Step 1: Remove all 9 screws circled
above.  Then remove the top & rear
panel.

Step 2: Remove the two screws

indicated above and remove the

front panel. 

Step 3: Peel back insulation to
expose the 'ice making' sensor and
the 'ice full' sensor receive.

Step 4: Remove

everything from the upper front half

of the holding tank.

Step 5: Remove
the two screws located on the
holding tank, just behind the panel.

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

-

Phillips head screw driver
TDS meter
Microfiber towels & paper towels
Gloves
5 gallon bucket
Thermometer 
Tubing & tube cutters
Pledge multi-surface
Hydrogen Peroxide

You will need:

WS 12000 Annual PM Guide

The WS 12000 Unit needs preventative maintenance every year.  

Follow the instructions below for appropriate instructions.

Step 6: Carefully

remove the Styrofoam bin lid.

Part 1: Sanitizing the Unit

Pre-Sediment Filter (ICESEO): 1 year or 2500 gallons max
Pre-Carbon Filter (ICEPREC): 1 year or 2500 gallons max
Reverse Osmosis (ICERO): 3 years or 4500 gallons max
TCR Filter (ICEPOSTCA): 3 years or 2500 gallons max

Filter Change Regime:

What to do:

Summary of Contents for WS 12000

Page 1: ...river TDS meter Microfiber towels paper towels Gloves 5 gallon bucket Thermometer Tubing tube cutters Pledge multi surface Hydrogen Peroxide You will need WS 12000 Annual PM Guide The WS 12000 Unit needs preventative maintenance every year Follow the instructions below for appropriate instructions Step 6 Carefully remove the Styrofoam bin lid Part 1 Sanitizing the Unit Pre Sediment Filter ICESEO 1...

Page 2: ...under the ice tray and a stubby nose screw driver is needed Step 14 Remove plastic plugs and pull the ice bin liner out of the unit Step 15 If you have not already mix a solution of 1 part hydrogen peroxide to 5 parts water and put it in a spray bottle Spray all ice making storage surfaces liberally and wipe clean with a soft rag Never use anything abrasive on any of the ice making or storage surf...

Page 3: ...lect option 3 Step 16 Liberally spray the solution on the parts you removed and rinse in a sink Step 17 Slide clips into open position and remove the four screws in the top corners of the ambient tank to gain access inside Step 18 Liberally spray the inside of the ambient tank and rinse in a sink ...

Page 4: ... the post carbon filter Step 5 When the carbon filters are done flushing they can be relocated to their appropriate locations and the original tube put back into the manifold NOTE make sure the unit is making water before the unit is put back together The leak detector is a common reason for the unit not to fill after a PM For additional tips tricks and assistance contact Wellsys Tech support dire...

Reviews: