background image

Cronotermostato

Digitale

Mithos

Manuale d’Uso

User Manual
DIGITAL PROGRAMMABLE THERMOSTAT

Summary of Contents for VE312500

Page 1: ...Cronotermostato Digitale Mithos Manuale d Uso User Manual DIGITAL PROGRAMMABLE THERMOSTAT...

Page 2: ......

Page 3: ...ons Page 37 Initial start up Reset Page 39 Clock setting Page 39 Programs setting Page 41 Temperatures setting Page 43 Manual operation Page 44 Summer winter operation Page 45 Keypad On Off command Pa...

Page 4: ...PTIONS ARE ENSURED BOTH IN winter and in summer heating air conditioning s NTERCHANGEABLE SILVER COLORED FRONT PANEL AVAILABLE AS ACCESSORY CODE 6 s NSTALLATION CAN BE WALL OR BOX COVERAGE MODULES s I...

Page 5: ...ssible the conditions of average temperature of the entire environment Avoid installing too close to doors windows heat sources direct sunlight radiation and positions with excess or total lack of air...

Page 6: ...English 34 Mithos Programmable Thermostat User Manual DIMENSIONS T3 T2 T1 132 95 26 CONNECTION DIAGRAM 1 2 3 4 5 6 7 X Temp X Code COM NA NC...

Page 7: ...s Power supply 1x1 5V AA stilo alkaline battery s ATTERY LIFE ABOUT MONTHS s HARGE RESERVE MINUTE FOR BATTERY REPLACEMENT s ATTERY CHARGE LEVEL INDICATION s UXILIARY INPUTS telephone activator X Temp...

Page 8: ...NTER OR SUMMER OR MANUAL OPERATION s PTIONAL DISPLAY IN s UTOMATIC CHANGE 4 34 s 0ASSWORD PROTECTED KEYPAD LOCK FOR INSTALLATION IN PUBLIC PLACES s 7ALL MOUNTING OR ON TYPE BOX s 4ERMINAL STRIPS Outpu...

Page 9: ...activation and deactivation of the programmable thermostat 6 EY selects temperature 4 7 EY selects temperature 4 EY selects temperature 4 9 EY allows to set a timer or an activation delay EY programs...

Page 10: ...XTERNAL TEMPERATURE Field NVIRONMENT TEMPERATURE Field 3ET PROGRAM Field ANUAL OPERATION ACTIVATION Field 4IMER Field IR CONDITIONING ACTIVATION Field EATING ACTIVATION Field LOCK Field 0HONE DIAL Fi...

Page 11: ...ion IF THE CLOCK IS NOT SET THE PROGRAMMABLE THERMOSTAT will not adjust it will start doing SO ONLY ONCE THE CLOCK IS SET CLOCK SETTING s Press the key on eld seconds will run ashing while eld will di...

Page 12: ...r the hours is set eld will display a ashing value of the year eld the value of the month and eld the value of the day Press the and keys to modify the values and to con rm Once the day is set press t...

Page 13: ...e selected program is correct press the key to continue to the next day s F THE SELECTED PROGRAM IS NOT CORRECT FOR that day you can create another one using the and keys which modify value 0X contain...

Page 14: ...hour to the next without modifying the set temperature Pressing the key it is possible to set the activation delay for that speci c hour Each pressure of the key increases the delay by 15 minutes Pre...

Page 15: ...eld to display the writing corresponding to the temperature that is being modi ed on eld the value of the aforementioned temperature will ash With the and keys it is possible to modify the value and...

Page 16: ...emperature value will ash With the and keys it is possible to change the value from 2 0 C to 35 C Pressing the key or after 45 seconds from the last operation eld will display the value of the environ...

Page 17: ...ymbol or will appear With the and keys it is possible to select one of the two operations The program will go to the desired operation pressing the key or after 45 seconds from the last operation The...

Page 18: ...vation press the key again OTE 4HIS COMMAND HAS A HIGHER PRIORITY THAN THE TELEPHONE ACTIVATOR COMMAND THEREFORE IF THE DEVICE IS DEACTIVATED USING THE KEY IT WILL NOT BE POSSIBLE TO activate deactiva...

Page 19: ...h off status will be maintained until the end of the timing operation will then switch to the one active before deactivation If during timing the system is activated the timing ends In all cases the t...

Page 20: ...tery charge status s IELD will display the writing R and on eld letter O ON OFF programming or P proportional programming will ash s 4O ENTER ADVANCED PROGRAMMING PRESS the PRG key for more than 3 sec...

Page 21: ...e value The range varies from 0 1 C to 1 C s N CASE OF PROPORTIONAL regulation type the parameters to be set are regulation band regulation period Field will display the writing BND and on eld the val...

Page 22: ...10 0 C It is also possible to disable the antifreeze function holding the key until eld displays the symbol In this case when the programmable thermostat is off no regulation is executed 4EMPERATURE...

Page 23: ...the probe are the following s EGREE OF PROTECTION 0 s ABLE LENGTH METERS EXTENSIBLE UP TO METERS WITH A BIPOLAR CABLE min section 1 mm2 s PERATING TEMPERATURE ODE ODEL APACITY 6 X Temp 40 C 60 C HOOS...

Page 24: ...please refer to the chapter ADVANCED FUNCTIONS 3YSTEM OPERATION HOURS It is possible to display the system operation hours relay in ON status Field displays the writing TOT while elds and will display...

Page 25: ...estored after 45 seconds 6 5 4 3 Automatic change CET DST The programmable thermostat allows to automatically move from the CET Central European Time to DST Daylight Saving Time and vice versa Holding...

Page 26: ...ormal view The default values set for the automatic time change are winter summer change last Sunday of March at 02 00 summer winter change last Sunday of October at 03 00 4ELEPHONE ACTIVATOR COMMAND...

Page 27: ...lay the value relevant to the external probe while eld will display the value relevant to the internal one To reset the minimum maximum value memorized press the key for at least 3 seconds EYPAD LOCK...

Page 28: ...e ned regulation cycle on the basis of the gap of the temperature measured by the setpoint value The necessary parameters for the de nition of this mode are s THE REGULATION BAND s THE REGULATION PERI...

Page 29: ...M THERMAL INERTIA SYSTEMS s g FOR HIGH THERMAL INERTIA SYSTEMS Choose the regulation band value as follows s BROAD BAND FOR SYSTEMS WITH HIGH THERMAL GRADIENT s NARROW BAND FOR SYSTEMS WITH LOW THERMA...

Page 30: ...g display Beyond this time date and time will be lost and must be reset upon next activation However the executed programs will remain memorized The use of strictly alkaline batteries is recommended A...

Page 31: ...N 4 N N N N N N N N N N N N N N N N N N N N N N N N 4 N N N N N N N N N N N N N N N N N N N N N N N N 4 6 7 9 P4 4 N N N N N N N N N N N 4 N N N N N N N N N N N N N N N N N N N N N N N N 4 N N N N N N...

Page 32: ...N N N 4 N N N N N N N N N N N N N N N N N N N N N N N N 4 N N N N N N N N N N N N N N N N N N N N N N N N 4 6 7 9 P4 4 N N N N N N N N N N N N N 4 N N N N N N N N N N N N N N N N N N N N N N N N 4 N...

Page 33: ......

Page 34: ...V3ISO0520 011 Vemer S p A I 32032 Feltre BL Via Camp Lonc 16 Tel 39 0439 80638 Fax 39 0439 80619 e mail info vemer it web site www vemer it...

Reviews: