background image

Thermic Distribution Europe / 5 Rue du Lion - 5660 Couvin - Belgium

IQ33#6700A

WOODBOX

®

 TECHNOLOGY

Instructions

Summary of Contents for WOODBOX IQ 33

Page 1: ...Thermic Distribution Europe 5 Rue du Lion 5660 Couvin Belgium IQ33 6700A WOODBOX TECHNOLOGY Instructions ...

Page 2: ...Instructions Thermic Distribution Europe s a 5 rue du Lion 5660 Couvin Belgique 2 ...

Page 3: ...atures and burns Supervise children when they are in the same room as the appliance The appliance must be thoroughly inspected and the chimney must be swept at least once a year However in the event of improper installation malfunction or poor quality fuels the chimney must swept more often DO NOT OVERHEAT THE APPLIANCE IF A PART OF THE APPLIANCE OR THE FLUE BECOMES RED THE APPLIANCE IS OVERHEATIN...

Page 4: ... IQH33 IQH43 L mm 584 692 442 584 692 H1 mm 695 717 908 961 897 H2 mm 643 668 868 909 845 h mm 644 666 871 912 848 I mm 583 691 442 583 691 P mm 450 498 444 450 498 b mm 371 421 379 371 421 a mm 249 280 232 249 280 D mm 150 180 150 180 180 d mm 120 120 100 120 120 ...

Page 5: ...width 25 mm 618 661 726 683 476 886 618 927 726 863 frame 4 sides width 25 mm 618 678 726 700 476 903 618 944 726 880 frame 3 sides width 50mm 668 686 776 708 526 911 668 952 776 888 frame 4 sides width 50mm 668 728 776 750 526 953 668 994 776 930 IQ43 IQH13 IQH33 IQH43 type of frame IQ33 ...

Page 6: ...tight and made of non combustible materials protected if possible against oxidation enamelled sheet metal aluminium stainless steel The chimney must be high enough and constructed to avoid backdraft It should be protected with insulating materials to lower the risk of sooting in the high part of the chimney flue and if necessary it should be covered to avoid rain water from penetrating The chimney...

Page 7: ...ossible to remove the deflectors To access the deflectors you must first remove the filters Case 1 hot air comes only from the front leave the two deflectors and the filters in place Case 2 hot air comes from the tubes and from the front at the same time Remove the cover 6 screws Remove the two steel deflectors Replace the stop gap with the steel flue outlets Observe that for IQ33 IQH33 IQ43 and I...

Page 8: ...emove the two screws present under the stoppers Move the original frame back by 6mm Attach the optional frame 4 screws To attach one of the optional frames proceed as follows fixing screw of original frame fixing screw of original frame fixing screw of optional frame original frame optional frame left stopper left stopper ...

Page 9: ...n with fitted frame D height of inset F width of inset M depth of inset N 20mm Maximum dimension between the chimney posts E 20mm Maximum dimension between the base of the inset and the upper beam If your chimney has a wooden beam it is necessary to isolate the lower part of it if it is closer that 30cm to the hot air outlet 9 ...

Page 10: ... outer casing for a tangential fan To access this fan Unscrew the two fixing screws of the Woodbox control unit Remove the Woodbox control unit by pulling it gently down and towards you to remove the two rods attached to the back of the unit from the bottom of the shaft 10 Unscrew using an 8mm socket wrench welded hold at the back of the shaft rod attached to the control unit ...

Page 11: ...Remove the sliding plate containing the fan and the control accessories 2 screws 11 ...

Page 12: ...ive 12 fan live wire neutral wire Clixon The clixon closes the circuit when the temperature goes above 50 C The ventilator fan starts to function at the speed set by the speed drive The clixon opens the circuit at 35 C and the ventilator fan stops The switch opens the circuit stops the ventilator fan when the door is opened switch earth wire Wiring for IQ33 IQ43 IQH33 IQH43 Speed drive ...

Page 13: ...9HQWLODWHXU DEOH VLOLFRQH FP DEOH VLOLFRQH FP QWHUUXSWHXU GH SRUWH OL RQ 9DULDWHXU kEOH G DOLPHQWDWLRQ VLOLFRQH P 1 3K Y 9HQWLODWHXU DEOH VLOLFRQH FP DEOH VLOLFRQH FP QWHUUXSWHXU GH SRUWH IQ33 IQ43 IQH33 IQH43 IQH13 13 fan switch speed drive fan switch speed drive ...

Page 14: ...f an interior diameter of 100mm to make attaching the pipe easier first unscrew and remove the instrument panel 14 Flexible pipe for exterior air intake Attach the exterior air pipe to the flue outlet on the steel base Then slide the appliance on the steel base slide the teloscopic nozzles until the they touch the top of the box exterior air intake ...

Page 15: ...INSTALLATION WITHOUT EXTERIOR AIR INTAKE To allow the combustion air to come from the front of the appliance remove this part by raising two screws 15 ...

Page 16: ...er of the log is important for the heat However this classification is only an indication as the best fire wood is always the driest Wood provided at a ready to use length stored immediately in a well aired place dry quicker than those left in steres Blocks dry quicker than logs Wood chucks that are too small to be split must be drained To do this remove a portion of the bark Drying the wood will ...

Page 17: ...rding to the fuel and desired intensity WARNING the controls can be hot Always use the tool provided to adjust the controls WARNING DO NOT USE ANY GRATES ANDIONS OR ANY OTHER KIND OF SUPPLEMENTARY SUPPORT OTHER THAN THOSE SUPPLIED WITH THE APPLIANCE The appliance has two main controls The UPPER AIR FLOW control The LOWER AIR FLOW control The two controls can be used together in a way to combine th...

Page 18: ...ame time rapidly and intensively stoke the fire Such adjustments can be used to light the fire easier or to burn the soot deposits on the glass pane However the buffer settings can only be used for short periods as it can cause the appliance to overheat Controls different uses The two flaps are open to bring the maximum amount of air to the fire to make lighting it easier Closed Open Open Open woo...

Page 19: ... reach its normal performance sometimes this can take more than an hour Then adjust the flow to the desired intensity with the upper air control With practice you will quickly be able to find the position that suits you best On the grate place some paper or shavings kindling and some small logs Light the paper When the fire has started close off the lower air supply Normally it must remain in the ...

Page 20: ...ir inlet instead leave it slightly open to encourage the self cleaning of the glass pane In the event that your chimney has a strong draw it would be necessary to close the air inlet more than with a chimney with a weak draw See also the section on Setting the minimum air intake page 21 20 USING WOOD ADDING LOGS To prevent smoke fumes from entering the room while adding wood and to ensure a rapid ...

Page 21: ...he grate with the tool provided WARNING THE ASHTRAY MAY BE HOT USE HEAT RESISTANT GLOVES Open the little door and the door to have access to the ashtray Using the tool provided put it in the hole in the ashtray intended for it Pull the ashtray out from its holding Empty the ashtray and put it back in its holding Place the ashes in a metal container The container must be placed on a non flammable f...

Page 22: ...e or to completely close the minimum air intake Turn it anti clockwise to increase the minimum air intake SETTING THE MINIMUM AIR INTAKE SELF CLEANING OF THE WINDOW Your appliance is equipped with an integrated glass pane cleaning system Airwash which uses hot air to minimalize the marks on the glass pane If you use a dry fuel a large part of the tar deposited on the window will burn and disappear...

Page 23: ... of vinegar is enough to remove the majority of marks For tougher marks gently rub them with a scourer of fine steel wool lubricated with a little dish soap However be careful not to rub too hard so to avoid damaging the ceramic glass pane If manual cleaning is necessary too often you are advised to review the installation and operating method to determine if there is a better combustion possible ...

Page 24: ...e control if dropped All maintenance procedures and or the replacement of parts must be carried out by a maintenance company or a specialist recognised by NESTORMARTIN To make a warranty request for a faulty part have the part replaced and send the faulty part to a NESTOR MARTIN distributor for inspection If the fault is covered by the warranty you will not be charged for the replacement part The ...

Reviews: