Door Lock Controlled with Dry Contact
EB
*
LOCK
Jumper position in
Connect one lock
2-3
Bus PL S2+ S1+ S1-
DIP Switch Setting
The DIP switch is designed to set the code for door station and monitor, there are two states for
each DIP switch, please refer to the following sketch map.
Door station DIP setting
Indoor monitor DIP setting
Bit state
Description
ON(1)
=
OFF(0)
=
ON
ON
Total 3 bits can be configured, bit-1 and bit-2 are used to assign ID code for door station, bit-3 is
used to match the video impedance.The switches can be modified either before or after installation.
There are 6 bits in total. The DIP switches are used to configure the user code for Monitors.
Bit-6 is an video impedance match switch, which have to be set to ON if match the impedance,
otherwise set to OFF.
Bit-1~Bit-5 are used to set user code, to DT595A door station, the user code should set to 0~15.
Please refer to the following settings:
Note: if the video impedance need to match, please set the bit-3 on.
1 2
3
ON
1 2
3
ON
1 2
3
ON
1 2
3
ON
ID = 0(00), set to the first door station
ID = 1(10), set to the second door station
ID = 2(01), set to the third door station
ID = 3(11), set to the fourth door station
LOCK
Take off the Jumper
POWER
SUPPLY
Bus PL S2+ S1+ S1-
1 2 3
AC~
PC6
ERL
DT595A
DT-CAM
DS
IM
Bus PL S2+ S1+ S1-
OUT IN
With DT-CAM wiring mode - NOT UK
The audio door station DT595A can be extended an additional CCTV camera to be a
video door station. For more details about the camera, please refer to DT-CAM user
instructions.
Note:
1. Electronic lock of Power-on-to-unlock (fail
secure) type should be used.
2. The door lock is limited to 12V, and holding
current must be less than 250mA.
3. The door lock control is not timed from Exit
Button(EB).
4. The Unlock Mode Parameter of Monitor must
be set to 0 (by default).
Note:
1. An external power supply must be used
depending on they type of lock used.
2. The jumper must be taken off before
connecting a lock
3. Set the Unlock Mode of the Monitor for
different lock types.
* Power-on-to-unlock type: Unlock Mode=0 (by
default) * Power-off-to-unlock type: Unlock
Mode=1
Audio
Handset
Electric Lock Connecton
Door Lock Controlled with Internal Power
-
5
-
Содержание 17-D
Страница 11: ......