background image

VANNER

 Incorporated

                                                          

Owners Manual

 

 

 

Max Battery Charger 

P

age 1 

Owner’s Manual  

 

 

Max Charger 

24Volt 42 Amp 

Three Stage Battery Charger  

 
 

Models:  SP00155, SPC0182, SPC0184 

 

 

 
 

Models:  SP00143, SP00180, SP00181, SPC0187 

 

 

 

Summary of Contents for SP00143

Page 1: ...VANNERIncorporated Owners Manual Max Battery Charger Page 1 Owner s Manual Max Charger 24Volt 42 Amp Three Stage Battery Charger Models SP00155 SPC0182 SPC0184 Models SP00143 SP00180 SP00181 SPC0187...

Page 2: ...and Checkout 5 3 1 Selection of Battery Charger Location 7 3 2 Charger Mounting 8 3 3 Routing and Connecting Battery Charger DC Output Cables 8 4 Battery Charger Operating Procedure 9 4 1 Charger Setu...

Page 3: ...lease contact your dealer or contact Vanner directly at the phone number or email address shown on the back of this manual 1 General Information 1 1 Introduction The Vanner Max Battery Charger is a hi...

Page 4: ...ge Nominal 26 6VDC 27 4VDC Ambient Temperature 40 to 105 F 40 to 40 C Cooling Forced Air 100 CFM 24VDC Fan with front to rear air flow Chassis Steel with durable painted finish Weight 35 lbs Dimension...

Page 5: ...pment tends to produce arcs and sparks during installation To prevent fire or explosion compartments containing batteries or flammable materials must be properly ventilated Safety goggles should alway...

Page 6: ...xternal conductors must use proper wire size to avoid dangerous overheating or diminished performance If the charger has been dropped or damaged in any way do not operate the charger until it has been...

Page 7: ...ediately flood eye with running cold water for at least 20 minutes Get medical attention immediately 5 NEVER smoke or allow a spark or flame near a battery Gases produced by batteries are explosive 6...

Page 8: ...to the Battery s negative terminal 2 Install a fuse in line with the positive battery source to the charger Size fuse at an 80Amp minimum to a 150A maximum 3 Battery cable connections must be clean a...

Page 9: ...ption Stage holds battery voltage at the stated bulk rate for 20 minutes Charger output current will vary as needed to hold battery voltage constant After 20 minutes Absorption Stage ends and Float St...

Page 10: ...her 120VAC is disconnected or battery is disconnected No LED s The charger is OFF and is disconnected from both 120VAC and battery LED Status Indicators for Models SP00155 SPC0182 and SPC0184 LED Char...

Page 11: ...VANNERIncorporated Owners Manual Max Battery Charger Page 11 Owner s Manual Notes...

Page 12: ...tery Charger Page 12 Owner s Manual Vanner Incorporated 4282 Reynolds Drive Hilliard Ohio 43026 1 800 AC POWER 1 800 227 6937 Tel 614 771 2718 Fax 614 771 4904 www vanner com e mail pwrsales vanner co...

Reviews: