Page 1: ... Installation Manual 操作 安装说明 Petunjuk Pemakaian Pemasangan Hoạt động Hướng dẫn lắp đặt คู มือการติดตั ง การใช งาน Slim Line Hood RH S259 SSV T RH S259 PBV T RH S259 SSR T RH S259 PBR T Rinnai Corporation English ...

Page 2: ...Page 1 7 English Version 2015 06 TABLE OF CONTENTS ...

Page 3: ... allow young children to play with or operate the appliance Supervise its use by the elderly or infirm Installation and repair should be attempted by qualified technical personnel only It is dangerous to modify any part of this appliance Tampering with electrical connections or mechanical parts can cause operation faults and may put the user at risk Never leave high naked flames under the extracto...

Page 4: ...o responsibility for complaints attributed to the design and layout of the pipe work Do not flambé or grill with an open flame directly under the extractor hood Flames could be drawn up into the hood by the suction and the grease filters may catch fire Monitor cooking continuously as overheated oil increases the risk of self ignition Do not operate the extractor hood without a grease filter It is ...

Page 5: ...t to effect any technological improvement or modification without prior notice SPECIFICATIONS COMPONENTS Fig 2 English A B C D E F G H I REF QTY PRODUCT COMPONENTS A B C D E F G H I 1 1 1 1 1 1 1 1 1 Body Air Outlet Recirculating assembly Duct assembly Lamp Bottom Plate Aluminium Charcoal Filter Rectifier Panel Oil cup Aluminium Charcoal Filter applies to ventilation models For recirculation model...

Page 6: ...on INSTALLATION English Installation 2nd Method According to the diagram below A Remove bottom plate rectifier panel and oil collector as shown B Fix the hood on the cupboard from the inside C Fix the bottom plate rectifier panel and oil collector back D Finished installation Ducted vs Recirculating Mode Ducted Mode In ducted mode cooking fumes are vented outdoors In this mode only aluminum filter...

Page 7: ...ndicator is to remind you to change to new filters To cancel the reminder press and hold the ON OFF button for 4 seconds and the timing display will resume LIGHT Press to turn the light on off Press ON OFF and press to increase motor power press descrease motor power The motor has 4 speed settings OPERATION ON OFF DISPLAY TIMER LIGHT English Delay Timer 3 Minutes When the hood is switched on press...

Page 8: ... power supply cord before carrying out any cleaning or maintenance activities It is important to clean and or replace the filters at appropriate intervals as grease deposits build up increases the risk of fire Do not operate the extractor hood without grease filter You are strongly recommended to follow these safety instructions The manufacturer will not be held liable for any damages to the appli...

Page 9: ...ation mode Motor is running but no airflow Poor exhaust Please contact Rinnai Customer Care Service Whirring sound Foreign object may be in contact with fan blade Please contact Rinnai Customer Care Service Lights are not working Lamps are burnt out Replace the damaged lamps Lamps are loose Tighten the lamps TROUBLESHOOT If problem persists after the above checks please contact Rinnai Customer Car...

Page 10: ...89 Fax 传真 853 2822 2733 URL 网址 www rinnai com hk mo Thailand ประเทศไทย Rinnai Thailand Co Ltd Lucky Flame Co Ltd 61 1 Soi Kingkaew 9 Kingkaew Rd Racha Thewa Bangphli Samutprakarn 10540 Thailand บริษัท รินไน ประเทศไทย จำกัด เลขที 61 1 ซอยกิ งแก ว 9 ถนนกิ งแก ว ตำบลรำชำเทวะ อำเภอบำงพลี จังหวัดสมุทรปรำกำร ประเทศไทย 10540 Tel 66 2 3124330 40 Email lucky02 luckyflame co th URL www luckyflame co th Mala...