background image

Cronotermostato

Digitale

TUO WI-FI BATTERIA

Manuale d’Uso

User Manual

DIGITAL CHRONOTHERMOSTAT

Summary of Contents for Tuo Wi-Fi Batteria Bianco

Page 1: ...Cronotermostato Digitale TUO WI FI BATTERIA Manuale d Uso User Manual DIGITAL CHRONOTHERMOSTAT...

Page 2: ......

Page 3: ...de Pagina 62 regulation type Pagina 63 parameters for regulation type Pagina 63 antifreeze temperature Pagina 64 adjustment of the measured temperature Pagina 64 Wi Fi NET modem Pagina 65 device addre...

Page 4: ...ring the initial configuration this choice can however be changed by the user at any time Code Model Description VE788600 TuoWi Fi Batteria Bianco Wi Fi chronothermostat with batteries colour white VE...

Page 5: ...programming updates The basic setting factory configuration requires the device to log in to the cloud in the winter period from October 1st to April 30th once every 15 minutes in the time slot from 6...

Page 6: ...English 42 Tuo Wi Fi Batteria Chronothermostat User Manual DIMENSIONS 130 85 28 CONNECTION DIAGRAM NC NO C...

Page 7: ...T3 h Active timed operation Connection to the Vemer Cloud in progress Connection to the active Wi Fi network Configuration menu ADV advanced parameters of the device TIMER timings SET automatic operat...

Page 8: ...ess or total lack of ventilation to avoid that the reading of the temperature measured by the probe is in some way offset Device installation Preliminary operations If you intend to use the device by...

Page 9: ...e in the base and fix the latter to the wall or to cover the 3 module recessed box using the supplied screws B 3 connect the relay to the boiler or air conditioner control circuit C 4 close the cover...

Page 10: ...onnection between the app and the device 5 Select the home Wi Fi network to which to connect the device Enter the password of the Wi Fi network and choose Next Important before proceeding make sure th...

Page 11: ...ow the icon to indicate the successful connection between the app and the device 5 Enter the full name of the home Wi Fi network to which to connect the device and the password and click Next Importan...

Page 12: ...the seconds reset only Set the minutes Set the time Set the year Set the month Set the day To exit the date and time setting press the key for a long time to return to the home screen to change the s...

Page 13: ...ting mode Tap to change the operating mode heating air conditioning and the mode automatic manual off Measured temperature 25 0 C Operation mode HEATING System status red on grey off Thermostats list...

Page 14: ...to any other day of the week Copy function It is also possible to set a delay of switching by tapping on the desired time To know what a switching delay is see page 59 Modify a program Program managem...

Page 15: ...re threshold and low battery warning regulation type blocking of local operation the time zone battery management energy saving From this screen you can enter the email of the user who will receive th...

Page 16: ...to obtain the MAXIMUM energy saving by turning off the wifi modem The switching off and on of the modem can only be done the thermostat menu scheduled With this function you can set the frequency wit...

Page 17: ...le the device adjusts the temperature based on the value of T2 from 00 00 to 6 00 and from 8 00 to 17 00 T3 from 6 00 to 8 00 and from 17 00 to 21 00 T1 from 21 00 to 24 00 The values of T1 T2 and T3...

Page 18: ...ic operation Off operation 3 3 Manual operation Tm operation Automatic operation Manual operation 3 Automatic operation Tm operation Automatic operation Off operation 3 3 NOTE when operating on the ke...

Page 19: ...es of the automatic operation T1 T2 T3 The TIMER menu allows setting of one of the 3 timed operations The PROG menu allows you to change the programming of the automatic operating mode The ADV menu al...

Page 20: ...vice acquires the date and time settings from the server and no settings are required If instead the device is not connected to the Wi Fi network proceed as follows To exit the date and time setting p...

Page 21: ...l the summer time change winter time is identified by the symbol For example in Italy the summer time starts the last LST Sunday 7 of March 03 at 2 00 o clock and the last LST Sunday 7 of October 10 a...

Page 22: ...ram for one or more days of the week modify one or more existing programs by personalizing the profile that is assigning different temperature levels for one or more hours of the day How to choose a d...

Page 23: ...to set delays of 15 30 45 minutes independent for every hour of the day How to customize the profile of a Px program starting from midnight 00 00 press the keys and to assign to each hour of the day o...

Page 24: ...5 C T2 15 C T3 18 C heating winter operation T1 off T2 23 C T3 25 C conditioning summer operation How to change the temperature values T1 T2 T3 To exit the temperature change press the key once to re...

Page 25: ...Timed automatic set a timing during the automatic operation to maintain this operation until the timing has elapsed At the end of the timing the device activates the off operation Off timed set a tim...

Page 26: ...oposed in sequence Press the keys and to change the value of the selected parameter the key to go to the next parameter the key to exit and confirm the changes Note the device exits the menu after abo...

Page 27: ...ion on the characteristics of the on off and proportional regulation logic see Regulation types on page 71 Parameters for the regulation type this menu varies depending on the chosen regulation type I...

Page 28: ...g excludes the antifreeze function in this case when the device is off no minimum temperature is guaranteed Adjustment of the measured temperature In particular installation conditions it can happen t...

Page 29: ...been connected to a Wi Fi network attempts to connect to the Wi Fi network with the previously saved parameters The symbol on the home screen indicates the connection status On fixed modem on and devi...

Page 30: ...s the quality of the connection with the access point values higher than 60dB excellent signal quality values between 60dB and 90dB good signal quality values below 90dB poor signal quality which coul...

Page 31: ...alue 2 C HIis the upper limit Allowed values L0 50 C Factory value 50 C Activation deactivation of the keypad lock Under particular installation conditions for example in public buildings hotels etc i...

Page 32: ...om 0h Battery charge level Indicates the battery charge level as a percentage For values greater than 20 Guaranteed operation no alarm signal For values below 20 the device display flashes the Home sc...

Page 33: ...etting 3 Keypad unlock When the key lock is active the device adjusts the temperature using the set programming In this condition after pressing a key the display shows the writing bLOc To unlock the...

Page 34: ...lay shows all the segments keep the key pressed until dEF appears SET 3s SET 3s 3 Initial screen Configuration menu Operationmode heating winter Regulationtype on off Differential on off 0 3 C Band pr...

Page 35: ...d that a low differential 0 1 C 0 2 C leads as a consequence more frequent ignitions of the system but the temperature will be more uniform than a high value 0 9 C 1 C Proportional regulation only for...

Page 36: ...g time on the icon that identifies the device in question until the request for confirmation of deletion appears 2 Perform the device configuration procedure with the new user account If you replace t...

Page 37: ...minutes independent for each hour Measured temperature scale 0 C 50 C Measured and displayed temperature resolution 0 1 C Temperature regulation range 2 0 C 50 C Measurement update every 20 seconds Me...

Page 38: ...0 21 22 23 P3 T3 T2 T1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 P4 T3 T2 T1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 P5 T3 T2 T1 0 1 2 3 4 5 6 7 8 9 10 11 12...

Page 39: ...0 21 22 23 P3 T3 T2 T1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 P4 T3 T2 T1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 P5 T3 T2 T1 0 1 2 3 4 5 6 7 8 9 10 11 12...

Page 40: ...V3ISO1092 010 Vemer S p A I 32032 Feltre BL Via Camp Lonc 16 Tel 39 0439 80638 Fax 39 0439 80619 e mail info vemer it web site www vemer it 07 2021...

Reviews: