background image

 

 

 

 

 

 

 

 

 

 

 

 

TR-I 

series 

Wireless  Crane  Scale 

User’s guide

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UGTR-E1.02

 

 

Summary of Contents for TR-I Series

Page 1: ...TR I series Wireless Crane Scale User s guide UGTR E1 02 ...

Page 2: ...ALLATION 3 SECTION 4 KEY DESCRIPTIONS 5 SECTION 5 DISPLAYS 6 SECTION 6 OPERATION 7 6 1 Zeroing the display 7 6 2 Taring 7 6 3 Weighing a sample 7 6 4 Accumulated total 7 SECTION 7 PARAMETERS 8 SECTION 8 BATTERY OPERATION 10 SECTION 9 RS 232 OUTPUT 12 SECTION 10 CALIBRATION 13 SECTION 11 ERROR CODE 14 SECTION 12 TECHNICAL PARAMETES 15 ...

Page 3: ...re sealed color coded membrane switches and the displays are large easy to read liquid crystal type displays LCD The LCD s are supplied with a backlight All units include automatic zero tracking units conversion audible alarm for pre set weights and an accumulation facility that allows the individual weights to be stored and recalled as an accumulated total The crane scale is firm and durable and ...

Page 4: ...ure 0 C 40 C 32 F 104 F Power supply external 115 230 Vac 120 240 Vac 50 60Hz 10 watts Calibration Automatic External Display 6 digits 22mm LCD display attached backlight Housing Indicator ABS Plastic Crane scale Stainless Steel Zero range 0mV 5mV Signal input range 0 15mV ADC Sigma delta Internal counts 600 000 ADC update Max 60 times second Load cell drive voltage Max 5V 150mA Load cells Up to f...

Page 5: ...d high humidity that might cause condensation Avoid direct contact with water Do not spray or immerse the scales in water Avoid air movement such as from fans or opening doors Do not place near open windows Keep the indicator clean Do not stack material on the scales when they are not in use INSTALLATION OF TR SERIES Please make the load cell connector from the load cell follow the drawing below A...

Page 6: ...condary function of incrementing the active digit when setting a value for parameters or other functions HOLD reading lock key use this key to lock reading in calibrate mode use this key to change decimal point Secondary function In the setting mode this key used to move active digits right M To print the results to a PC or printer using the optional RS 232 interface It also adds the value to the ...

Page 7: ...e user s manual 5 SECTION 5 DISPLAYS The LCD display will show a value and a unit to the right of the digits In addition there are labels for TARE GROSS weight Zero and for Low battery Battery low Stable Check weighing Weighing unit ...

Page 8: ...when the platform is empty 6 2 Taring Zero the scale by pressing the ZERO key if necessary The zero indicator will be on Place a container on the platform a value for its weight will be displayed Press the ZERO key to tare the scale only when the weight is large than 10 capacity The weight that was displayed is stored as the tare value and that value is subtracted from the display leaving zero on ...

Page 9: ...umulate operate The weight displayed will be stored in memory when the M key is pressed and the weight is stable The display will show ACC 1 and then the total in memory for 2 seconds before returning to normal after do accumulate operate M indicator will turn on If the optional RS 232 interface is installed the weight will be output to a printer or PC Remove the weight allowing the scale to retur...

Page 10: ...er unchanged For example when the display shows F0 DIV then press the DIV key to select F1 az0 press the ZERO key to begin The display will show az 0 5d press the ZERO key to ensure or press the DIV to the next parameter When you select a suitable value press the ZERO key to ensure After pressing the ZERO key to set a value use the DIV key to continue to the next parameter and set it as needed Whe...

Page 11: ...o turn off time oFF 0 min turn on all the times oFF 5 min turn off auto after 5 minutes oFF 10 min turn off auto after 10 minutes oFF 15 min turn off auto after 15 minutes oFF 30 min turn off auto after 30 minutes OFF 0 F7 Prt Select print out format Cont continue send mostly use in computer communition LP 50 use LP 50 printer AUTO Prt 1 print out format 1 Prt 2 print out format 2 Prt 3 print out ...

Page 12: ...e the battery simply plug into the mains power The scale does not need to be turned on The battery should be charged for 12 hours for full capacity In the LCD display has a battery indicator to indicate the status of battery charging When the scale is plugged into the mains power the internal battery will be charged When turn on the indicator if the battery indicator is full then the battery has a...

Page 13: ...data ASCII code 8 data bits No Parity Baud rate 1200bps 9 2 print out format Format 1 NO 3 G W 20 50kg N W 18 30kg Format 2 NO 3 N W 18 30kg Format 3 NO 3 G W 20 50kg N W 18 30kg Format 4 NO 3 N W 18 30kg Format 5 NO 3 N W 18 30kg TOTAL 60 40kg 9 3 continuously output protocol con1 weighing mode k g CR LF HEADER1 HEADER2 WEIGHT DATA HEADER1 ST STABLE US UNSTABLE HEADER2 NT NET GS GROSS WEIGHT UNIT...

Page 14: ...DIV key until display shows F8 CaL 6 Press ZERO key to enter calibrate display shows ULOAD 7 Empty the hook after STABLE indicator on press ZERO key to sure after some seconds zero calibrate completely 8 After zero calibrate display shows span calibrate mass weight you can change this weight use HOLD key to move the active digit use DIV key to increment a digit after input calibrate mass weight pr...

Page 15: ...ard Error Keyboard short please check the key wire or whether the key have mechanical problem Err 6 A D out of range The values from the A D converter are outside the normal range Remove weight from the scale if overloaded make sure the pan is attached Indicates the load cell or the electronics may be faulty If the problem persist contact your dealer or Taiwan scale for assistance Err10 No single ...

Page 16: ... and their distributors offer a full range of technical services such as on site and workshop repair preventative maintenance and calibration facilities TAIWAN SCALE operates an approved quality management system and is certified to ISO9001 2000 Visit our Website at www taiwanscale com Taiwan Scale Mfg Co Ltd 282 Sec 3 Hoping W Rd Taipei Taiwan TEL 886 2 23068203 FAX 886 2 23044354 e mail adm tsc ...