background image

 

500TT-US-W 

www.tricklestar.com 

©

 TrickleStar 

 

DAILY TIMER 500TT-US-W 

INSTRUCTIONS (ENGLISH) 

Introduction 

Thank  you  for  purchasing  this  TrickleStar

TM

  product.  This  product 

provides  enhanced  timer  control  to  reduce  wasteful  energy 
consumption  of  appliances,  which  do  not  include  timer  controls. 
This  product  is  suitable  for  a  wide  range  of  appliances  including: 
heaters,  fans,  water  pumps,  hot  water  urns,  water  coolers, 
photocopiers etc.  

Features 

The Product has the following key features: 

 

6 daily programs 

 

5 minute programming 

increments

 

 

Random ON/OFF security  (+/- 30 minutes variance from 
programmed time) 

 

Manual override button: temporary, for one program 
period only, and permanent override.  

 

Integrated battery backup – rechargeable battery 

 

 

MANUAL

 

: change power Control Socket On/Off

 

SET

 

: set time and program

 

+ (UP) 

: increment settings 
: hold for 1 sec and time will increment continuously 

- (DOWN)

 

: decrement settings 
: hold for 1 sec and time will decrement continuously

 

RESET

 

: resets product to factory defaults

 

LCD Display 

 

 

Application / Installation 

 

Plug  the  product  into  a  wall  outlet  and  plug  an  appliance  to  be 
controlled into the Control Socket.  

Factory Default Setting 

The factory default settings are: 
Time “AM 12:00”, “PROG OFF” and the Control Socket will be Off. 

Set Clock and Program Set-Up 

To set the clock: 

1.

 

Press the 

ʻ

SET

ʼ

 button. The hour digits will flash on display. 

2.

 

Use 

ʻ

+

ʼ

 or 

ʻ

-

ʻ

 button to set the hour.  

3.

 

Press the button 

ʻ

SET

ʼ

 again to set minutes. The minute digits 

will flash on display. 

4.

 

Use the 

ʻ

+

ʼ

 or 

ʻ

-

ʻ

 button set the minutes.  

 
If  you  only  want  to  set  the  clock  leave  the  display  flashing  for  15 
seconds  and  the  values  will  be  stored.  If  you  also  want  to  make 
programs then: 
 

5.

 

Press the 

ʻ

SET

ʼ

 button to set the first 

ʻ

ON

ʼ

 program time. The 

ʻ

PROG 1 ON

ʼ

 will appear on the display and flash. 

6.

 

Use the 

ʻ

+

ʼ

 or 

ʻ

-

ʻ

 button to set the ON time of the first program. 

When  pressing  the 

ʻ

+

ʼ

  or 

ʻ

-

ʻ

  button  the  time  will 

increment/decrement with 5 minute intervals. 

7.

 

Press the SET button again to set the first program OFF time. 
The 

ʻ

PROG 1 OFF

ʼ

 will appear on the display and flash. 

8.

 

Use the 

ʻ

+

ʼ

 or 

ʻ

-

ʻ

 button set the first program OFF time.  

9.

 

Pressing 

ʻ

+

ʼ

  and 

ʻ

-

ʻ

  buttons  simultaneously  will  cancel  the 

current program setting. 

10.

 

Repeat step 5-9 to set up additional ON/OFF times (up to 6). 

11.

 

When  wanted  programs  have  been  made  leave  the  display 
flashing  for  15  seconds,  the  product  will  leave  the  setting 
mode automatically programs stored. 

 

 

Random Mode 

 

Random  Mode  varies  programmed  ON/OFF  times  by  +/-  30 
minutes. 
Press  the  ‘SET’  and  ‘MANUAL’  button  simultaneously  to  switch 
between Normal Mode and Random Modes. 

 appears in the display when Random On/Off Mode is active. 

AM

OFF

Manual

Button

Set

Button

Up

Button Down

Button

Reset

+

MANUAL

SET

RESET

R

Control

Socket

LCD

Display

AM

OFF

AUTO

AM / PM

Time

ON

PM

PROG 123456

Program

Number

R

Auto Mode
Status

Random Mode

Status

Control Socket 
Status

30

7

!"

#$$

+

!"#$"%

&'(

)'&'(

:

R

R

Reviews: