background image

  PBP - 03 BISTABLE RELAY 

INSTRUCTION MANUAL

Zakład Mechaniki i Elektroniki 

ZAMEL sp.j.

J.W. Dzida, K. Łodzińska

ul. Zielona 27, 43-200 Pszczyna, Poland

Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04

www.zamelcet.com, e-mail: [email protected]

APPERANCE

FEATURES

DESCRIPTION

ی  Bistable lighting control,

ی  Time limit function,

ی  Soft start and switch-off (0.8 s),

ی  Load ON indicator – red LED,

ی  Device triggering by means of the L 

wire,

ی  Applicable together with the single 

pole push buttons, illuminated,

ی  Two-conductor control system,

ی  Easy applicable together with any 

existing electrical system,

ی  Supplied in series with load.

The  PBP-03  bistable  relay  is  designed 
for lighting or any other unit by means of 
single  pole    push  buttons  connected  in 
parallel. Successive pressing of any but

-

ton causes switching ON / OFF the load 
connected to the output terminals alterna

-

tively.  The L line is a source of a control 
impulse.  After  the  impulse  has  arrived 
t delay time will be measured and then,   
the  load  will  be  OFF.    It  is  possible  to 
mount the device under a push button, in 
a deep junction box of 60 mm diameter.

TECHNICAL DATA

PBP - 03 

Power terminals:  L (black),   brown – in series with the load

Rated voltage: 230 V

Rated voltage tolerance: -15 ÷ +10 %

Rated frequency: 50 Hz

Rated current:  8 mA

Load supply indicator: red LED

Trigger conductor: IN (red)

Load supply:

 brown

ON-time adjustment range: 10 s ÷ 16 min
ON-time setting accuracy: ±3 %

ON-time setting repeatability: ±5 %

ON-time setting: continuous (rotary potentiometer)

Permissible load: 30 ÷ 300 W

Fuse technical specification: 5 x 20 mm, ultra-fast, 2 A / 250 V

Control: triac

Connection wires quantity:

3

Connection wire section: 1 mm

2

Operating temperature: -20 ÷ +45 

o

C

Operating position: optional

Casing fastening: for 60 mm junction box

Casing IP: IP40

Protection class:

II

Overvoltage category:

II

Pollution level: 2

Dimensions: 50 x 50 x 15 mm

Weight: 28 g

Standard conformity: PN-EN 60669-1, PN-EN 60669-2-1,

PN-EN 61000-4-2,3,4,5,6,11

Load ON indicator

Load power lead 

Power lead (L)

Fuse socket

Trigger conductor (IN)

ON-time adjustment

b

ro

w

n

r

ed

b

l

a

c

k

The  timer  should  be 
connected  to  a  single-
phase  system  accordin

-

gly to current standards.
The  device  connections 
will be described  in this 

manual.  Only  qualified  electricians  are 
allowed  to assembly, connect and ad

-

just the timer. It is necessary to read this 
manual  before  the  timer  mounting.  Do 
not disassembly the timer casing or you 
will lose any warranty rights and expo

-

se yourself to the electric shock hazard. 
Before  mounting  operation  make  sure 
of  disconnecting  the  connection  wires  
from  the  electric  network.    The  timer 
should  be  carried,  stored  and  used  in 
an appropriate way.  Do not mount the 
timer  in  case  of  any  device  parts  lack, 
damage or deformation. In case of mal

-

function please notify the manufacturer.

CAUTION

Reviews: