The OMV-VX outdoor visual verification detector is a wireless, 
battery operated, motion activated outdoor camera designed for 
use in Videofied

® 

security systems.

•  Powered by 3 Lithium batteries for extended battery life.  

•  4 infrared LEDs for 12m night vision.

•  Fully weatherproof (IP55) and temperature resistant 

(-20°C/+60°C).

•  12 m (40 ft.) by 90 degree flexible detection pattern adjustable 

to 5 ranges

•  SMDA Logic for advanced temperature compensation and 

environmental noise immunity.

•  Easy masking of sensitive objects.

•  Over spill protection

•  Double Conductive Shielding against bright light disturbance.

•  Transmits check-in/status signal every 8 minutes.

Product Summary

Installation Guidelines

For easier installation, programming and RF testing should be done 
before mounting to check for good communication between the 
control panel and all system devices.

Install the detector and other system devices in the order of the 
following steps:

>

  Programming/RF Testing - program detector and all other 

devices into the control panel and test RF communication from 
each intended device location to the control panel.

>

  Mounting - mount detector at the tested location.

Mounting

Use proper tools and hardware. 

>

  Mount camera between 0.8 m to 1,2 m height. 

In order to reduce false alarms, do not aim the detector toward 

vegetation, a road, or unlimited space.

Do not cover the Fresnel lens.

DOC. - REF.   213-OMV-VX

VERSION : FEBRUARY 2017

1

INSTALL SHEET

OMV-VX

 OUTDOOR VISUAL VERIFICATION DETECTOR

Summary of Contents for OMV-VX

Page 1: ...y 8 minutes Product Summary Installation Guidelines For easier installation programming and RF testing should be done before mounting to check for good communication between the control panel and all system devices Install the detector and other system devices in the order of the following steps Programming RF Testing program detector and all other devices into the control panel and test RF commun...

Page 2: ...ole use a metal band with 25 mm or less in width for pole mount 6 Remove the battery case cover and insert 3 Duracell CR123A Lithium batteries or 3 SAFT LS14500 Lithium batteries Close the battery case The OMV VX red LED is now on You can assemble the detector and and take your programming keypad to pair the OMV VX to the Videofied panel 1 2 3 4 CR123A LS15400 6 5 Wall mount Pole mount 2 INSTALL S...

Page 3: ...the detector with the Videofied panel Press and release the programming button 5 The OMV VX red LED will flash until it is paired with the panel When linked with the panel the keypad will display The OMV VX is now paired with your Videofied panel It now needs to be configured and tested Tue 29 10 11 23 DISARMED LVL 1 ACCESS LEVEL 1 ACCESS LEVEL LEVEL 1 ACCESS LEVEL LEVEL 4 OK orYES OK orYES OK orY...

Page 4: ...ssion of intrusion sabotage and video 2 The next step is to assign the detector to one of the four available areas used for delay and partial arming purposes please refer to the Videofied panel installation manual for more details about the areas 3 Enter an appropriate device name and location up to 16 characters then accept The display shows the device number and name for confirmation 4 The funct...

Page 5: ... with no tilt with a mounting height of 0 8 m to 1 2 m For optimal use the OMV VX shall detect a movement across the detection field and not toward the detector The detector shall not be pointed toward a heat source AC units sun or sun reflections or moving elements such as flags sails or vegetation that will generate false detection ...

Page 6: ...sation and environmental noise immunity Double Conductive Shielding against bright light disturbance 5 detection range adjustments Important It is essential to monitor the proper functioning of the infrared detection using the FUNCTIONAL TEST feature in the panel MAINTENANCE menu A red status LED lights up when the OMV VX is detecting Use that test to determine the pattern of the detection field ...

Page 7: ... product reset To clear the OMV VX memory in order to pair it with a new panel programming follow the procedure below 1 Remove the batteries from the OMV VX 2 Leave the battery case empty for about 30 seconds 3 Reinsert the batteries inside the OMV VX 4 Follow the programming procedure described on page 2 ...

Page 8: ...ent Adjust sensitivity for the OMV VX MotionViewer To change the OMV VX sensitivity you need to change the detector name DEVICE CONFIGURATION CHANGE NAME DEVICE OK orYES To select the OMV VX OK orYES SENSITIVITY ADJUSTMENT MINIMAL SENSITIVITY detector_name 2 LOW SENSITIVITY detector_name 1 DEFAULT SENSITIVITY detector_name HIGH SENSITIVITY detector_name 8 MAXIMAL SENSITIVITY detector_name 9 Enter ...

Page 9: ...ence to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving an...

Page 10: ... angle 90 Sensor type CMOS Daylight video Programmable Color or B W Night video Automatic black white infrared Infrared illumination Automatic with 4 IR LEDs Infrared illumination distance Up to 12m Video Video format MJPEG WMV MJPEG DIFF Frame rate 5 images per second Video duration Programmable 10 seconds by default Video resolution QVGA 320x240 Average video file size 220 kb Image Format JPEG R...

Page 11: ...symbol on the product or on its packaging indicates that this product should not be treated as household waste It must be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health The recycling of materials will h...

Reviews: