MODEL: AP130

Owner’s Operation and Instruction Manual

SAVE THESE INSTRUCTIONS

THIS MANUAL WILL HELP YOU TO OBTAIN EFFICIENT, DEPENDABLE SERVICE FROM THE HEATER, AND ENABLE YOU 

TO ORDER REPAIR PARTS CORRECTLY. KEEP IN A SAFE PLACE FOR FUTURE REFERENCE.

United States Stove Company

227 Industrial Park Road

South Pittsburg, TN 37380

•  Please read this entire manual before installation and use of this 

appliance. Failure to follow these instructions could result in property 

damage, bodily injury, or even death.

• 

Contact your local building or fire officials about obtaining permits, 

restrictions and installation inspection requirements in your area.

•  Save these instructions.

• 

If  your  heater  is  not  properly  installed,  a  house  fire  may  result.  For 

everyone’s safety, follow all Installation and Operating Directions. 

Never use makeshift compromises during the installation of this 

appliance.  Contact  your  local  building  or  fire  officials  about 

restrictions and installation inspection requirements in your area.

This unit is not intended to be used as a 

primary source of heat. 

Certified to ASTM E 1509, 2012, and Certified to 

ULC S627, 2000, and(UM) 84-HUD

U.S. Environmental Protection Agency 

Certified to comply with 2015 particulate 

emissions standards.

Summary of Contents for ASHLEY AP130

Page 1: ...URE REFERENCE United States Stove Company 227 Industrial Park Road South Pittsburg TN 37380 Please read this entire manual before installation and use of this appliance Failure to follow these instruc...

Page 2: ...The closed container of ashes should be placed on a non combustible surface or on the ground well away from all combustible materials pending final disposal The exhaust system should be checked monthl...

Page 3: ...no greater than 1 5 not less than 8 200 BTU lb moisture under 8 by weight ash under 1 by weight and salt under 300 parts per million Pellets that are soft contain excessive amounts of loose sawdust h...

Page 4: ...an NFI certified specialist IMPROPER INSTALLATION The manufacturer will not be held responsible for damage caused by the malfunction of a stove due to improper venting or installation Call 800 750 272...

Page 5: ...m CORNER D Adjacent wall to unit 8 00 203mm ALCOVE E Alcove depth 36 00 914mm 5500 M only F Alcove height 60 00 520mm CLEARANCES Your pellet stove has been tested and listed for installation in reside...

Page 6: ...the stove use a 3 inch to 4 inch adapter for 4 inch pipe Connection at back of stove must be sealed using Hi Temp RTV Use 4 inch vent if the vent height is over 12 feet or if the installation is over...

Page 7: ...ith a kit that will handle most of this installation which will include a wall thimble that will allow the proper clearance through a combustible wall Once outside the structure a 3 in 76mm clearance...

Page 8: ...g of the detector when reloading In addition to the previously detailed installation requirements mobile home installations must meet the following requirements The heater must be permanently bolted t...

Page 9: ...er of this manual Because a forced draft pressure is required for the combustion process inside your stove it is extremely important that the exhaust system be properly installed and maintained And th...

Page 10: ...at will not properly control the unit When adjusting the Draft Fan setting try only 1 setting above or below the heat setting It is better to leave the stove in the automatic mode ROOM FAN The room fa...

Page 11: ...the preselected desired heat range setting 1 to 5 and the minimum heat range setting of 1 The T Stat will not turn the stove on and off When the desired room temperature has been reached and the T Sta...

Page 12: ...4 Auger Output Test The display will show augr The auger motor is turned on full If the Auger Fuse is not blown and the fuse detection circuit is functioning the Heat Range LED will be lit and the ot...

Page 13: ...urely closed the safety pressure switch will not allow the stove to feed fuel if there is no draft pressure inside the stove 7 Press the ON button on the control pad and set the heat Setting to your d...

Page 14: ...ON button on the digital control panel your stove will begin to feed fuel and automatically start within 5 minutes TAMPER WARNING This wood heater has a manufacturer set minimum low burn rate that mus...

Page 15: ...this could damage the glass DO NOT abuse the door glass by striking slamming or similar trauma Do not operate the stove with the glass removed cracked or broken FALL START UP Prior to starting the fir...

Page 16: ...s down Hopper is empty refill the hopper Loss of draft pressure Make sure that the viewing door is closed and sealed properly If not adjust door catch and or replace door gaskets Check that all outsid...

Page 17: ...g the lighting stage Quickly changes twice per second Flashing Heat Range Setting Indicator This indicates that the stove is in normal operation and that an over temperature condition exists causing t...

Page 18: ...18 GRAY BLACK Wiring Diagram CORRECT WRONG Insure the wires are connected to the bottom two prongs of the hopper switch as shown...

Page 19: ...40 Lock Nut 2 16 25480MB Access Panel 1 17 80461 Power Supply Cord 1 18 80462 Receptacle 3 Prong 1 19 891164 Auger Housing Weldment 1 20 891141 Auger 1 21 891189 Top Bushing Plate 1 22 891132 Bushing...

Page 20: ...20 11 3 2 1 5 6 4 7 9 8 10 12 Parts Diagram 47 46 48 49...

Page 21: ...07 Date _____________________ Engineer Name ________________________________ License No ____________________________________ Company _____________________________________ Telephone No _______________...

Page 22: ...s pi ces d tach es Gardez ce manuel dans un lieu s r pour toute consultation ult rieure Lorsque vous nous crivez donnez toujours le num ro de mod le complet qui se trouve sur la plaque signal tique fi...

Page 23: ...____________________________ Service de 07 Date _____________________ Nom de l ing nieur ____________________________ N de licence _________________________________ Compagnie _________________________...

Page 24: ...2 15 83542 4 40 crou 2 16 25480MB Panneau D acc s 1 17 80461 Cordon D alimentation 1 18 80462 R ceptacle 3 Prong 1 19 891164 Auger Logement Weldment 1 20 891141 Vrille 1 21 891189 Top Bushing Plate 1...

Page 25: ...20 Sch ma des pi ces 11 3 2 1 5 6 4 7 9 8 10 12 47 46 48 49...

Page 26: ...SOSTAT MARRON MARRON NOIR BLANC ROUGE BLEU ORANGE PRISE MOLEX AU CIRCUIT IMPRIM PCB PRINCIPAL NOIR NOIR NOIR BLANC BLANC SOUFFLANTE DE DISTRIBUTION VENTILATEUR D VACUATION THERMISTOR Sch ma de c blage...

Page 27: ...Cela indique que le po le fonctionne normalement et qu une condition de temp rature excessive existe provoquant l arr t du combustible Indicateur de r glage du niveau de chaleur Heat Range clignotant...

Page 28: ...e V rifiez que le raccordement du pressostat au foyer ne contienne aucune cendre ni obstruction Le syst me vis sans fin est bloqu ou il y a une vo te de combustible dans la tr mie qui emp che le combu...

Page 29: ...le et d paisseur correctes doivent tre utilis es NE substituez PAS le verre avec des mat riaux alternatifs Contactez votre revendeur autoris pour obtenir ce verre R installez le nouveau verre en le fi...

Page 30: ...fi peut effectuer ces travaux Il est aussi recommand qu avant chaque saison de chauffage le syst me complet soit inspect nettoy et si n cessaire r par par un professionnel Pour nettoyer la chemin e d...

Page 31: ...sur le bouton OFF arr t et ensuite de nouveau sur le bouton ON marche pour commencer une nouvelle s quence de mise en route 2 Si le po le a refroidi il se r initialisera l tat OFF arr t ce moment l vo...

Page 32: ...de l eau sal e 11 Bois non s ch ou 12 Produits du papier carton contreplaqu ou panneau de particules L interdiction de br lage de ces mat riaux n interdit pas l utilisation d allume feu compos s de pa...

Page 33: ...fin se met en marche plein r gime Si le fusible de la vis sans fin n a pas saut et que le circuit de d tection fusible fonctionne le voyant DEL Heat Range du degr de chaleur sera allum et les trois au...

Page 34: ...justez le r glage du ventilateur de tirage essayez seulement 1 r glage au dessus ou en dessous du r glage de chaleur Il est pr f rable de laisser le po le en mode automatique VENTILATEUR DE LA PI CE L...

Page 35: ...rage forc e est n cessaire au processus de combustion l int rieur de votre po le il est extr mement important que le syst me d vacuation soit install correctement et maintenu Et que lors du fonctionne...

Page 36: ...ionn de la plage de chaleur d sir e 1 5 et le r glage de la plage de chaleur minimale de 1 Le T Stat n allumera ni ne teindra le po le Lorsque la temp rature ambiante souhait e est atteinte et que le...

Page 37: ...s parois et du plafond toit de la maison mobile doit tre maintenue Un d tecteur de fum e fonctionnel doit tre install dans la m me pi ce que ce produit Il doit tre install au moins 15 pieds 4 57 m de...

Page 38: ...rd en T de regard devra tre plac sur le tuyau avec une sortie 90 degr s hors de la maison ce point une partie de tuyau de 3 pieds 0 91m minimum devra tre ajout e avec un couvercle horizontal qui devra...

Page 39: ...e doit tre scell en utilisant un produit vulcanis RTV pour temp ratures lev es Utilisez une ventilation de 4 pouces si la hauteur de ventilation est sup rieure 12 pieds ou si l installation se trouve...

Page 40: ...re minimum plus grand afin d obtenir un acc s commode au panneau de contr le FIGURE 3 D GAGEMENTS DE LA PAROI LAT RALE INSTALLATION EN PARALL LE FIGURE 4 D GAGEMENTS DE LA PAROI LAT RALE INSTALLATION...

Page 41: ...cialiste certifi NFI NE CONNECTEZ PAS CETTE UNIT UN CONDUIT OU CIRCUIT DE DISTRIBUTION D AIR INSTALLATION INCORRECTE Le fabricant ne sera pas tenu responsable des dommages caus s par un dysfonctionnem...

Page 42: ...ar pied cube diam tre de 1 4 5 16 po longueur non sup rieure 1 5 moins de 8 200 BTU lb humidit inf rieure 8 en poids cendres inf rieure 1 en poids et sel inf rieur 300 parties par million Les granul s...

Page 43: ...d entretien ou de nettoyage Les cendres doivent tre jet es dans un conteneur m tallique avec un couvercle d ajustement serr Le conteneur ferm dans lequel se trouvent les cendres devra tre plac sur un...

Page 44: ...d un permis de construire Cet appareil n est pas destin tre utilis en tant que principale source de chaleur U S Environmental Protection Agency Certifi aux normes d missions de 2015 particules United...

Reviews: