background image

USER’S MANUAL

KEEP THIS MANUAL FOR FUTURE REFERENCE

 

400 Watt

Power Dome

Compact Generator

Portable Power Source

Summary of Contents for Power Dome

Page 1: ...USER S MANUAL KEEP THIS MANUAL FOR FUTURE REFERENCE 400 Watt Power DomeCompact Generator Portable Power Source ...

Page 2: ...Volt Accessory Outlets for powering DC appliance loads to 18 Amps 6 1 USB power port 7 Bright Area light LED type for long battery life 8 AC Recharging Adapter 9 DC Recharging Adapter fused 10 Easy Read analog voltmeter for checking Battery Status 11 Jumpstart cable polarity indicator for safety FRONT VIEW Figure 1 shows the locations of the Compressor DC Power Outlets Battery Status Charging and ...

Page 3: ...sing the DC method 7 After charging the battery disconnect the adapter from the accessory socket first then from the charging jack 8 Replace the dust cover on the charging jack DC POWER PORT DC POWER PORTS accessory sockets are located under the Pressure Gauge and the Battery Status Meter voltmeter The ports can power a DC load of up to 11 Amps Overloading the port will result in tripping a self r...

Page 4: ...d close the dust cover 9 Recharge Power Dome as soon as convenient NOTES If the Power indicator LED is not lit then reduce the AC load If the inverter is still not operating refer to the troubleshooting table at the end of this User s Manual CAUTION Some rechargeable devices are equipped with a separate AC charger These devices will likely operate properly with this inverter Rechargeable devices t...

Page 5: ... vehicle 7 Observe the color of the REVERSE POLARITYLED that is located between the Battery Status and Work Light Switches 8 If the LED is RED DO NOT TURN ON THE CABLE JUMPER SWITCH Cable Clamps need to be reversed Disconnect the Black Clamp first and then the RED Cable Clamp Reconnect and observe the LED If the LED is green turn ON the Jumper Safety Switch 9 Inside the vehicle turn on the ignitio...

Page 6: ...nd inverter 2 Disconnect device 3 Turn the inverter ON and leave running for a minimum of 2 minutes 4 Turn OFF inverter quickly plug in device to inverter making sure device is OFF prior to connection 5 Turn ON the inverter and the device Inverter fuse blown Check and replace if necessary Be sure any replacement fuse is the same type and rating Inverter Power Indicator Excessive voltage drop Check...

Page 7: ...poration will at its option replaces or repair the defective part This warranty is void if the product has been damaged by accident in shipment unreasonable use misuse neglect improper service commercial use repairs by unauthorized personnel or other causes not arising out of defects in materials or workmanship This warranty is effective only if the product is purchased and operated in the USA and...