background image

4

  |  Eleven Hundred Energy Corporation

Supplying Power to a Load

To use the SBP-1100e to power a DC load, first determine whether the fixed voltage provided by the SBP-1100e (e.g. 

13.8 VDC or 25.3 VDC, etc) is appropriate for the load, and that the power demanded by the load will not exceed 300 

watts on a continuous basis. If continuous power in excess of 300 watts is required, consult 1100 Energy.
Connect the SBP-1100e power output jack on the right side of the unit to the load using the provided cable or other 

approved cable. A short output cable terminated with ring terminals, provided by 1100 Energy, may be used to con-

nect with another, longer, user-provided cable if appropriate. User-specified extension cables should be of a wire gauge 

adequate to avoid an excessive voltage drop in the extension cable.
The panel display may be controlled to show the voltage, current and an estimate of the remaining battery pack charge 

as a percentage of the charge capacity. The SBP-1100e may be used to provide power to a load while the battery pack 

is being charged.
If the SBP-1100e becomes fully discharged, and the output cuts off, a small amount of residual stored energy will 

maintain functionality of the user interface for one hour or more. This feature is partly for user convenience during at-

tended operation and testing, and it also keeps the serial control and monitor interface functioning. If no new charge is 

added after the output cuts off, the user interface will cut off as well, after 30 minutes, and the unit will then appear to 

be totally dead, with no power output, no display, and no response to button pressing. The SBP-1100e is in hibernation.

However, the user interface will come back to life within 3 seconds after external power is applied, and after a suitable 

period of charging, the SBP-1100e battery pack may again be used normally. In the event that charging power is applied 

after the output has been cut off, the state of charge must rise to about 15% before the output will be turned on again.

Power Output ‘On’ and ‘Off’ Control

To check the output voltage and current, press the ‘SCROLL’ button on the Control Panel repeatedly (slowly) until the 

second line of text of the LCD display shows the output voltage and current, for example:

Out 13.8V 00.0A 

This display will persist for eight seconds, during which time the ‘SELECT’ button may be pressed to toggle the power 

output ‘on’ and ‘off’. That is, if the power output is ‘on’, pressing “SCROLL’ once will turn it off, and if the power output is 

‘off’, pressing “SCROLL’ once will turn it on. The change in output voltage and current resulting from turning the output 

‘on’ or ‘off’ will not appear immediately on the LCD display, because the display is a frozen snapshot of the state exist-

ing when the ‘SCROLL’ button was pressed. To see the new output voltage and current, again press the ‘SCROLL’ button 

repeatedly (slowly) until the new data is displayed. Note that if there is no load connected to the SBP-1100e and the 

power output is turned off, it may take 30 seconds or more for the indicated output voltage to fall below one volt, due to 

stored charge in the output regulation circuit. If a load is present, the output voltage will instantly drop to zero when the 

output power is turned off.

The SBP-1100e has a very high power and energy density. Mishandling may present a risk of fire or explosion. Exer-

cise common sense precautions when handling, transporting, or testing. DO NOT OPEN the battery pack case and 

replace individual cells or modules. Usage should be carefully coordinated with 1100 Energy to ensure proper opera-

tion and safety.

Содержание SBP-1100e

Страница 1: ...SBP 1100e Smart Battery Power System Software version 4 1 2 User Manual ...

Страница 2: ...r damage that result from a Improper operation or storage misuse or abuse accident or neglect such as physical damage to the surface of the product resulting from misuse b Subjecting the product to abnormal usage or conditions c Other acts which are not the fault of 1100 Energy are excluded from coverage Unauthorized Service or Modification Defects or damages resulting from service testing adjustm...

Страница 3: ...harging Using DC power sources 3 Battery Charging Using MF15 3600 Solar Panels 3 Power Input Connection Specifications 3 Supplying Power to a Load 4 Power Output On and Off Control 4 Power Output Connection Specifications 5 Serial Data Port 5 Serial Data Port Connection Specifications 5 Control Panel Buttons 6 LCD Backlighting 6 LCD Panel Indications 6 Storage 8 Outdoor Use 8 Lithium Ion 8 Caution...

Страница 4: ... SBP continues to power the application equipment during solar charging and afterwards using the stored energy In using input power available to the SBP 1100e priority is given to supplying power to the equipment load and any additional input power which may be available is used to charge the internal batteries until the batteries are fully charged So long as some stored energy in the SBP 1100e is...

Страница 5: ...y 10 hr discharge 72 Amp hours 13 8 volt model 40 Amp hours 25 3 volt model Temperature Range for charging 0 to 40 C 32 deg F to 104 deg F Temperature Range for discharging 20 to 50 C 4 deg F to 122 deg F Temperature Range for storage 20 to 60 C 4 deg F to 140 deg F Max Continuous Discharge Load less than 1 hour at 25 deg C 77 deg F 25 3 volts 300 watts 13 8 volts 280 watts 9 volts 180 watts 6 vol...

Страница 6: ...tate of charge from 40 to 49 The operational mode will appear on the bottom line of the LCD display unless the unit is charging in which case Charging will appear If the mode is Idle the unit is ready for use If the mode is Twilight connect a charging power source as described above and allow the unit to charge at least until the state of charge reaches about 15 To check whether the unit is ready ...

Страница 7: ...solar panels to the cables should be tightly mated to keep out rain water and all the connectors should be kept out of rain puddles if possible Any unmated connectors should have the rubber safety caps which are tethered to them installed securely onto the connectors to protect from rain water Avoid using the connectors near hazardous voltages When the cable and panel connections have been made th...

Страница 8: ...back to life within 3 seconds after external power is applied and after a suitable period of charging the SBP 1100e battery pack may again be used normally In the event that charging power is applied after the output has been cut off the state of charge must rise to about 15 before the output will be turned on again Power Output On and Off Control To check the output voltage and current press the ...

Страница 9: ...a Port Connection Specifications Note Fully assembled 10 foot SBP CBL RS232 10FT or 5 foot SBP CBL RS232 5FT RS 232 Data Cables are avail able from 1100 Energy The cables will connect the SBP 1100e directly to a 9 pin serial port of a personal computer Mating Plug Model SBP CON DATA Serial Data Port mating plug miniature cylindrical 5 pin female for SBP 1100e MIL C 26482 Series 1 shell size 10 plu...

Страница 10: ...CROLL button There is space for two lines of text or graphics on the display and when the SCROLL button is pressed the top line will display the present charge state in two formats the numerical percentage and a horizontal bar graph The per centage indicated is the relative state of charge between 0 fully discharged and 100 fully charged The bar graph indication uses darkened blocks to represent f...

Страница 11: ...rging and is not powering a load and thus is said to be idle Idle In the example below the unit is both charging or discharging that is some internal batteries are being charged while others are being discharged Dschrge Charge In the example below the input voltage and input current are displayed In 23 5V 3 2A In the example below the output voltage and output current are displayed Out 13 8V 4 3A ...

Страница 12: ...s battery capacity but prolonged storage at a moderate or low state of charge 40 or less or in a fully discharged state is not harmful All batteries including lithium ion batteries will slowly self discharge while in storage After several months in storage lithium ion batteries may go dead but the batteries can be readily brought back to life by applying a suitable wake up charging regimen The SBP...

Страница 13: ...toring purposes To see a list of accessories please visit our website at www 1100energy com or contact us Disposal At end of life please contact 1100 Energy for advice concerning disposal or recycling including options for returning the unit for refurbishing and renewal of the internal batteries Keep away from children Do not disassemble and do not dispose of in fire Contact information 1100 Energ...

Страница 14: ...10 Eleven Hundred Energy Corporation ...

Страница 15: ......

Страница 16: ...12 Eleven Hundred Energy Corporation ...

Страница 17: ... 2010 1100 Energy Corportion 2145 Priest Bridge Drive Crofton MD 21114 410 721 9032 sales 1100energy com www 1100energy com ...