PURE SINE WAVE HOME UPS 

USER'S MANUAL (IFU)

Before connecting, operating, or adjusting this unit, please read this instruction booklet carefully .

Salient features 

GLOBAL CERTIFICATIONS:

GLOBAL CERTIFICATIONS:

GOVERNMENT OF INDIA

GOVERNMENT OF INDIA

MINISTRY OF SCIENCE & TECHNOLOGY

MINISTRY OF SCIENCE & TECHNOLOGY

R&D

R&D

Recognised 

Recognised 

ISO 14001:2004

7

Pure Sine wave output to run all 
the appliances

7

Fuzzy  logic  control-  a  unique  & 
advanced technology 

7

Smart Overload Sense and Short 
Circuit Protection

7

Automatic Low Battery Cutout

7

Smart  SMPS  based  fast  battery 
charger  with  automatic  power 
factor correction 

7

Peak Power output 300%

7

User-friendly Graphic display

7

Future Expandability possible

Customer Care : +91 124 4170561-566

Customer Care : +91 124 4170561-566

Summary of Contents for FALCON

Page 1: ...OF SCIENCE TECHNOLOGY R D R D Recognised Recognised ISO 14001 2004 7 Pure Sine wave output to run all the appliances 7 Fuzzy logic control a unique advanced technology 7 Smart Overload Sense and Short Circuit Protection 7 Automatic Low Battery Cutout 7 Smart SMPS based fast battery charger with automatic power factor correction 7 Peak Power output 300 7 User friendly Graphic display 7 Future Expan...

Page 2: ...ion We value your suggestions and comments Su Kam is committed to continual product improvement and the best way to accomplish this task is by listening to our valued customers This commitment gets strengthened every time you buy a Su Kam product We appreciate the support you have shown us through the purchase of our product Please read this manual to become familiar with its features and various ...

Page 3: ...E HOME UPS REV 08 06 07 Contents CONTENT KNOWINGYOUR HOME UPS A FRONT PANEL 1 2 B BACK PANEL 3 4 IMPORTANT SAFETY INSTRUCTIONS 4 5 6 SPECIAL NOTICES 6 TROUBLE SHOOTING 7 TECHNICAL SPECIFICATIONS 8 9 WARRANTY CARD 10 ...

Page 4: ...able 2 INV ON This graphical symbol is lit when the incoming mains is not available and the output is from Home UPS 3 BATT CHARGING CHARGED This graphical symbol shows that the mains line is coming and side by side the charging of batteries is also taking place This graphical symbol glows intermittently during charging and glows continuously when battery is charged 4 FUSE BLOWN Mains fuse blows of...

Page 5: ...se of overload and 4 attempts in case of short circuit to turn on again if the overload or short circuit continues even after these attempts it turns off permanently and will turn on only after ON OFF power active switch is turned OFF and then turned ON In the event of unsuccessful attempts it automatically shuts down During overload or short circuit graphical symbol lights up and the buzzer gives...

Page 6: ... is connected to earth Green Wire After this the output is connected through the output socket at the rear of the Home UPS or input terminal block home UPS the Home UPS REARVIEW BACK PANEL Note REV 08 06 07 1 Position the Toggle Switch 4 at the rear panel to Narrow Window UPS mode if you want to run PC load otherwise always place the switch to WideWindow INV mode 2 Position theToggle switch 5 to H...

Page 7: ...riorsonly 3 Do not disassemble the Home UPS take it to a Su Kam Engineering Service Centre when service or repair is required Opening by unqualified personnelentails electricshockorfirehazard 4 Toreduceriskofelectricshock disconnectallwiringbeforecleaning Back panel view 1400VA REV 08 06 07 OUTPUT OUTPUT INV RED BLACK UPS NC HC 2 6 _ 3 4 5 Input N E L 1 1 Input terminal block Mains Input for Home ...

Page 8: ...EADACID BATTERY MAY BE DANGEROUS BATTERIES GENERATE EXPLOSIVE GASES DURING NORMAL OPERATION ProvideventilationtooutdoorsfromtheBatterycompartment Thebatteryenclosuresshouldbedesignedtopreventaccumulationand concentrationofhydrogengasin pockets atthetopofthecompartment Ventthebatterycompartmentfromthe highestpoint Aslopedlidcanalsobe used to direct the flow to the vent opening location To reduce th...

Page 9: ...ystem Special Notices PURE SINE WAVE HOME UPS IMPORTANTPRECAUTIONS The output side of the AC wiring should never be connected to a generator or incoming utility power This condition is far worse than a short circuit If the unit survives this condition it will shut down until correction is made Note Never disconnect the battery cables while the is delivering power or battery charger is operating Th...

Page 10: ...n Reduce the load and replace the glass fuse of specified rating given at the rear side of the Home UPS Low Battery Check condition of batteries recharge Loose or corroded battery connections LooseAC output connections Measuring with the wrong voltmeter Output of Home UPS is wired back to its own input Check the properAC input and output wiring Weak batteries or battery cables too long Refer to ca...

Page 11: ...Lower Voltage Limit Recommended Battery Capacity Number of Batteries 1 1 1 2 Charging Float Volatge 9 1 0 Amp 13 1 0 Amp for HC mode 0 13 9V 0 2V per battery 13 6V 0 2V per battery 10 V 0 0 2V per battery 135AH 180AH VOLTAGE LIMITS WIDE WINDOW INV MODE Mains A C Low Cut 1 5 0 5V 1 0 2 5V 2 5 8 5V 275 5V Mains A C Low Cut Recovery Mains A C High Cut Mains A C High Cut Recovery OUTPUT PARAMETER 50 0...

Page 12: ...2V 800VA 12V 800VA 12V 1400VA 24V 272X275X122 280X270X123 392X310X170 400X296X170 10 2 Kg 16 9 Kg Dimension W X D X H in mm Weight Kg Microcontroller based state of the art technology using MOSFETs Fuzzy Logic Control Technology TECHNOLOGY Storage Temp 0 50 C 0 40 C 0 90 Non condensing Operating Temp Humidity ENVIRONMENT MODEL CAPACITY 9 3Kg 272X275X122 300X300X130 10 40 Kg ...

Page 13: ...the purchaser The problem of fuse blown will not be included in the warranty of the product The services given for the same will be paid service The company is in no way are will be held liable for any loss or injury or damage caused to life or property or death and disability caused to any form of life for any reason whatsoever The warranty will not apply if the original seals are found broken or...

Page 14: ...nter su kam com DELHI 940 2nd Floor Synagogue Street Near Railway Reservation Centre Camp Pune 1 Maharashtra Tel 020 32303900 30523788 09975496268 Email pune su kam com PUNE 74 D Plot No 1 Park Road 3 Ashok Nagar Ranchi 834002 Jharkhand Tel 0651 3203277 09934015338 Email ranchi su kam com RANCHI 13 7 Site No 3 Meerut Road Industrial Area 3 Near Uttam Toyota Ghaziabad 201001 Uttar Pradesh Tel 91 12...