REAR CONNECTIONS
POWER and BATTERY Loopback
(UPS operation)
The ZEUS TITAN has a built-in intelligent power circuit that can operate from +6.5v ~ +16V DC-IN.
A constant 12v Ignition and Ground are required. The DVR is energized by the vehicle’s ignition
signal and triggers start up, power shut-down delay and the timing circuitry. TITAN will remain
ON until the ignition signal has been turned off and the shut-down delay time has been reached.
The system will then go into Standby mode for the set period, then through its normal shutdown
procedures before completely powering down.
TITAN has an on-board battery system (“UPS” or uninterruptable power supply) for providing
backup power for up to 15 minutes after the main power has been lost. The UPS battery will
also keep the DVR running in case of voltage spikes (greater then 16VDC) and voltage drops
(less then 8VDC).
The Battery Loopback must be connected so the UPS battery can charge. Installers connect the
battery loopback to the DVR after the device has been fully installed and connected to the vehicle
power source.
Remove the loopback plug and store with the DVR when removing the DVR from the vehicle or
disconnecting the vehicle’s battery for extended periods of time.