UNIWATT is a line of products manufactured by Stelpro. For more information 

please contact customer service

.

INSUTE202NP1215 

NON PROGRAMMABLE 

ELECTRONIC THERMOSTAT  

USER

’S GUIDE

UTE202NP SERIES 

Summary of Contents for UTE202NP Series

Page 1: ...I T É C ERTIFIÉ REGISTERED Q U A L I T Y S Y S T E M UNIWATTis a line of products manufactured by Stelpro For more information pleasecontactcustomerservice INSUTE202NP1215 NON PROGRAMMABLE ELECTRONIC THERMOSTAT USER S GUIDE UTE202NP SERIES ...

Page 2: ...ct this product to a supply source other than 120 VAC or 240 VAC and do not exceed the load limits specified Protect the heating system with the appropriate circuit breaker or fuse You must regularly clean dirt accumulations on the thermostat Do NOT use fluid to clean thermostat air vent Do not install thermostat in a wet place However installing it in isolated walls is allowed Note When a part of...

Page 3: ...20 240 VAC It possesses a user friendly interface Furthermore it gives you the possibility to control the temperature of a room with great precision THIS THERMOSTAT IS NOT COMPATIBLE WITH THE FOLLOWING INSTALLATIONS electrical current higher than 8 3 A with a resistive load 2000 W 240 VAC and 1000 W 120 VAC electrical current lower than 1 25 A with a resistive load 300 W 240 VAC and 150 W 120 VAC ...

Page 4: ...w on an external wall or close to a door leading outside exposed directly to the light or heat of the sun a lamp a fireplace or any other heat source close or in front of an air outlet close to concealed ducts or a chimney and in a location with poor air flow e g behind a door or with frequent air drafts e g head of stairs THERMOSTAT MOUNTING AND CONNECTION 1 Cut off power supply on lead wires at ...

Page 5: ...derless connectors When making the connection with aluminum wire make sure that you are using connectors identified CO ALR Please note that the thermostat wires do not have polarity Therefore the way they are connected is not important 2 WIRE INSTALLATION 4 WIRE INSTALLATION ...

Page 6: ... of the thermostat b Using a flat screw driver insert the screw driver in the side slot at the top right corner of the thermostat and turn delicately until the door is freed 5 Place all the wires inside the electrical box 6 Fix the thermostat to the electrical box using the two screws provided 7 Close the thermostat door 8 Turn on the power ...

Page 7: ...increments of 0 5 C 1 F To quickly scroll through the set point values press and hold down the button The minimum set point is 3 C 37 F and the maximum set point is 30 C 86 F When you press a button the current set point is shown and the flashes You can turn off the thermostat by lowering the set point below 3 C 37 F The set point value displayed will be and heating system start up will be impossi...

Page 8: ...hrenheit and conversely The degree Celsius or Fahrenheit symbol will be displayed 3 When the adjustment is completed release the buttons and wait for 5 seconds to exit the adjustment function HEATING POWER INDICATOR The level of power used to maintain the temperature at the set point is expressed as a percentage indicated by the number of bars in the thermometer displayed The heating power used is...

Page 9: ...IVATE THE SECURITY MODE 1 To deactivate the Security mode start by cutting off the thermostat power at circuit breaker and wait at least 20 seconds 2 Turn the thermostat power back on and the icon will blink for a maximum of 5 minutes 3 Simultaneously press down both buttons for 13 seconds After 13 seconds the icon will disappear and the degrees symbol C or F will stop blinking indicating that the...

Page 10: ...on Then you must press down the bottom button for 3 seconds until the icon blinks A duration in seconds will appear You can adjust it from 90 factory setting to 300 seconds by increments of 30 seconds Once the adjustment is done you can exit the adjusment mode by not pressing down any button during 5 seconds PARAMETERS SAVING AND POWER FAILURES The thermostat saves some parameters in a non volatil...

Page 11: ...few minutes and then turns on again The thermal protection of the heating unit has opened due to overheating Check if the heating unit is in good condition of operation and that clearance around the ap pliance is according to the manufacturer s specifications The display has low contrast when heating is on The load is lower than the minimum load Install a heating unit that is within the load limit...

Page 12: ...nsible for any damage resulting from this modification The warranty is limited to the factory repair or the replacement of the unit and does not cover the cost of disconnection transport and installation E mail contact stelpro com Web site www stelpro com L I M I T E D W A R R A N T Y L I M I T E D STELPRO DESIGN INC Saint Bruno de Montarville Québec J3V 6L7 SUPPLY VOLTAGE 120 208 240 VAC 50 60 Hz...

Reviews: