background image

 
 

 

 

 

 

 

 

Digital Portion Scale 

AW-300P 

USER MANUAL 

 

PLEASE TAKE THE TIME TO READ THESE INSTRUCTIONS BEFORE 

STARTING TO USE THE SCALES

 

 
 

 

TABLE OF CONTENTS 

 

TABLE OF CONTENTS ................................................................... 1 

INTRODUCTION.............................................................................. 2 

SAFETY INSTRUCTION .................................................................. 2 

CLEANING....................................................................................... 3 

MAINTENANCE ............................................................................... 3 

DISPOSING OF THE SCALE........................................................... 3 

Explanation of the graphic symbols.................................................. 4 

TO Ready Scale for Use .................................................................. 5 

POWER SUPPLY & LOW BATTERY ............................................... 5 

SPECIFICATIONS............................................................................ 6 

KET FUNCTIONS ............................................................................ 7 

USING SCALE ................................................................................. 8 

USING TARE FUNCTION ................................................................ 8 

USING HOLD FUNCTION ............................................................... 9 

AW-300P : SET-UP ........................................................................ 11 

INSTRUCTION FOR CHARGE AND CONNECT ........................... 12 

Parameters of RS232 interface ...................................................... 14 

ERROR MESSAGE........................................................................ 18 

ROHS COMPLIANCE .................................................................... 19 

Summary of Contents for AW-300P

Page 1: ...N 2 SAFETY INSTRUCTION 2 CLEANING 3 MAINTENANCE 3 DISPOSING OF THE SCALE 3 Explanation of the graphic symbols 4 TO Ready Scale for Use 5 POWER SUPPLY LOW BATTERY 5 SPECIFICATIONS 6 KET FUNCTIONS 7 USING SCALE 8 USING TARE FUNCTION 8 USING HOLD FUNCTION 9 AW 300P SET UP 11 INSTRUCTION FOR CHARGE AND CONNECT 12 Parameters of RS232 interface 14 ERROR MESSAGE 18 ROHS COMPLIANCE 19 ...

Page 2: ...plicable standards These batteries should be kept away from small children If swallowed promptly seek medical assistance Expected Service Life 5 years If you have any problem contact your local service partner 3 CLEANING We would recommend using alcohol based wipes or similar when cleaning the scales Please do not use large amounts of water when cleaning the scales as this will cause damage to the...

Page 3: ...e setup and commissioning even if you are already familiar with Yamato scales 5 TO Ready Scale for Use 1 Remove the scale from its box along with any protective film from the platform cover 2 Place the scale on a hard flat surface Uneven surfaces will affect accuracy If using the adapter make sure the scale is not resting on the cord otherwise it may be unstable POWER SUPPLY LOW BATTERY 1 The AW W...

Page 4: ... Power Supply 6 AA size batteries 15V DC adapter 100 300mA Operation Temperature 5 35 PANEL 7 KET FUNCTIONS Key Description Turn ON OFF the scale To hold weighing result on the display determine stable weighing value To select the weighing unit kg lb Tare weight during weighing process The Hold weighing function is active Stored Tare value Stable symbol Minor weight value Indicates scale is at cen...

Page 5: ...is provided with the integrated hold function determination of average value It enables animal to be weighed accurately although they are not still on the scale plate Once the HOLD key is pressed the weight reading will remain on the display even after the animal has been moved from the scale platform so the reading can easily be read Note Determination of average value is not possible if the anim...

Page 6: ...isplay successively AUTO OFF TIME SETUP This enables operator to select the auto turn OFF time of the device BUZZER ON OFF SETUP This enables operator to select beep sound ON OFF Auto off time 120 sec 180 sec 240 sec 300 sec off Buzzer On Off Note To confirm the settings please press HOLD when displays on the display ...

Page 7: ...the adaptor from main power supply before taking out the AC adaptor pin from indicator INSTRUCTION FOR CHARGE AND CONNECT If prompt displays on the LCD please charge the scale with AW 300P exclusive adaptor or replace the batteries Locate adaptor plug in at the back side of indicator 13 INSTRUCTIONS FOR REPLACING BATTERIES ...

Page 8: ... program from clicking Start Menu Programs Accessories Communication Hyper Terminal 2 New Connection Description Give new connection a name then click OK 3 Select Your COM Port Click Connect to select your COM port Usually there s only one option for select Then click OK 4 Port Settings Click Bits per second to set up rate at 9600 Data bits at 8 Parity at None Stop bits at 1 and Flow control at Ha...

Page 9: ...16 17 ...

Page 10: ... at higher temperatures required by lead free soldering The restricted substances and maximum allowed concentrations in the homogenous material are by weight Substance Concentration Lead 0 1 Mercury 0 1 PBB Polybrominated Biphenyls 0 1 PBDE Polybrominated Diphenyl Ethers 0 1 Hexavalant Chromium 0 1 Cadmium 0 01 YAMATO CORPORATION 1775 S Murray Bivd Colorado Springs Co 80916 USA Tel 719 591 1500 Fa...

Reviews: