background image

 

 

 
 

 

 

 

Technica Engineering GmbH

 

Leopoldstr. 236                                                
80807 München

                              

 

Email:

 

[email protected]

  

 

Web:

   www.technica-engineering.de                                                             

 

 

 

 

 

 

 

 

 

User Manual

  

Version 0.6 

May 2017 

 
 
 

 

BroadR-Reach (100Base-T1) 

– Standard Ethernet

 

 BR_SPY_mini 

Summary of Contents for BR_SPY_mini

Page 1: ...nica Engineering GmbH Leopoldstr 236 80807 M nchen Email info technica engineering de Web www technica engineering de User Manual Version 0 6 May 2017 BroadR Reach 100Base T1 Standard Ethernet BR_SPY_...

Page 2: ...Page 2 of 23...

Page 3: ...nnectors 8 4 Status LEDs and Pushbutton 9 5 Configuration 10 6 Use Cases 11 6 1 Dual Media Converter Mode 0 0 11 6 2 Spy Mode Without Wrapper 0 1 12 6 3 Spy Mode With Wrapper 1 0 13 6 3 1 BRSPY mini L...

Page 4: ...duct to be programmed properly at Technica Engi neering side before delivery Features 4 Ports BroadR Reach 100Base T1 Ethernet 100 MBit s Fullduplex on a single un shielded twisted pair 2 Ports Gigabi...

Page 5: ...ions Do not apply power to a damaged device Do not open the device Otherwise warranty will be lost This device is designed for engineering purpose only Special care has to be taken for operation Do no...

Page 6: ...Page 6 of 23 3 Pinning The pinning of the ECU connectors is listed on the label on top of the device detail infor mation see below...

Page 7: ...mber 965778 1 alternatively Part Number 962108 2 Tyco crimp contact Part Number 928999 1 Note You can use the official Tyco tool for these crimp contacts A cheap variant is the crimp tool for PSK cont...

Page 8: ...utput 4 8 Digital Trigger Input Output 5 9 Digital Trigger Input Output 6 Table 2 Pinning information Sub D connector Digital Trigger Output Digital Trigger Output Voltage is 3 3 Volt Level with a 4 7...

Page 9: ...flat on the table Switch OFF Switch set to down position when the device stands flat on the table The 4 BR Link LEDs 1A to 2B monitor the link status of the ports BR1A to BR2B The LEDs are lit when th...

Page 10: ...to 4 Use Case Selection DIP Switch 3 OFF DIP Switch 4 OFF Dual Media Converter Mode DIP Switch 3 OFF DIP Switch 4 ON SPY Mode Without Wrapper DIP Switch 3 ON DIP Switch 4 OFF SPY Mode With Wrapper DIP...

Page 11: ...F The BR_SPY_mini will act like two completely independent Media Converters from BroadR Reach 100Base T1 to Fast Ethernet 100Mbps in Full Duplex Mode The two data streams of the two Media Converters a...

Page 12: ...PC is not able to send data The RJ45 Ports are output only In this case no header is added in the sent Ethernet frame and the received frames on the BroadR Reach 100Base T1 ports are forwarded directl...

Page 13: ...he bus port the data was originally sent on Timestamps are in 0 04 s resolution and syn chronous to all connected BR 100Base T1 lines With this feature the user can record the exact time when the firs...

Page 14: ...0x00 BR 1B 0x01 BR 2A 0x02 BR 2B 0x03 Table 4 values of Port field within the BR_SPY_mini Header The following image shows an example of a BroadR Reach 100Base T1 payload frame encapsulated in a BR_S...

Page 15: ...se that the program is running on PC 2 Download the ZIP file that contains all the LUA files through this website http www technica engineering de wp content uploads 2017 01 BroadR Reach SPY Mini Wire...

Page 16: ...5 To copy or move the LUA files to the specified Wireshark plugins folder Administrator rights will be needed In that case the following window should appear Press Continue to proceed with the copy 6...

Page 17: ...es DIP Switch 6 This switch selects the Packets Size When it is OFF the size of the frame will be 64 bytes and when it is ON the size will be 1500 bytes The sizes don t include the preamble and CRC DI...

Page 18: ...Stream ID field This Stream ID field shows the port number where the frame is being sent Stream ID Value Function 0 BR1A 1 BR1B 2 BR2A 3 BR2B 4 GB1 5 GB2 Table 5 Stream ID field on Frame Generator Mo...

Page 19: ...tinuous Counter fields are checked and the result is reported each second in a Status Frame This frame is transmitted on GB2 with the following format In this port the StreamID 5 and the GB1 works as...

Page 20: ...n was enabled It is disabled while errors occur SequenceErrorCounter 2 Counter for detected sequence errors after checker locked This counter is not reset IgnoredFrameCounter 2 Counter for frames that...

Page 21: ...is detected and when a frame is being transmitted on one of the Gigabit ports as is shown in the following table Pin Function 1 BR1A Data Valid 2 BR1B Data Valid 3 Signal Ground Reference 4 Signal Gr...

Page 22: ...eCase When using automotive AVB profile the time synchronization is not influ enced by the SPY There is no special handling of AVB frames as this is not necessary Q The BR Link LED is lit but I have n...

Page 23: ...please feel free to contact us Technica Engineering GmbH Leopoldstr 236 80807 M nchen Germany Technical support support technica engineering de General information iInfo technica engineering de Most...