background image

Owner's Manual

Infrared Forehead Thermometer

Model

   DET-3018c

Contents

Introduction

1

2

Please read all instructions carefully and thoroughly 

before using this product.

Indication for Use:

 The infrared forehead thermometer is a non-contact

infrared thermometer intended for the intermittent measurement of 

human body temperature from forehead at a distance of 1~5cm by people

of all ages. This thermometer is reusable for home use and clinical use 

and can be reused by many people.

The DET-3018c infrared forehead thermometer is specifically 

designed for safe use on the forehead. The Infrared Forehead 

Thermometer is a device capable of measuring people's body 

temperature by detecting the intensity of infrared light emitted from 

the forehead. It converts the measured heat into a temperature reading 

displayed on the LCD. When properly used, it will quickly assess your 

temperature in an accurate manner.

Introduction  ........................................................02
Warning  ....................................................................03
Product Description  ................................................. 04
LCD Display Introduction    ....................................... 05
Basic  Functions  ...................................................  06 
Forehead Thermometer Advantages   ......................... 07
Real  Time  Clock  Setting    ......................................08
Temperature  Taking  Hints  ...................................11
Illustration  For  Use  ..............................................13
Memory  Mode  ........................................................18
Care  And  Cleaning  ...............................................19
Battery  Replacement  ............................................20
Specifications  .....................................................21
Troubleshooting  ...................................................22
Calibration  ...........................................................24
Symbol  Explanation  ...........................................25
Service  ...............................................................26
Warranty  ...............................................................27

Information 

Electromagnetic Compatibility Information  ...............30

FCC 

..........................................................28

Document No.: 

Article No.: 

Version:

Date of Issue: 

JDET-1804-011

004

2021-11

 Z

This appliance conforms to the following standards:
ASTM E1965-98 Standard Specification for Infrared Thermometers 
for Intermittent Determination of Patient Temperature,
ISO 80601-2-56 Medical electrical equipment —Part 2-56:
Particular requirements for basic safety and essential performance
of clinical thermometers for body temperature measurement,
IEC 60601-1-11 Medical electrical equipment —Part 1-11: General 
requirements for basic safety and essential performance –Collateral
Standard: Requirements for medical electrical equipment and 
medical electrical systems used in the home healthcare environment
and complies with the requirements of IEC 60601-1-2(EMC) ,
AAMI ANSI ES60601-1(Safety) standards. And the manufacturer 
is ISO 13485 certified.

Telephone: +86-571-81957767

Fax: +86-571-81957750

JOYTECH Healthcare Co., Ltd.

No.365, Wuzhou Road, Yuhang Economic Development Zone,

Hangzhou ,  Zhejiang 311100 China

Made in China

Summary of Contents for DET-3018c

Page 1: ...08 Temperature Taking Hints 11 Illustration For Use 13 Memory Mode 18 Care And Cleaning 19 Battery Replacement 20 Specifications 21 Troubleshooting 22 Calibration 24 Symbol Explanation 25 Service 26 Warranty 27 Information Electromagnetic Compatibility Information 30 FCC 28 Document No Article No Version Date of Issue JDET 1804 011 004 2021 11 Z This appliance conforms to the following standards A...

Page 2: ...uetooth sign If the APP is successfully connected to the machine the Bluetooth sign will always be on otherwise it will keep flashing Real Time Clock Forehead Mode Object Mode Memory Mode There are 30 sets memories for forehead and object measurements Each memory also records the measurement date time mode icon Switch Please see the Real Time Clock Setting to learn how to change between Celsius an...

Page 3: ...ither an AM PM 12 hour or a 24 00 24 hour format Press and release button to select the format With the preferred time format on the display press Button the Hour figure is flashing automatically Test Setting When installing the battery please set the parameters of the thermometer With the thermometer off press and hold Button to enter into setting mode Setting Set the minute Press and release the...

Page 4: ...nt temperature for at least 10 minutes before taking a reading 3 Users should not drink eat or be physically active such as bathing showering shampooing and hair drying before while taking the measurement Remove hat and hair and wait 10 minutes before taking a reading 4 Oils or cosmetics on the forehead may give a lower temperature reading than the actual one Remove dirt from the forehead before t...

Page 5: ...ry life 2 Clean the probe after each use to ensure an accurate reading and avoid cross contamination See the section of Care and Cleaning for details 30 seconds BackLight In Forehead mode 1 The display will be lighted for 3 seconds when the unit is ready for measurement and the display will be lighted GREEN for 3 seconds when a measurement is completed with a reading less than 37 3 99 1 2 The disp...

Page 6: ...ttery when appears in the right corner upper of LCD display See Figure 7 2 Slide battery cover down as shown in Figure 8 3 Remove battery and install 2 new AAA alkaline batteries as shown in Figure 9 4 Slide battery cover back on Figure 7 Figure 8 Figure 9 Specifications Forehead mode 34 0 43 0 93 2 109 4 Object mode 0 100 32 212 Forehead mode 0 2 0 4 during 35 5 42 0 95 9 107 6 at 15 35 59 0 95 0...

Page 7: ...n Storage and Transportation 15 95 RH Humidity limitation The first num 2 Protected against solid foreign objects of 12 5 mm and greater The second num 2 Protection against vertically falling water drops when ENCLOSUREtilted up to 15 IP22 Troubleshooting In Forehead mode Temperature taken is higher than 43 0 109 4 In Object mode Temperature taken is higher than 100 212 Problem Solution The thermom...

Page 8: ...rient or relocate the receiving antenna Increase the distance between the equipment and the receiver Connect the equipment to an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help FCC Information Thermometer is warranted by manufacture to be free from defects in material and workmanship under normal use and s...

Page 9: ...d in the frequency range 80 MHz to 2 7 GHz are intended to decrease the likelihood that mobile portable communications equipment could cause interference if it is inadvertently brought into patient areas For this reason an additional factor of 10 3 has been incorporated into the formulae used in calculating the recommended separation distance for transmitters in these frequency ranges c Field stre...

Page 10: ...erify normal operation The use of accessories and power cord other than those specified with the exception of cables sold by the manufacturer of the equipment or system as replacement parts for internal components may result in increased emissions or decreased immunity of the equipment or system Electromagnetic Compatibility Information Electromagnetic Compatibility Information Electromagnetic Com...

Reviews: