OPERATING INSTRUCTIONS

V1.0   02/21

ENGLISH

READ THE OPERATING 

INSTRUCTIONS BEFORE SWITCHING 

ON THE SYSTEM!

KEEP IT IN THE IMMEDIATE VICINITY 

OF THE MACHINE AT ALL TIMES!

 

Original operating instructions

Summary of Contents for HydroPower RO S

Page 1: ...S RO20C OPERATING INSTRUCTIONS V1 0 02 21 ENGLISH READ THE OPERATING INSTRUCTIONS BEFORE SWITCHING ON THE SYSTEM KEEP IT IN THE IMMEDIATE VICINITY OF THE MACHINE AT ALL TIMES Original operating instru...

Page 2: ...s 9 1 9 Contact addresses 9 2 About HydroPower RO S 10 2 1 Using the HydroPower RO S 10 2 1 1 Intended use 10 2 1 2 Foreseeable misuse 10 2 2 Technical specifications 10 2 2 1 Operating conditions 10...

Page 3: ...tion of work 21 5 4 Switching off the HydroPower RO S 21 6 Malfunctions 22 6 1 Procedure for accidents 22 6 2 Procedure for malfunctions 22 7 Maintenance and servicing 24 7 1 General information 24 7...

Page 4: ...age mark are legally protected Any duplication processing distribution or transfer to third parties including but not limited to any kind of exploitation outside of the copyright limits require the wr...

Page 5: ...ctions for use are shown as follows To perform an action proceed as follows 1 Do this 2 Do that This is the intermediate result 3 Do that 3 You have completed the action 1 4 2 Enumerations Enumeration...

Page 6: ...classes are used DANGER Indicates a hazardous situation that can lead to serious injury or death Here you will find measures to avoid the danger CAUTION Indicates a potentially hazardous situation wh...

Page 7: ...ing of electrical voltage Warning of overpressure in containers Warning of hot surfaces Warning of suspended loads Warning of injury to the limbs 1 4 5 Mandatory signs Application tips and other usefu...

Page 8: ...ained in the handling of the HydroPower RO S have read and understood the safety instructions and safety regulations in this manual The operator is obligated to ensure that all warnings on the HydroPo...

Page 9: ...ailable to the entire staff at all times The operator must inform the personnel about the location of these operating instructions If the user manual has become illegible due to constant use the opera...

Page 10: ...nt and thus unlawful This applies in particular to the use of the HydroPower RO S for bacteria removal 2 2 Technical specifications 2 2 1 Operating conditions Ambient temperature C 5 40 Water temperat...

Page 11: ...output quantity The water flow depends on factors like water temperature hose length and hose diameter Measuring Setup Hose length each 25m 3 different hose diameters 5mm 7mm 1 2 3 different water te...

Page 12: ...stickers attached to the HydroPower RO S must always be complete and in good readable condition Renew damaged or unreadable signs Carry out cleaning and maintenance work on the HydroPower RO S only if...

Page 13: ...due to live parts Before each use perform a visual inspection of the power cable for damage If you notice any damage contact your distributor Maintenance on the electrical components of the system ma...

Page 14: ...spilled carefully clean it up immediately as there is a high risk of slipping Wear safety shoes Irritation to eyes skin and respiratory tract through membrane care Avoid any contact and swallowing of...

Page 15: ...i pre filter 9 Membrane 10 DI resin filter 11 Pump ventilation slot 12 Pump Control 13 Power cord 14 Concentrate output connection concentrate hose The manometer shows the water pressure behind the pu...

Page 16: ...dealer Complaints due to transport damage cannot be accepted without written confirmation by the dealer or with unreserved acceptance In the case of transport of the HydroPower RO S for use at height...

Page 17: ...0 ppm is considered as average water hardness Flow of water purification The water enters the HydroPower RO S via the water inlet 1 The carbon sediment combi pre filter 2 which filters out the largest...

Page 18: ...e hose at the back of the unit 2 Connect the power cord to the power supply 3 Turn on the water supply 4 Put upper switch to the position WORK 5 Turn the lower switch from OFF PURE to work with pure w...

Page 19: ...Power RO S by setting the upper switch to RO FLUSH and the lower switch to PURE Rinse out the membrane care agent for about 15 minutes 2 Switch off the HydroPower RO S turn the lower switch to OFF 3 D...

Page 20: ...o the HydroPower RO S falling are possible Place the unit on a level surface only Make sure the unit is standing securely If necessary secure the wheels with a wedge before operating the system Wear s...

Page 21: ...the lower switch to OFF You can also control the unit by the water pressure The pump control switches off automatically after some seconds in case of negative pressure To start it again press the red...

Page 22: ...ydroPower RO S to OFF to turn off the system In case of danger of injury Risk of damage to the HydroPower RO S In the event of an accident take immediate action and call the local emergency number 6 2...

Page 23: ...rheats the HydroPower RO S automatically stops 2 Switch off the system at the lower switch 3 Let the HydroPower RO S cool down 4 Start the HydroPower RO S with the lower switch e g PURE 5 If the pump...

Page 24: ...using of the pump motor can become hot during operation Allow the system to cool down sufficiently before touching components marked with this symbol Wear protective gloves ATTENTION Damage caused by...

Page 25: ...in PURE mode If this value is at or above 10 the resin filter must be replaced 7 2 2 Monthly examination Check the performance of the membrane Switch to TAP BOOST mode and observe the value in the TDS...

Page 26: ...ter cartridges left and right and dump the water Use the filter key to loosen the cartridges Store pre filter and resin filter protected from dust and dirt 3 Insert the grey suction pipe into the left...

Page 27: ...nses and rinse immediately with plenty of water Wash hands after finishing work If the display shows a value of 10 ppm or more the resin filter filter must be replaced see point 7 2 1 In addition the...

Page 28: ...port 6 Pull the membrane out and replace with a new membrane The RO membrane has an imprint indicating the flow direction the arrow must point upwards The rubber seal must always be at the bottom 7 Re...

Page 29: ...system may only be carried out by employees of Unger Germany GmbH or their authorized specialist dealers technicians CAUTION Burns due to hot surfaces possible The housing of the pump motor can becom...

Page 30: ...onment The packaging material is to be separated It consists of foam wood plastic and corrugate cardboard and is to be recycled individually according to recycling standards 8 3 Disposal of waste If t...

Page 31: ...31 HydroPower RO S Notes ENGLISH...

Page 32: ...The HydroPower RO S RO20C is compliant with the provisions of the Machinery Directive 2006 42 EC and the Directive on Electromagnetic Compatibility 2014 30 EU The protection objectives of Directive 2...