Pi-UpTime UPS 2.0  

UPS for Raspberry Pi-4 using Li-
Ion or Li-Phosphate batteries 

Pi-UpTime UPS 2.0 is a new 
and improved version of the 
Pi-UpTime UPS. Pi-UpTime 
UPS 2.0 is designed to work 
with the Pi-4 or other SBC

’s

such as Odroid, Asus, Arduino 
etc. Power is supplied via the 
40-pin header or via the 
micro-USB out port. Powering 
the Pi and charging the 
battery is done on the Pi-
UpTime UPS 2.0 via a USB-C 
or a micro-USB connector. 
Only one connector can be 
used at any time for power. 
The micro-USB connector is provided for backward compatibility.  The Pi-UpTime 2.0 
has the same dimensions as a Pi-4 (or Pi2, Pi3, etc.) and can be mounted securely on 
a Raspberry Pi using 20 mm spacers for a compact, mechanically secure connection. 

An on-board 12-bit ADC monitors Vin, Vout and battery Voltage for accurate 
information on operating conditions. Temperature sensor below the battery provides 
accurate battery temperature information. Battery charging takes place between 0

o

and 50

o

C. 

No GPIO connections or GPIO monitoring is needed.

 ADC provides 

information via the I

2

C. Up to three different I

2

C address can be selected via jumpers 

J11, J12 to avoid conflict with other I

2

C devices. Sample python code is provided for 

monitoring system parameters and shutdown the system when power fails, and 
battery is low. Sample code can be downloaded from 

www.alchemy-power.com

  

External connections, via solder points, are available for I

2

C, Vin, Battery and Vout. 

The connections can be accessed via 2.54mm (100 mil) terminal blocks or by direct 
soldering. Terminal blocks are not included. External sensors or external controllers 
such as an Arduino controllers or other embedded micro-controllers can tie into the 
I

2

C connection.  

Key Features: 

 

Provides UPS 
functionality for 
Raspberry Pi. 

 

Includes USB-C and a 
micro-USB connector 
for Power In. 

 

Use 18650 size Li-
FePO4 or Li-Ion/Li-
Polymer battery 

 

jumper selectable. 
Batteries not included.  

 

Attach external battery 
to solder points 
provided using JST, 
term-block or solder. 

 

No reboot when power 
fails. UPS power is 
provided seamlessly. 

 

Ideal diode power OR 

 

minimal heating or 
power loss.  

 

External connection 
points for I

2

C, input V, 

output V and battery. 

 

Monitor Input, Output, 
Battery Voltage and 
temperature via ADC 
using I

2

C. Up to three 

I

2

C addresses. 3mV 

sensitivity. Sample 
Python code provided.  

 

Add power on/off 
switch to turn off all 
power to Pi. All power, 
including UPS power, is 
off when switch is off. 
Battery charging 
continues. 

 

UPS Power - 5V, 2.5A 
and USB. 3.3V, 0.7A 

Pi-Z-UpTime UPS 2.0. See pictures enclosed in data 
sheet for additional information. 

New 

Summary of Contents for Pi-UpTime UPS 2.0

Page 1: ...void conflict with other I2 C devices Sample python code is provided for monitoring system parameters and shutdown the system when power fails and battery is low Sample code can be downloaded from www alchemy power com External connections via solder points are available for I2 C Vin Battery and Vout The connections can be accessed via 2 54mm 100 mil terminal blocks or by direct soldering Terminal...

Page 2: ...ting on jumper J4 Install one or two 18650 batteries not included Please ensure the batteries are installed with the proper polarity Reversing the polarity will damage the electronics Includes full Battery Management System BMS Charges the battery when power is available using CC CV charging methods Depleted batteries are charged initially at a low current allowing batteries to recover On board AD...

Page 3: ...er source of power o Yellow Power supply input V is below 4 8V and battery may not charge At this Voltage the Raspbian OS also shows a lightining bolt as well Sample Python code to monitor system is available Download from Alchemy Power Inc website or at www alchemypower com downloads Output Voltage UPS generates regulated 5 0V 2 across full load range When the Power is available via the Power on ...

Page 4: ...stry battery not supplied Li Ion 18650 battery Li Ion Li Polymer OR Lithium Phosphate jumper selectable Battery Holder On top 2x18650 size On top like previous version OR external via terminal block Access to Vin Vout Battery No Yes via terminal blocks and in software via the on board ADC Input V Max 5 5V via micro USB only Max 5 5V via micro USB in OR via terminal blocks not included Output V 4 6...

Page 5: ...t CC CV charging Battery charge level maintained over time CC CV charging Battery charge level maintained over time Safety CCCV charging temperature monitoring CCCV charging temperature monitoring PTZ fuse to prevent battery loop current System current limit of 2 5A LED s Many Green Battery is charging Blue UPS is on Yellow Input V is below 4 8V Red Fault Power in Via micro USB Via USB C or micro ...

Page 6: ... white text Black with white text Planned use future Legacy Not recommended for new designs Recommended for new designs Other Provides 3 3V 0 8A max UPS protected by PTZ fuse Provides 3 3V 0 8A max UPS protected by PTZ fuse I2 C NA Onboard ADC uses I2 C I2 C can be extended to external sensors via terminal block UPC code 691852747139 708088352584 ...

Page 7: ...ut Battery V and temperature monitored via on board 12 bit ADC Shutdown routine Sample Python code provided Sample Python code provided Sample Python code provided Adjust battery level to trigger shutdown No Yes controlled in software Yes controlled in software LEDs Charging charge complete Charging Charging UPS on when Input V 4 8V brown out Charge current 1A 0 5A 1 2A Models supported Any up to ...

Page 8: ...re monitoring Battery charging is disabled when it s too hot or too cold PTC fuse protection between batteries to prevent current loops Max charge and use current monitoring current limits Current limit Only for charge current Only for charge current Charge current and max current monitoring Board Color Green Black Black Board dimensions 35mm x 28mm x 12mm 4 mounting holes Can be mounted on a Pi Z...

Page 9: ... 2019 Alchemy Power Inc All Rights Reserved All information subject to change without notice Picture Gallery Pi Z UpTime UPS 2 0 Pi UpTime UPS 2 0 with the functions ...

Page 10: ... 2019 Alchemy Power Inc All Rights Reserved All information subject to change without notice CAD outline with functions Pi UpTime UPS 2 0 with On Off Switch and charging LED on ...

Page 11: ...Rights Reserved All information subject to change without notice LED jumper is off turning off all LED s Shows mounted on a Pi 4 model PI UpTime UPS 2 0 with Li PO4 Lithium Phosphate batteries connected to disk drive and USB disk ...

Page 12: ... 2019 Alchemy Power Inc All Rights Reserved All information subject to change without notice Packaging Insert card recommends install steps ...

Page 13: ...xternal battery via Batt and Ground connect points Either use external battery or 18650 battery in the battery holder Using both external batteries and batteries in the holder can cause current loops and damage the circuitry Internal or external battery can be Li Polymer Li Ion or Pi PO4 Battery chemistry selection via Jumper J4 Li Ion and Li Poly use the same setting Make sure battery chemistry i...

Page 14: ...ompliant Recommend Onshore Technology Inc OSTVN02A150 Terminal blocks Other manufacturers also provide equivalent terminal blocks which can also be used Terminal Blocks 3 3V UPS Soldered 3 5mm spacing Power on off Switch Reset Turn power off by pulling out Power On Off jumper shunt Turn power back on by inserting jumper shunt Power shunt remove reinsert sequence causes a power reset and a reboot E...

Page 15: ... to the respective trade mark holders Please refer to the respective organizations for Trade Mark right of use and other information Alchemy Power Inc 2098 Walsh Avenue Suite A Santa Clara CA 95050 2544 Phone 650 823 2316 Email sales alchemypower com www alchemypower com ...

Reviews: