assign ID code for door
station, bit-3 is used to match the video impedance.The switches can be modified either
before or after installation.
Note:
for
video impedance
EOL:
set the bit-3 on.
Indoor monitor DIP setting
There are 6 bits in total. The DIP switches are used to configure the user address for Monitors.
Note:
1. The external power supply must be used
according to the lock.
2. The jumper must be taken off before connecting.
3. Setup the Unlock Mode of Monitor for different
lock types.
* Power-on-to-unlock type:Unlock Mode=0 (by default)
* Power-off-to-unlock type:Unlock Mode=1
-
7
-
Bit-6 is an video impedance EOL switch, set to ON to match the impedance.
Bit-1~Bit-5 are used to set user address, the user code should set be set to
0~15. Please refer to the following settings: