Use the DIP switch and PROG button to change the unlock setting. 

 
 

1. Set DIP

1=ON, DIP

2=OFF; 

2. Press the PROG (Fig 1) button and hold for 3 secs (blue LED on) to activate the setup option: 

1) NO relay: press the PROG button one more time. 
2) NC relay: press the PROG button and hold for 3s again. 

 

 

1. Set DIP

1=OFF, DIP

2=ON; 

2.  Press the PROG (fig 1) button and hold for 3 secs (blue LED on) to activate the setup option: 
3.  Press  the  PROG (fig 1)  button  and  hold  for  the  number  of  seconds  req uired (indicted by beeps and 
red LED).  The  time between pressing and releasing the PRGO button is the unlock time. 

 

 

Note

:  DIP

1  and  DIP

2  should  reset  to  the  corresponding  ad dress code  after setting the above. 

 
 
 

   

Fig. 1 

 
 
 
 
 

1 2 3

Prog Button

CDV17DS PCB

 

Instructions for Lock Relay 1 Setting: 

UNLOCK TYPE 

UNLOCK TIME 

-

6

-

Содержание 17-D

Страница 1: ...2 Wire Intercom System Read this manual carefully before using the product and keep safe for future use CDV17DS INSTALLATION MANUAL EN ...

Страница 2: ... show visual verification of operation The rain cover provides protection adverse weather Connection Cable BUS Blue Green connect to the bus line no polarity S2 Red the S2 connect with S1 to activate the relay of ERL to extend a camera of DT CAM please refer to DT CAM user instructions in details Lock Control Jumper For selection of lock type Please refer to Electric Lock Connection Pg7 DIP switch...

Страница 3: ...on of outdoor station should kept away from direct snow rain and intense light Accessory contents Accessories include a screwdriver T20 one M4x10 screw two PA4x25 screws three PA3x25 screws three PM3x12 screws and five screw stoppers 6x30 Installation steps Installation height for door station usually is 145 160cm 1 Use screws to fix the back panel and rain cover to the wall connect the cable corr...

Страница 4: ...s PL S2 S1 S1 Bus PL S2 S1 S1 1 2 3 ON ID 00 Code 0 DIP 6 off 1 2 3 4 5 6 ON Code 1 DIP 6 off 1 2 3 4 5 6 ON AC PC6 AC PC6 Code 14 DIP 6 off 1 2 3 4 5 6 ON Code 15 DIP 6 on 1 2 3 4 5 6 ON Mult Door Staton Connecton BUS Blue Green S2 Red PL White S1 Yellow S1 Black Multi Monitors ConnectionBasic IN OUT wiring mode Audio Handset Audio Handset Audio Handset Audio Handset Audio Handset 3 ...

Страница 5: ...ode 14 DIP 6 on Code 12 DIP 6 on OFF ON OFF ON DBC 4S A B C D DBC 4S A B C D Impedance switch Impedance switch DIP on off off DIP on off off 1 2 3 ON ID 00 AC PC6 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON With DBC 4S Wiring Mode Audio Handset Audio Handset Audio Handset Audio Handset Audio Handset Audio Handset Audio Handset Audio Handset 4 ...

Страница 6: ... Note 1 Electronic lock of Power on to unlock fail secure type should be used 2 The door lock is limited to 12V and holding current must be less than 250mA 3 The door lock control is not timed from Exit Button EB 4 The Unlock Mode Parameter of Monitor must be set to 0 by default Note 1 An external power supply must be used depending on they type of lock used 2 The jumper must be taken off before c...

Страница 7: ... Set DIP 1 OFF DIP 2 ON 2 Press the PROG fig 1 button and hold for 3 secs blue LED on to activate the setup option 3 Press the PROG fig 1 button and hold for the number of seconds required indicted by beeps and red LED The time between pressing and releasing the PRGO button is the unlock time Note DIP 1 and DIP 2 should reset to the corresponding address code after setting the above Fig 1 1 2 3 Pr...

Страница 8: ...ch please refer to the following Total 3 bits can be configured bit 1 and bit 2 are used to assign ID code for door station bit 3 is used to match the video impedance The switches can be modified either before or after installation Note for video impedance EOL set the bit 3 on Indoor monitor DIP setting There are 6 bits in total The DIP switches are used to configure the user address for Monitors ...

Страница 9: ... Working status 200mA Lock Power Supply 12Vdc 300mA Internal Power Working Temperature 10ºC 45ºC Wiring 2 wires non polarity Dimension 137 H x49 W x28 D mm Please clean the unit with soft cotton cloth do not use a chemical cleaning agent If necessary please use a little pure water or dilute soap water to clean the dust The unit is weather resistant However do not spray high pressure water on acces...

Страница 10: ...0 30 20 70 50 30 Twisted cable 2x1 5 mm2 B A C DBC 4S AC PC6 Cable Requirements The maximum wiring distance is limited in the 2Easy system Using different cables can also affect the maximum distance achievable The furthest monitor with two to four monitors Note If the monitor has been specified the distance refer to the parameter Audio Handset Audio Handset Audio Handset 9 ...

Страница 11: ......

Страница 12: ...Right to interpret and copyright of this manual are preserved The design and specifications can be changed without notice to the user Right to interpret and copyright of this manual are preserved DT ENG 595A V1 P120924 ...

Отзывы: