User’s Manual

Bluetooth Clinical Electrical

Thermometer

Model DT1/DT2

Summary of Contents for 7600

Page 1: ...User s Manual Bluetooth Clinical Electrical Thermometer Model DT1 DT2 ...

Page 2: ...if swallowed This device is designed for oral rectal or axillary use only Please note that temperature measuring are affected by many factors including strong physical activity before the test drinking hot or cold drinks and measurement methods Avoid taking temperature for 30 minutes after physical exercise bathing dining or drinking hot or cold beverages Stop using the thermometer if it operates ...

Page 3: ...s may be distorted if the device is used close to television microwave oven cellular telephone X ray or other devices with strong electrical fields Used equipment parts and battery are not treated as ordinary household waste and must be disposed of according to the applicable local regulations Please keep the thermometer close to the skin when measuring If it is loose the temperature measurement r...

Page 4: ...ansmission distance of this product in a barrier free environment is 10 meters If the distance exceeds this limit this product may not work properly Please use this product in the effective wireless transmission distance The battery inside this product cannot be replaced All the illustrations provided in this manual are for reference only Please refer to the actual product When the device is abnor...

Page 5: ... Meaning Application part type BF Manufacturer CE0197 In conformity with Directive 93 42 EEC European Representative Symbol for ENVIRONMENT PROTECTION Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your local authority or retailer for recycling advice IP22 Against ingress of solid foreign objects 12 5mm diameter Against dri...

Page 6: ...ou want to take your temperature again shortly press it to re measure your temperature 2 Display screen It visually displays the temperature measurement results 3 Indicator light Green light it means your body temperature is normal Yellow light it means you have a moderate fever Red light it means you have a ultra high fever 4 Probe tip No Model Temperat ure measure ment function Bluetooth transmi...

Page 7: ...7 It can measure the temperature 2 5 Screen display information Temperature display Unit Measurement ...

Page 8: ... screen will display a low power prompt Note The device cannot be used during charging When charging you must use a class Ⅱ adapter conforming to IEC EN 60601 1 and the output is DC 5V 1A If it is not followed there may be a risk of electric shock 3 2Before Measurement 1 Please long press the on key to start the product 2 Display history The history record appears on the screen indicating that the...

Page 9: ...re measuring head under your tongue 2 Close your lips gently around the thermometer 3 Keep the thermometer under your tongue until the digital thermometer beeps Measuring axillary temperature 1 Put the temperature measuring head securely in your armpit 2 Hold your arm down tightly at your side 3 Keep the thermometer in your armpit until the digital thermometer beeps Measuring rectal temperature 1 ...

Page 10: ...ce is lower than 35 or 95 the screen will display LOW with beep long sound When the temperature measured by the device is higher than 41 or 105 8 the screen will display HIGH with beep long sound 2 Turn off the thermometer press and hold 0 5 seconds to switch the thermometer off 3 If no operation is performed for more than 3 minutes the thermometer will automatically turn off It is recommended to ...

Page 11: ...a cloth dipped in a disinfectant solution such as 70 isopropyl rubbing alcohol or soap and water 2 Rinse off disinfectant residue Care and Storage Do NOT drop or crush this device is not shock proof Do NOT dismantle or modify device Do NOT store the device in an extreme environment with direct sunlight or high temperatures Store the unit in the protective case while not in use ...

Page 12: ...ve Bluetooth turned off Turn on the devices Bluetooth from the setting menu Other devices don t support the Bluetooth 4 0 BLE Change to a compatible one Inaccurate measured value The temperature measuring heads are placed in different positions resulting in different readings Check whether the thermometer is placed in the correct position as described in Using the thermometer Thermometer moves whi...

Page 13: ...n 30 minutes The device has not been placed for more than 30 minutes from the warmer environment to the measuring environment Measurements should be taken before they are left in the measuring environment for more than 30 minutes The measurement temperature exceeds 43 9 or below 30 Please use within the measuring temperature range 30 43 9 6 Accessories Model Description 540 00240 00 MICRO USB char...

Page 14: ... humidity noncondensing 15 to 85 15 to 85 Barometric 700 to 1060 hPa 700 to 1060 hPa Degree of dust water resistance IP22 Physical Size 160mm 22mm 10mm main unit Weight Less than 30 g main unit Wireless connectivity Built in Bluetooth 5 0 BLE Expected service life 5 years Power Supply Charge input Micro USB DC5V Battery type Rechargeable lithium polymer battery Battery life Operating 12 14hours fo...

Page 15: ...lsius or Fahrenheit Temperature range 32 0 43 9 89 6 111 0 Measurement accuracy Less than 35 8 0 3 Less than 96 4 0 5 35 8 to less than 37 0 2 96 4 to less than 98 0 0 3 37 0 to 39 0 0 1 98 0 to 102 0 0 2 Greater than 39 0 to 41 0 0 2 Greater than 102 0 to 106 0 00 3 Greater than 41 0 0 3 Greater than 106 0 0 5 Bluetooth RF Frequency range 2 402 2 480 GHz Max RF power 14 dBm ...

Page 16: ...s could result Portable and mobile communication equipment may affect the performance of this device Other devices that have RF transmitter or source may affect this device e g cell phones PDAs and PCs with wireless function Guidance and Declaration Electromagnetic Emissions The device is intended for use in the electromagnetic environment specified below The customer or the user of the device sho...

Page 17: ...17 power supply network that supplies buildings used for domestic purposes Voltage Fluctuations Flicker Emissions IEC 61000 3 3 Complies ...

Page 18: ...t output lines 2 kV for power supply lines 1 kV for input output lines Mains power quality should be that of a typical commercial or hospital environment Surge IEC 61000 4 5 1 kV line s to line s 2 kV line s to earth 1 kV line s to line s 2 kV line s to earth Voltage dips short Interruptions and Voltage variations on power supply input lines IEC 61000 4 11 5 UT 95 dip in UT for 0 5 cycle 40 UT 60 ...

Page 19: ...vironment guidance Conduced RF IEC61000 4 6 3 Vrms 150 kHz to 80 MHz outside ISM bands 3 Vrms 150 kHz to 80 MHz outside ISM bands Portable and mobile RF communications equipment should be used no closer to any part of the system including cables than the recommended separation distance calculated from the equation appropriate for the frequency of the transmitter Recommended separation distances P ...

Page 20: ...o cellular cordless telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the device is used exceeds the applicable RF compliance level ...

Page 21: ... according to frequency of the transmitter m 150 kHz 80 MHz P d 2 1 80 MHz 800 MHz P d 2 1 800 MHz 2 5 GHz P d 3 2 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 20 1 20 2 30 10 3 80 3 80 7 30 100 12 00 12 00 23 00 For transmitters rated at a maximum output power not listed above the recommended separation distance d in metres m can be estimated using the equation applicable to the frequency of the tr...

Page 22: ...uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on ...