background image

SBP-1100e User Manual  | 

3

the SCROLL button). The SBP-1100e may be used to provide power to a load while the battery pack is being charged. 

Charging stops automatically when it reaches the highest state of charge possible. There is no need to turn off or dis-

connect the charging power source when charging is complete, or be concerned about over-charging.

Battery Charging Using DC Power Sources

Generally, the SBP-1100e may be charged from filtered DC power sources ranging from 10 volts to 28 volts, provided 

the source can supply 200 watts. The power source need not be voltage-regulated (e.g. solar panels, 12V – 24V genera-

tors), but the voltage must not exceed 28 volts. However, only charging sources supplied or approved by 1100 Energy, 

should be used for charging the SBP-1100e. Please contact 1100 Energy for details. Unfiltered DC power sources, such 

as automotive battery chargers, should not be used for charging the SBP-1100e. Automotive power, by direct connec-

tion to the battery of a vehicle with the engine running, may generally be used to charge the SBP-1100e. At low voltages 

(10 – 12 volts) the SBP-1100e may draw 20 amps while charging, so avoid connecting the unit to an automotive DC 

power jack (cigarette lighter jack) if the jack is fused at less than 20 amps.

Battery Charging Using MF15-3600 Solar Panels

If the SBP-1100e is to be charged from MF15-3600 Solar Panels, connect a minimum of three solar panels, using a 

compatible solar adapter cable (see Accessories). Depending on the average power requirements of the load, and the 

amount of sunlight available, up to eight solar panels may be needed. The 2-pin connectors used to connect the solar 

panels to the cables should be tightly mated to keep out rain water, and all the connectors should be kept out of rain 

puddles if possible. Any unmated connectors should have the rubber safety caps which are tethered to them, installed 

securely onto the connectors, to protect from rain water. Avoid using the connectors near hazardous voltages.
When the cable and panel connections have been made, the charging status may be viewed on the status display on 

the SBP-1100e (push the SCROLL button). The SBP-1100e may be used to provide power to a load while the battery 

pack is being charged. Charging stops automatically when the SBP-1100e reaches the highest state of charge possible. 

There is no need to turn off or disconnect the charging power source when charging is complete, and there is no need 

to be concerned about over-charging.
Ideally, the solar panels should be oriented so sunlight strikes them approximately perpendicular to the panel surface 

during the mid-day hours, when the sun is strongest. For example, in the Northern hemisphere, at 40 degrees north 

latitude, for best performance the panels should face south, elevated about 40 degrees from the horizontal. In a loca-

tion near the equator, the panels should lie on a level surface. The panels should not be in shadow during the mid-day 

hours, to the extent possible.

Power Input Connection Specifications

Input Mating Plug:

 Model № 

SBP-CON-INPUT

 Input mating plug, miniature cylindrical, 5-pin female. MIL-C-26482 Series 

1, shell size 14 plug, 5 socket contacts, 16 AWG. MS3116F14-5S

Cable:

 16/4 type SOOW 4-conductor 16 AWG cable. Water and oil resistant rubber jacketed cable.

Connection Wiring Diagram

Pin

Description

Wire Color

A

+DC Input

Red

B

+DC Input

White

C

-DC Input (Return)

Black

D

-DC Input (Return)

Green

E

No Connection

No Connection

5-Pin Female Input Mating Plug (mating face view)

Содержание SBP-1100e

Страница 1: ...SBP 1100e Smart Battery Power System Software version 4 1 2 User Manual ...

Страница 2: ...r damage that result from a Improper operation or storage misuse or abuse accident or neglect such as physical damage to the surface of the product resulting from misuse b Subjecting the product to abnormal usage or conditions c Other acts which are not the fault of 1100 Energy are excluded from coverage Unauthorized Service or Modification Defects or damages resulting from service testing adjustm...

Страница 3: ...harging Using DC power sources 3 Battery Charging Using MF15 3600 Solar Panels 3 Power Input Connection Specifications 3 Supplying Power to a Load 4 Power Output On and Off Control 4 Power Output Connection Specifications 5 Serial Data Port 5 Serial Data Port Connection Specifications 5 Control Panel Buttons 6 LCD Backlighting 6 LCD Panel Indications 6 Storage 8 Outdoor Use 8 Lithium Ion 8 Caution...

Страница 4: ... SBP continues to power the application equipment during solar charging and afterwards using the stored energy In using input power available to the SBP 1100e priority is given to supplying power to the equipment load and any additional input power which may be available is used to charge the internal batteries until the batteries are fully charged So long as some stored energy in the SBP 1100e is...

Страница 5: ...y 10 hr discharge 72 Amp hours 13 8 volt model 40 Amp hours 25 3 volt model Temperature Range for charging 0 to 40 C 32 deg F to 104 deg F Temperature Range for discharging 20 to 50 C 4 deg F to 122 deg F Temperature Range for storage 20 to 60 C 4 deg F to 140 deg F Max Continuous Discharge Load less than 1 hour at 25 deg C 77 deg F 25 3 volts 300 watts 13 8 volts 280 watts 9 volts 180 watts 6 vol...

Страница 6: ...tate of charge from 40 to 49 The operational mode will appear on the bottom line of the LCD display unless the unit is charging in which case Charging will appear If the mode is Idle the unit is ready for use If the mode is Twilight connect a charging power source as described above and allow the unit to charge at least until the state of charge reaches about 15 To check whether the unit is ready ...

Страница 7: ...solar panels to the cables should be tightly mated to keep out rain water and all the connectors should be kept out of rain puddles if possible Any unmated connectors should have the rubber safety caps which are tethered to them installed securely onto the connectors to protect from rain water Avoid using the connectors near hazardous voltages When the cable and panel connections have been made th...

Страница 8: ...back to life within 3 seconds after external power is applied and after a suitable period of charging the SBP 1100e battery pack may again be used normally In the event that charging power is applied after the output has been cut off the state of charge must rise to about 15 before the output will be turned on again Power Output On and Off Control To check the output voltage and current press the ...

Страница 9: ...a Port Connection Specifications Note Fully assembled 10 foot SBP CBL RS232 10FT or 5 foot SBP CBL RS232 5FT RS 232 Data Cables are avail able from 1100 Energy The cables will connect the SBP 1100e directly to a 9 pin serial port of a personal computer Mating Plug Model SBP CON DATA Serial Data Port mating plug miniature cylindrical 5 pin female for SBP 1100e MIL C 26482 Series 1 shell size 10 plu...

Страница 10: ...CROLL button There is space for two lines of text or graphics on the display and when the SCROLL button is pressed the top line will display the present charge state in two formats the numerical percentage and a horizontal bar graph The per centage indicated is the relative state of charge between 0 fully discharged and 100 fully charged The bar graph indication uses darkened blocks to represent f...

Страница 11: ...rging and is not powering a load and thus is said to be idle Idle In the example below the unit is both charging or discharging that is some internal batteries are being charged while others are being discharged Dschrge Charge In the example below the input voltage and input current are displayed In 23 5V 3 2A In the example below the output voltage and output current are displayed Out 13 8V 4 3A ...

Страница 12: ...s battery capacity but prolonged storage at a moderate or low state of charge 40 or less or in a fully discharged state is not harmful All batteries including lithium ion batteries will slowly self discharge while in storage After several months in storage lithium ion batteries may go dead but the batteries can be readily brought back to life by applying a suitable wake up charging regimen The SBP...

Страница 13: ...toring purposes To see a list of accessories please visit our website at www 1100energy com or contact us Disposal At end of life please contact 1100 Energy for advice concerning disposal or recycling including options for returning the unit for refurbishing and renewal of the internal batteries Keep away from children Do not disassemble and do not dispose of in fire Contact information 1100 Energ...

Страница 14: ...10 Eleven Hundred Energy Corporation ...

Страница 15: ......

Страница 16: ...12 Eleven Hundred Energy Corporation ...

Страница 17: ... 2010 1100 Energy Corportion 2145 Priest Bridge Drive Crofton MD 21114 410 721 9032 sales 1100energy com www 1100energy com ...

Отзывы: