background image

 

User Manual 

 

of Postal scales 

 
 

Manual number: 
ITKU-20-02-01-12-A 

 
 
 

 

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 
 
 

M A N U F A C T U R E R   O F   E L E C T R O N I C    
W E I G H I N G   I N S T R U M E N T S  

 

RADWAG Wagi Elektroniczne 26 – 600 Radom Bracka 28 Street - POLAND 
Phone +48 48 38 48 800, phone/fax. +48 48 385 00 10 
Selling depa48 48 366 80 06 

www.radwag.com 

Summary of Contents for ITKU-20-02-01-12-A

Page 1: ...01 12 A M AN U F AC T U R E R O F E L E C T R O N I C W E I G H I N G I N S T R U M E N T S RADWAG Wagi Elektroniczne 26 600 Radom Bracka 28 Street POLAND Phone 48 48 38 48 800 phone fax 48 48 385 00...

Page 2: ...2 JANUARY 2012...

Page 3: ...11 WEIGHING 16 11 1 Tarring 17 11 2 Inscribing tare value 17 11 3 Zeroing 18 11 4 Weighings in two ranges 18 11 5 Selection of basic weight unit 19 11 6 Temporarily selected unit 20 12 MAIN PARAMETER...

Page 4: ...Send the result immediately in basic unit 41 18 4 6 Send the stable result in current unit 41 18 4 7 Send the result immediately in current unit 42 18 4 8 Switch on continuous transmission in basic u...

Page 5: ...unction operating automatic tare memory of tare inscribing tare value automatic scale switch off user calibration 2 PRECAUTIONS 2 1 Maintenance A Please read carefully this user manual before and use...

Page 6: ...e symbols on accumulators identify harmful elements compounds Pb lead Cd cadmium Hg mercury 2 2 1 Power supply of weighing indicators in plastic casings Indicators in plastic casing are intended to be...

Page 7: ...to new ones in weighing indicators PUE C 31 plastic casing Procedure Open the lid of the chamber for batteries placed in the bottom of the indicator casing Remove discharged and then insert new batter...

Page 8: ...ng methods of elimination can be settled only in participation of a user and the manufacturer representatives C RADWAG does not take any responsibility connected with destructions or losses derives fr...

Page 9: ...9 G Contact with the central authorized service 48 48 384 88 00 ext 106 or 107 4 MAIN DIMENSIONS Scales of WPT P 2 series Scales of WPT P 60 series...

Page 10: ...P 2 series Unpack and put the scale on a flat even stable surface far away from sources of heat and then Remove transport protection Set the pillar with additional display vertically Screw down the p...

Page 11: ...n a flat even stable surface far away from sources of heat and then A Remove transport protection B To attach the pillar to the scale body Screw down the pillar handler to the platform Stretch delicat...

Page 12: ...on the pillar and tighten up the handwheels 6 GETTING STARTED After unpacking and mounting the scale level it out Use levelling legs and the level condition indicator installed in the basis of the sca...

Page 13: ...If the indication is not zero press key 7 KEYPAD 8 KEYS FUNCTIONS Switching on off Function key operation mode selection Sending a weighing result to RS232 Zeroing Tarring Notice After pressing keys f...

Page 14: ...ode weighing 8 Rechargeable battery pack or battery discharged BAT LO 9 Net Tare function has been used 10 USER MENU 10 1 Submenus User s menu is divided into 5 basic submenus Each group has its own c...

Page 15: ...eter or changing the value of a selected parameter Entering the selected submenu or activating a parameter for changes Confirmation enter Leaving without changes or reaching a higher level of the menu...

Page 16: ...ts of weighted loads following precautions should be taken into consideration Loads should be placed on the pan delicately and carefully in order to avoid mechanical shocks Loads should be placed cent...

Page 17: ...ll be shown Tarring is possible within the whole range of the scale After unloading the pan the display shows the tarred value with minus sign Notice Tarring cannot be performer when a negative or zer...

Page 18: ...possible within the scope of 2 of full scale While zeroing outside the scope of 2 you will see Err2 Zeroing is possible only in stable state Notice Zeroing is possible only within the 2 interval of th...

Page 19: ...Procedure Enter the submenu P3 Unit and then press until the expected unit appears on the display Options A When the basic unit is kg users can toggle between kg lb N for verified scales lb is not acc...

Page 20: ...2 Notice After turning on the scale always sets the basic unit 11 6 Temporarily selected unit This function is used to set weight unit the scale will use temporarily until the next power off or next...

Page 21: ...lb lb is not accessible for verified scales 12 MAIN PARAMETERS Users can adjust the scale to external ambient conditions filtering level or particular needs autozero operation tare memory This parame...

Page 22: ...el is the longer stabilization time is needed Return to weighing See 10 2 2 12 2 Median filter This filter eliminates short changes impulses of measure signal e g shocks Procedure Enter the submenu P1...

Page 23: ...declared value of autozero range so the scale will be automatically zeroed and the pictograms and will be displayed When AUTOZERO is disabled zero is not corrected automatically However in particular...

Page 24: ...on on and is stored in balance memory after unplugging it from mains tArA no automatic tare function off tArA tArF tare memory function stores last value of tare in balance memory It is automatically...

Page 25: ...It prevents from appearing a potential difference between zero leads of the two devices This notice does not apply to the devices that do not use zero leads Transmission parameters Baud rate 2400 3840...

Page 26: ...ation gross is lower than the value inscribed in S_Lo parameter Procedure Enter the submenu P2 Prnt and then Return to weighing see 10 2 2 14 OTHER PARAMETERS The user can set parameters which influen...

Page 27: ...ht for supplying from mains Procedure Enter the submenu P5 othr and then bL no backlight switched off bL YES backlight switched on bL Auto backlight switched off automatically if indication becomes st...

Page 28: ...rates without recharging or exchanging batteries When the intensity is set this function works as AUTO described above Procedure Enter the submenu P5 othr and then Return to weighing See 10 2 2 Notice...

Page 29: ...ghing appears in 5 minutes no changes on the display In case when this function disrupts the operation e g long time weighing procedures or while working with connection to mains switch off this funct...

Page 30: ...supplying from batteries too low level of voltage is measured by software the pictogram is displayed It means that charging or exchanging batteries is required 14 4 1 Checking the batteries This funct...

Page 31: ...y After one time the device will automatically switch off to protect the batteries from distructable discharging Charging is signalled by blinking period about 2 seconds on the display 14 4 3 Accumula...

Page 32: ...able batteries NiMH R6 AA and power adapter Procedure Enter the submenu P5 othr and then CHr6 YES enabled CHr6 no disabled Return to weighing See 10 2 2 14 4 4 Formatting rechargeable battery packs Po...

Page 33: ...self powering down 5 Repeat the process of charging starting from point 1 Notice They reach their optima capacity after three cycles of full charging and discharging 15 USER CALIBRATION Only for non...

Page 34: ...isplayed mass value on the pan and press The calibration process will start which is signalled by the message After completion of the process of calibration the following screen will appear Take off t...

Page 35: ...al will be emitted Press to perform calibration again with more stable ambient conditions 15 2 Start mass adjustment If the scale does not require the full calibration process sit is possible to adjus...

Page 36: ...key is pressed a current mass value together with mass units is sent to RS 232 interface One of thermal printer in KAFKA series can cooperate with each platform scales a KAFKA Only result of weighing...

Page 37: ...on the request from the computer After sending a control command These scales can cooperate with EDYTOR WAG program The indicator window comprises the most important information from the scale display...

Page 38: ...results Display control 18 2 A set of commands for RS interfaces Commands Description of commands Z Zeroing T Tarring TO Get tare S Send the stable result in basic unit SI Send the result immediately...

Page 39: ...nded XX _ E CR LF error while executing command time limit for stable result exceeded limit time is a descriptive parameter of the scale XX command name _ substitutes spaces 18 4 Command s description...

Page 40: ...R LF Possible answers TO_TARA CR LF command executed Frame format 1 2 3 4 5 6 7 15 16 17 18 19 20 21 T O space stability space tare space unit CR LF Tare 9 characters with decimal point justified to t...

Page 41: ...immediately in basic unit Syntax SI CR LF Possible answers SI_I CR LF command comprehended but cannot be executed at the moment MASS FRAME mass value in basic unit is returned Frame format 1 2 3 4 5...

Page 42: ...computer command S U _ A CR LF command accepted and in progress S U _ _ _ _ _ 1 7 2 1 3 5 _ N _ _ CR LF command done mass value in current unit is returned 18 4 7 Send the result immediately in curre...

Page 43: ...CR LF 18 4 9 Switch off continuous transmission in basic unit Syntax C0 CR LF Possible answers C0_I CR LF command comprehended but cannot be executed C0_A CR LF command comprehended and executed 18 4...

Page 44: ...le answers PC_ _Z T TO S SI SU SUI C1 C0 CU1 CU0 PC command executed the indicator have sent all the implemented commands 18 5 Manual printouts Users can general manual or automatic printouts from the...

Page 45: ..._ _ _ _ _ 2 2 3 7 _ l b _ CR LF the printout generated from the scale after pressing ENTER PRINT Example 3 _ _ _ _ _ _ 0 0 0 0 _ k g _ CR LF the printout generated from the scale after pressing ENTER...

Page 46: ...null that appear on the display are also signalled by a short beep sound about 1 sec 2 Error FULL2 that appears on the display is also signalled by a continuous sound until the cause of error disappe...

Page 47: ...ay Loaded weight pan during powering up Unload the pan Then the scale will indicator zero 22 ADDITIONAL EQUIPMENT Accessories KAFKA printer cable P0136 Computer cable P0108 EPSON printer cable P0151 P...

Page 48: ...F E L E C T R O N I C W E I G H I N G I N S T R U M E N T S RADWAG WAGI ELEKTRONICZNE 26 600 Radom Bracka 28 Street POLAND Tel 48 48 38 48 800 tel fax 48 48 385 00 10 Selling departament 48 48 366 80...

Reviews: