background image

1 | 

P a g e

 

 

 

                                                                                                                                                                              Revised 10.3.2018sp 

ACCESS CONTROL SOLUTIONS 

 
 

Manual Keypad Lock Programming Guide 

 

Covered lock models: E4TKSC, E5TKSB, E5TKSBS, E5TKSC, E5TKSCS 

(E5RFKSC model lock programming is NOT covered by this guide) 

 
 

Eternity 4                        Eternity 5 

 

              

                       

 

 
 

General Information: 
 

E5 v4.1 non-software lock: 

 

The non-software version of the E5 lock is programmed completely using the 

keypad on the E5 itself. A personal computer 

cannot

 be used for programming. If you 

have purchased a non-software version of the E5 and later wish to upgrade to the 
software version E5, your E5 (

except E5RFKSC

) can be retrofitted with a replacement 

printed circuit board converting it to software operation. Field retrofit is possible but not 
normally recommended. Contact your dealer or distributor for details.  

 

 

E4 / E5 v8.6 software locks: 

 

The software version of the E4 or E5 can be programmed either manually via the 

keypad on the E4 / E5 

or

 with a personal computer, DS1977 program iButton key, 

software and a Blue-dot USB reader. Most manual program modes and methods used by 
the non-software E5 are available when manually programming the software version E4 
or E5. However, an important consideration is that once you elect to program your E4 / 
E5 software lock manually instead of using a personal computer you must continue to use 
that same method. 

You cannot mix the two programming methods for a given lock.

 

Summary of Contents for Eternity 4

Page 1: ...ed with a replacement printed circuit board converting it to software operation Field retrofit is possible but not normally recommended Contact your dealer or distributor for details E4 E5 v8 6 software locks The software version of the E4 or E5 can be programmed either manually via the keypad on the E4 E5 or with a personal computer DS1977 program iButton key software and a Blue dot USB reader Mo...

Page 2: ...ed 5 times slowly when the batteries are in need of replacement Unlocking Locking indicators Non software E5 lock When in the Storehouse mode the non software version of the E5 will light the LED in the center of the iButton reader green when unlocked with the keypad or iButton It will stay green until the lock relocks when the LED will flash red twice to indicate the lock has relocked itself In g...

Page 3: ... keypad DS1977 iButtons are used to program locks only when using PC computer software to program locks It is not required to apply great physical pressure with an iButton on the reader only that the center portion of an iButton touches the center of the reader at the same time as the outer portion of the iButton rests on the outer ring of the reader This is most easily done by holding the iButton...

Page 4: ...n reader will light green After 5 seconds the lock will beep once Continue to hold the button down until the LED flashes red slowly Release the reset button immediately and press the key while the LED is still flashing The lock will beep 3 times indicating the reset and clear has been successful E4 lock The reset button is located just below the battery holder in a recessed hole Use a narrow objec...

Page 5: ...nter a programming command The LED will flash once and the keypad will briefly light but there is no other indication that programming mode has been entered either by beep or LED flashing If a valid set of programming keypad entries are not then entered within 10 seconds the E5 will automatically drop out of programming mode and return to waiting for a valid user code Master Code The master code i...

Page 6: ...r code key is or what their index number is Construction Installer Code Non software E5 lock The Construction Installer code is a manufacturer s default code for use by a lock installer or during the construction phase of a building The Construction Installer code is 0 zero then the sign This allows the installer to easily test locking and unlocking the E5 lock or to allow easy access during const...

Page 7: ...tomatically assigned an Index number in the order that they are added to the E5 beginning at 001 and incrementing by one at every new user That is 001 002 003 004 etc This index number is required if you later want to delete a user from the lock The maximum number of users is 299 You should keep track of what this index number is for each user as you enter them There is no way to obtain the index ...

Page 8: ... default mode When in Storehouse mode a valid unlock command regardless of if it is from a user key code iButton or a programmed scheduled auto unlock command the lock will unlock then automatically relock itself in 5 seconds This provides additional security in that no user can forget to relock the door the lock is on This unlock auto relock action will continue as long as the E4 E5 remains in St...

Page 9: ... a mistake pressing the correct key while entering programming simply press the key to cancel then start again from the beginning of that programming command Remember also that the lock Master code can never unlock or lock the E4 E5 it only allows programming of the lock A full list of commands and function codes is listed in this guide However for most users only a handful of commands will be req...

Page 10: ...ode 31 How to set locks internal date and time clock Function Code 88 Master code 88 yymmddhhmm year month day hour minutes How to add one user keypad code no time restriction Function Code 01 Master code 01 user code How to unlock the lock with a valid user code Enter the user code then to finish User code How to add one iButton key no time restriction Function Code 01 Master code 01 touch iButto...

Page 11: ...ode 01 touch iButton yymmddhhmm start time yymmddhhmm ending time How to add multi iButton key with time date restriction Function Code 01 Master code 01 touch iButton key 1 yymmddhhmm start yymmddhhmm end time touch iButton key 2 yymmddhhmm start yymmddhhmm end time and so on How to disable one user code or iButton key with index Function Code 02 Master code 02 index How to enable one user code o...

Page 12: ...time How to DELETE an existing user code iButton key without index number Function Code 46 Master code 46 user code or iButton key w o trailing key NOT available on non software locks with v4 1 or earlier firmware How to RE ACTIVATE an existing deactivated user code iButton key without index number Function Code 47 Master code 47 user code or iButton key w o trailing key How to DE ACTIVATE an exis...

Page 13: ... 88 3rd adding user code or iButton key in advance with 01 or use 45 for an existing user 4th program schedule days as below Day Chart This chart defines day numbers to be used for scheduling Sun Mon Tue Wed Thu Fri Sat 7 1 2 3 4 5 6 Note All examples below use 23456 as a sample master code Substitute whatever particular master code you selected during initial lock setup How to add a new user code...

Page 14: ... user code with a scheduled access time restriction Example A business wants to grant existing key code user 2222 access Monday Wednesday and Friday between 8 30am and 5 30pm remember 24 hr time Enter 23456 45 2222 135 08301730 23456 45 2222 135 0830 1730 Master Code Function code User code Mon Wed Fri Beginning time Ending time How to program an existing iButton user with a scheduled access time ...

Page 15: ... date changes at midnight each night if only very briefly Since the default lock mode is Storehouse mode the 2 minute gap in the times for Passage mode around midnight allows this to occur Practical program to automatically unlock lock on days at particular times Practical Example A business wants to have the lock automatically unlock at 8 00am and relock at 5 00pm Monday Friday on a connecting do...

Page 16: ...c unlock command for every day at a particular time Master code 64 Master code 63 unlock time Practical Example A business wants the lock to automatically unlock at 1 00am every day after lunch remember 24 hr time Enter 23456 64 enables auto unlock feature Enter 23456 63 1300 sets auto unlock time to 1 00pm Important note If the desire is for the lock to unlock at 1 00pm and stay unlocked the lock...

Page 17: ...ed light is on and three beeps Batteries low 1 Change Batteries 2 Reset the lock time and date function 88 Green light is on and two beeps but motor is not running No power to lock motor Make sure the motor wire is firmly connected to the PCB and that wire is not pinched or damaged by latch Temporary Key Code is not working Access code is expired or lock time is incorrect Check set the time date i...

Page 18: ...llow for future user deletion purposes Index numbers are automatically assigned when entered Deletion of a user does NOT shift the index numbers of other users The master code and service codes do NOT have index numbers Auto Index User Name User Code 001 002 003 004 005 006 007 008 009 010 011 012 013 014 015 016 017 018 019 020 021 022 023 024 025 026 027 028 029 030 Up to 299 users ...

Page 19: ...ability for any consequential or incidental damages resulting from the installation or operation of any merchandise purchased from us Return Exchange Policy NO RETURNS WILL BE ACCEPTED WITHOUT R M A Return Merchandise Authorization Number You can return or exchange excluding any shipping and handling charge within a period of thirty 30 days for lock merchandise and fourteen 14 days for accessories...

Page 20: ... LLC s sales and technical support associates can guide you in determining what products best solve your situations With their combined experience we re confident that our support staff have the background and talent to help you narrow your choices to the precise items that best suit your particular requirement WARRANTY DOES NOT INCLUDE TRAVEL CHARGES OR ANY OTHER COSTS INCURRED FOR FIELD ACTIONS ...