WARNING:  
If the information in these instructions are not followed exactly, 
a  fi re or explosion may result causing property damage, 
personal injury or loss of life. 

FOR YOUR SAFETY
Do not store or use gasoline or other fl ammable vapors and 
liquids in the vicinity of this or any other appliance.

Installation and service must be performed by a qualifi ed 
installer, service agency or the gas supplier.

FOR YOUR SAFETY
What to do if you smell gas:
  Do not try to light any appliance
  Do not touch any electrical switch: 

do not use any phone in your 
building.

  Immediately call your gas supplier 

from a neighbour's phone. Follow 
the gas supplier's instructions.

  If you cannot reach your gas 

supplier, call the fi re department.  

FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.  6988 Venture St., Delta, BC  Canada, V4G 1H4

918-769c

Regency Bellavista

 

B36XT

 

Gas Fireplace
Gas Fireplace

05/05/14

Owners & 

Installation Manual

www.regency-fi re.com

Tested by:

Installer: Please complete the details on the back cover 

and leave this manual with the homeowner.

Homeowner: Please keep these instructions for future reference.

MODEL: B36XT  

Medium DV Gas Fireplace

Bellavista B36XT Video

Summary of Contents for B36XT Bellavista

Page 1: ... Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department FPI FIREPLACE PRODUCTS INTERNATIONAL LTD 6988 Venture St Delta BC Canada V4G 1H4 918 769c Regency Bellavista B36XT Gas Fireplace Gas Fireplace 05 05 14 Owners Insta...

Page 2: ...fireplace at the flick of a switch The Bellavista B36XT has been approved by Warnock Hersey Intertek for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many features of your Regency Fireplace Bellavista B36XT Bell...

Page 3: ...nstallation instructions and local codes if any In the absence of local codes follow the current National Fuel Gas Code ANSI Z223 1 and the current National Electrical Code ANSI NFPA 70 in the U S A and the current CAN CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22 1 in Canada This appliance comes equipped with a dedicated 8 Ground Lug for attachment of the ground ...

Page 4: ...ng arrangements 33 With Co linear Flex System 33 Vertical Terminations 34 Co linear Flex System Into Masonry Fireplaces 34 Unit Installation with Horizontal Termination 35 4 x 6 5 8 or 5 x 8 venting 35 Unit Installation with Horizontal Termination 36 5 x 8 venting unit installation w Vertical Termination 37 4 x 6 5 8 venting 37 Gas Line Installation 37 Pilot Adjustment 38 High Elevation 38 Gas Pip...

Page 5: ...alorifique Calorifique é é é é é é é 5 0 1 25kPa 3 5 0 87kPa 1 6 0 40kPa 35 DMS 0 4500 ft pi 0 1372m WC C E WC C E WC C E 21 500 Btu h 6 3kW 31 000 Btu h 9 09kW Pression d allimentation minimum Pression à la tubulure d chappement lev e Pression à la tubulure d chappement basse Grandeur de l injecteur D bit minimum selon D bit maximum selon l altitude Calorifique Calorifique é é é é é é 11 2 74kPa ...

Page 6: ...ctly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspect...

Page 7: ...IMENSIONS 40 5 16 1024mm 21 533mm 33 838mm 36 914mm 35 1 4 895mm 30 3 8 762mm 1 25 4mm 41 5 16 1049mm 35 1 4 895mm 26 1 2 673mm 20 1 4 514mm 17 5 16 440mm 20 5 16 516mm 33 1 16 840mm C L 11 7 16 291mm 38 1 16 967mm 39 1 2 1003mm 35 1 2 902mm Full Screen Doors ...

Page 8: ...when installed must be electrically grounded in accordance with local codes orintheabsenceoflocalcodeswiththe current National Electrical Code ANSI NFPA 70 or CSA C22 1 Canadian Electrical Code 3 See general construction and assembly instructions The appliance and vent should be enclosed 4 This appliance must be connected to the specified vent and termination cap to the outside of the building env...

Page 9: ...g FinishingRequirements Refer to Framing Finishing section e VentingRequirements Referto Venting section 2 Assemble Top Standoffs and Top Facing Support and Side Nailing Strips Refer to Unit AssemblyPriortoInstallation Section NOTE Must be done before installing unit into place 3 Install vent Refer to Venting sections 4 Make gas connections Test the pilot Must beasperdiagram Referto PilotAdjustmen...

Page 10: ...lated fires is failure to maintain required clearances air space to combustible materials It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions B36XT Clearance Requirements Minimum Vent Clearances to Combustibles Clearance Dimension Measured From A Mantel Height min 13 330mm Top of Fireplace Opening B Sidewall 12 304mm one side...

Page 11: ... from top of front facing are shown in the diagram on the right Note A non combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non combustible board Mantel Clearances B36XT A B C D From Top of Fireplace Opening 32 813mm 21 533mm 17 1 2 445mm 13 330mm Combustible Mantel Clearances 2 0 12 6 4 8 10 0 Top of Fireplace Opening 12 1 7 A B C Non comb...

Page 12: ...1 4 1073mm Non combustible Min 3 76mm 42 1067mm Non combustible 36 914mm Non combustible Material Non combustible Header steel stud on edge 40 5 8 1032mm Framing 35 1 4 895mm 12 Side Wall Measured from side of Fireplace Opening 6 5 3 5 Mantel leg Mantel leg Allowable mantel leg projection 3 1 1 2 See framing dimensions on next page ...

Page 13: ...562mm other approved caps Q Top Vent Corner Facing Wall Width 68 3 4 1746mm Q Rear Vent Corner Facing Wall Width 75 1905mm AstroCapXL 87 2209mm other approved caps R Rear Vent Framed Chase Ceiling Rear 41 12 1054mm R Top Vent 5 x 8 Framed Chase Ceiling Top 50 1 2 1283mm R Top Vent 4 x 6 5 8 Framed Chase Ceiling Top 54 1 2 1384mm S Rear Vent Vent Centerline Height Rear 26 1 2 673mm S Top Vent 5 x 8...

Page 14: ...p of the firebox opening Full Screen Doors Only If finishing with any material thicker than 1 1 4 a 3 4 gap must be maintained between the full screen doors and the finishing material This gap is necessary to facilitate the installation and removal of the full screen doors Note All non combustible facing material should butt up cleanly to the flanges around the firebox opening Rough edges will be ...

Page 15: ...ons A B or C depending on your facing depth Screw Facing Material Position Depth A 1 2 13mm B 7 8 22mm C 1 1 4 32mm For C screw position the top facing support is reversed Top Facing Support A B C Screw holes for Top Facing Support Top Facing Support is reversed for C hole position A B C C Screw Position For a facing material depth of 1 1 4 32mm the top facing support must be reversed Top Facing S...

Page 16: ... Insulation Plate Cover 1 Insulation Filling Exhaust Assembly w gasket Intake Cover Plate w gasket Insulation cover plate Insulation filling Intake Collar Assembly Intake Collar Assembly w gasket w gasket 2 From inside the firebox remove the top heat deflector by removing 2 screws Heat Deflector Diagram 2 1 Remove the door assembly by releasing the adjustable latches and lifting up off the door fr...

Page 17: ...ws Diagram 9 Ensure all screws are tight but do not over tighten All 8 screws must be used Diagram 8 Diagram 9 10 From the outside rear of the firebox install the intake cover plate with 4 1 4 x 1 2 screws Ensure all screws are tight but do not over tighten All 4 screws must be used 11 Set vent restrictor accordingly see next page 12 From inside the firebox re install the baffle plate and heat def...

Page 18: ...f a vent restrictor setting is required Note The vent restrictor does not apply to rear vent applications 4 Align the vent restrictor plate to the required vent restrictor position as per the diagrams shown 5 Once the vent restrictor plate is in the required position secure with 2 1 4 x 1 2 screws Ensure all screws are tight but do not over tighten See diagram 2 VENTING INTRODUCTION The B36XT uses...

Page 19: ...xtended above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 12 30cm 9 23cm L Clearance to a mechanical air supply inlet 3 91cm above if within 10 3m horizontally 72 1 8m 36 90cm b M Clearance above paved sidewalk or a paved driveway located on publ...

Page 20: ...A N A N A N A Adjustable Length 7 Black N A N A 4D7AB N A N A N A Extension Pipe 8 1 2 Galvanized 46DVA 08A N A N A N A N A N A Extension Pipe 8 1 2 Black 46DVA 08AB N A N A N A N A N A Adjustable Length 12 Galvanized N A N A 4D12A N A SV4LA12 N A Adjustable Length 12 Black N A N A 4D12A N A SV4LBA12 N A Extension Pipe 16 Galvanized 46DVA 16A N A N A N A N A N A Extension Pipe 16 Black 46DVA 16AB ...

Page 21: ...n 36 N A N A N A N A N A TM 4ST36 Basic Horizontal Termination Kit A Disc 4DT HKA 4DHTK2 4DHTKA SV SHK N A Horizontal Termination Kit B 46DVA KHA Changed Components 4DT HKB 4DHTK1 4DHTKB SV HK N A Vertical Termination Kit Disc 4DT VKC 4DHTK 4DHTK SV FK N A FPI 946 506 P Vent Guard Optional for AstroCap 946 205 Vinyl Siding Shield for Riser Vent Terminal 510 994 Rigid Pipe Adaptor Must use with all...

Page 22: ... 58DVA CS 5DT CSS 5DRS TE 5DE45B Wall Support Band 58DVA WS 5DT WS B 5DWS N A Offset Support 58DVA ES N A from FPI 5DT OS N A N A Wall Thimble Black 58DVA WT 5DT WT 5DWT TE 5DE90 Wall Thimble Support Ceiling Support 58DVA DC N A from FPI N A N A TE 5DE90B Firestop Spacer 58DVA FS 5DT FS 5DFS N A Trim Plate Black 58DAV WFS 5DT TP 5DCP N A Description Simpson Direct Vent Pro Selkirk Direct Temp Meta...

Page 23: ...impson Direct Vent Vent Guard Optional 946 623 P AstroCap XL Horizontal Cap 770 994 Rigid Pipe Adaptor Must use with all rigid piping 946 506 P Vent Guard Optional 946 606 Starter collar reducer 5 x 8 to 4 x 6 5 8 946 625 Vinyl Siding Standoff AstroCap XL Note When using Metal Fab Sure Seal Rigid Piping please note that the Adaptor 4DDA must be used in conjunction with FPI Rigid Pipe Adaptor 510 9...

Page 24: ...ions with a maximum continuous vent maximum horizontal length of 3ft 0 9m Note Must use optional rigid pipe adaptor Part 770 994 when using Rigid Pipe vent systems Maintain clearance to combustibles Horizontal vent must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall 2 0 12 6 4 8 10 2 0 6 4 8 Vertical Height Feet Rigid 44 1 4 1 1m Horizontal...

Page 25: ...f 42 1 3 to centerline No other application is approved 1 8 dia flexible liner 4 ft length 2 5 dia flexible liner 4 ft length 3 spring spacers 4 4 thimble 5 AstroCapXL termination cap 1 6 screws 12 7 tube of Mill Pac 1 8 plated screws 8 9 screws 8 x 1 1 2 Drill Point Stainless Steel 4 10 vinyl siding standoff Notes 1 Liner sections should be continuous without any joints or seams 2 Only Flex pipe ...

Page 26: ...th Horizontal Termination Cap Wall Thimble Vinyl Siding Standoff Optional Horizontal Termination A Top Vent No Vertical Rise When venting with a 90 elbow directly off the unit must use 5 X 8 AstroCapXL Flex vent or approved Rigid Vent System Max 3 ft horizontal run B Rear Vent w Horizontal Termination Can only use 5 x 8 venting Max 3ft horizontal run B A HORIZONTAL TERMINATIONS RIGID PIPE 5 X 8 ...

Page 27: ...3 P 1 Rigid Pipe Adaptor 770 994 1 Vinyl Siding Standoff Optional 946 625 1 Wall Thimble 58DVA WT 1 6 galvanized rigid pipe 58DVA 06 1 8 1 2 galvanized pipe extension 58DVA 08A 1 45º galvanized elbow 58DVA E45 1 90 ml MillPac 948 128 26 1 2 673mm Placement of the unit into the corner Back top corner of unit to wall 4 Inside corner out along the wall 53 Across the face of the unit wall to wall 75 I...

Page 28: ...UCER PART 946 606 770 994 RIGID PIPE ADAPTOR The diagram shows all allowable combinations of vertical runs with horizontal terminations using one 90o two 45o elbows equal one 90o elbow Maintainclearancestocombustiblesaslistedin Clearances section Horizontal vent must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall A wall thimble is mandatory...

Page 29: ...ired it must be used with vinyl siding measure to outside surface of wall without siding and add 2 inches Note The 4 x 6 5 8 Regency Flex Kits 946 515 946 516 are not approved for use with this fireplace Only rigid pipe may be used when 4 x 6 5 8 is used The FPI AstroCapTM and FPI Riser Vent terminal are certified for installations using FPI venting systems as well as Simpson Dura Vent Direct Vent...

Page 30: ...ducer 946 606 and rigid pipe adaptor 770 994 No Vent Restrictor Installed HORIZONTAL TERMINATIONS THREE 3 90O ELBOWS RIGID PIPE 4 X 6 5 8 V1 H1 H V Lengths do not include elbow indicated Must use reducer 946 606 and rigid pipe adaptor 770 994 Option V H V V1 H H1 A 0 Min 1 Max 1 Min 2 Max B 1 Min 2 Max 3 Min 3 Max C 2 Min 2 Max 5 Min 4 Max D 3 Min 2 Max 7 Min 5 Max E 4 Min 3 Max 9 Min 6 Max F 5 Mi...

Page 31: ...each floor level and whenever passing through a wall Maintain clearances to combustibles as listed in the Clearances section Refer to the Vent Restrictor Position section for details on how to change the vent restrictor from the factory setting to 2 14 opening 1 5 8 opening and to 1 1 16 opening Note Must use optional flue adapter when using Rigid Pipe Part 770 994 Maximum 35 5 ft 10 m 8 Minimum 8...

Page 32: ... Max 6 Min E 4 Min 5 Max 7 Min F 5 Min 6 Max 8 Min G 6 Min 7 Max 9 Min H 7 Min 8 Max 10 Min With these options max total pipe length is 30 feet with min of 10 feet total vertical and max 8 feet total horizontal Please note min 1 foot between 90o elbows is required One 90o elbow Two 45o elbows Lengths do not include elbow indicated Must use reducer 946 606 and rigid pipe adaptor 770 994 No Vent Res...

Page 33: ...ed Parts Part Description 946 529 Co linear DV Vertical Termination Cap 948 305 3 Flex 35 ft 946 563 Co Axial to Co Linear Adapter Kit whichcontainsthefollowing Co linear Flex Adapter Outer Pipe Inner Pipe Adapter 770 994 Rigid Pipe Adaptor 946 606 Vent Reducer Alternate Approved Caps 46dva VC Vertical Termination Cap 46dva VCH High Wind Cap 46dva GK 3 Co linear Adapter with flashing Flex Liner Ex...

Page 34: ...ista B36XT Gas Fireplace INSTALLATION VERTICAL TERMINATIONS CO LINEAR FLEX SYSTEM INTO MASONRY FIREPLACES FOR BOTH RESIDENTIAL MANUFACTURED HOMES The shaded area in the diagrams show the allowable vertical terminations ...

Page 35: ...fireplaceandfastenittotheframing using nails or screws through the top and side nailing strips Diagram 1 Note For best results and optimum performance with each approved venting system it is highly recommended to apply Mill Pac sealant supplied to every inner pipe connection Failuretodosomayresult in drafting or performance issues not covered under warranty Silicone red RTV is optional Diagram 2 H...

Page 36: ...asten the one with the tabs to the outside wall making sure that the tabs are on top and bottom Fasten the other thimble half to the inside wall The thimble halves slip inside each other and can be adjusted for 2 x 4 or 2 x 6 walls 5 Slip the assembled liner and termination assembly through the thimble making sure the termination cap faces up there are markings on the cap that show which wayis up ...

Page 37: ...stall the Firestop spacer in a flat ceiling or wall cut a 10 inch square hole Frame the hole as shown in Diagram 2 and install the firestop NOTE Forbestresultsandoptimumperform ance with each approved venting system it is highly recommended to apply Mill Pac sealant supplied toeveryinnerpipeconnec tion Failure to do so may result in drafting or performance issues not covered under warranty Silicon...

Page 38: ...ut do not over tighten Incorrect flame pattern will have small probably yellow flames not coming into proper contact with the rear burner or thermopile or thermocouple HIGH ELEVATION This unit is approved in Canada for altitude to 4500ft CAN CGA 2 17 M91 ForNaturalGas installations above 4500 ft follow current CAN CGA B149 1 S I T VALVE DESCRIPTION 1 Gas on off knob 2 Manual high low adjustment 3 ...

Page 39: ...rew the pilot orifice with the allen key then replace with the LPG pilot orifice provided in the kit 7 Remove the wire clip below the pilot cap 10 Re install pilot cap and pilot shield 11 Remove burner orifice with a 1 2 wrench Use another wrench to hold on to the elbow behind the orifice Discard orifice 12 Reinstall new burner orifice LPG stamped 51 and tighten Each Kit contains one LP Conversion...

Page 40: ... appropriate for the gas type 24 Replace yellow NG label with red LPG label Fig 1 Fig 2 Fig 4 Fig 3 19 Using the Allen wrench as shown in Fig 4 rotate the screw clockwise until snug do not overtighten 17 Insert a 5 32 or 4mm Allen wrench into the hexagonal key way of the screw Fig 2 rotate it counter clockwise until it is free and extract it 18 Check that the screw is clean and if necessary remove...

Page 41: ...XT Gas Fireplace 41 INSTALLATION DC Sparker Battery Replacement 1 Remove the battery cover from the DC Sparker remove the AA battery 2 Replace with a new AA battery and reinstall battery cover DC SPARKER BATTERY REPLACEMENT ...

Page 42: ...nd rear log tray so the panel is not damaged Note Ensure that an equal space gap is maintained on both the right and left side when installing the back panel 5 Remove the hex head screw on the upper left side of the firebox wall Position left brick panel in place and secure with the brick panel clip and screw 6 Slide top brick panel under left and back brick panel use care not to damage panel 7 Ri...

Page 43: ...r damage after installation will not receive consideration To protect the finish during installation and handling cotton gloves MUST be worn at all times while handling the panels even when removing protective coating Stainless panels will discolor a little during normal operation This is normal and should not be considered a defect Black Enamel panels will discolor a little during normal operatio...

Page 44: ... in place and secure with 1 screw see inset B Tighten the screw Location of hex head screw Diagram 6 Diagram 7 A A B B 22 4 BLACK ENAMEL PANEL INSTALLATION 1 Remove the heat deflector by removing the 2 screws securing the heat deflector to the top of the firebox see Diagram 2 Heat deflector Diagram 2 Diagram 6 Diagram 1 2 Install the back panel first use care when clearing the burner assembly and ...

Page 45: ...ight Log E Rear Log 902 156 Lava Rocks 902 179 Vermiculite 946 669 Platinum Embers supplied w packaged manual 1 Carefully remove the logs from the packaging and unwrap them The logs are fragile handle with care do not force into position 2 Spread vermiculite along the base of the firebox Vermiculite D E A C B 4 Place Log B on the front left side of the burner Position the notch on the bottom left ...

Page 46: ...ght side of the burner Position the notch on the bottom right side of the log into the right side of the grate Slide Log A back towards Log E until the flat surface on Log A rests up against the tabs on the burner and grate this maintains a necessary gap between Logs A E Note Use the notch on the bottom of Log A as a guide see below Tabs on burner grate Back of Log A A 7 The notch on the bottom of...

Page 47: ... rocks Avoid stacking platinum embers Platinum embers may be placed over burner ports 9 Position Log C with the flat side toward Log E Fit Log C onto left peg on Log E the notch on the bottom of Log C rests against the 3rd from the left grate post 10 Test fire to ensure proper light off make sure flame flows smoothly from one end of the burner to the other If there is any flame hesitation check th...

Page 48: ...TROL UsetheRegency RemoteControlKit approved for this unit Use of other systems may void your warranty The remote control kit comes with a hand held transmitter a receiver and a wall mounting plate 1 Choose a convenient location on the wall to install the receiver and the receptacle box protection from extreme heat is very important Run wires from the fireplace to that location Use Thermostat Wire...

Page 49: ...tions Note The bearings are lubricated for life Do not lubricate them Make sure you vacuum the fan area on a regular basis IMPORTANT These fans collect a lot of dust from within your home Ensure you maintain these fan motors on a regular basis by vacuuming out the fan blades and housing using a soft brush nozzle Push Fan down on mounting pins Electrical Receptacle Ground Lug Plug fan power cord i ...

Page 50: ...eration In case of a power failure the burner switch and the optional remote control thermostat will continue to operate However a 120V A C power supply is needed for the fan blower operation Proflame GTMF and light options Do not cut the ground terminal off under any circumstances NOTE Even if the fan GTMF system or light options are not purchased with the unit it is still a good idea to bring po...

Page 51: ... L O T Gas Pilot Thermopile Thermocouple Electrode Brown T Stat Black White S I T Valve Burner ON OFF To THTP To TH To TH White Gas In DC Spark Box Ground Ground Green Neutral Live Black Red Red Minimum Convection Air Temp Switch Ground ON OFF Rotary Speed Control 120V AC 60 Hz Fan Optional Fan WIRING DIAGRAM FOR GTMF REMOTE WIRING DIAGRAM FOR NG AND LP UNITS 2 ft wiring harness ...

Page 52: ...ndicates Included Feature Note 1 Proflame Flame Modulator for GTM GTMF Remote Controls are sold seperately Choice of NG or LP flame modulator to match unit fuel type See Regency Retail Price pages for complete details 1 1 1 Note Regency Proflame systems include a white and black wall cover switch ...

Page 53: ...the firebox base Discard cover plate keep the 2 screws 7 From inside the firebox feed the wires from the bottom of the light assembly through the opening exposed after the removal of the cover plate 8 When light assembly has been fully seated secure in place with 2 screws that were removed from the cover plate 9 From underneath the firebox slide back the protective sheath on the plug wiring to rev...

Page 54: ...base of the unit Ensure wiring does not come into contact with the fan blades or any sharp metal edges Wire Clip Gasket Ground Lug 16 Install a gasket over top of the bulb Installed diffuser shown below with 2 options a With amber glass plate for use with units without panels or with brick panels Left and right side tabs to be bent down 90 degrees as shown below Image A b Amber glass plate covered...

Page 55: ...install the gasket and light diffuser 5 Reverse steps 4 1 Ground Wire Receptacle BULB REPLACEMENT Lockwasher Fan ground wire Nut 8 Ground Lug mobile home approved Star washer Ground Green Neutral Live Black Red Red Minimum Convection Air Temp Switch Ground ON OFF Rotary Speed Control 120V AC 60 Hz Fan Optional Fan Light Switch Receptacle in Unit To Fan see above Optional Accent Light Ground L1 N B...

Page 56: ...ith tabs in firebox Hook slots on to tabs and lower door slowly See Diagram 1 2 Lower the flush door then hook the 2 adjustable tension latches close the latches to secure the flush door See Diagram 2 Diagram 1 Tabs in Firebox Diagram 2 Adjustable Tension Latch location Note To remove Flush Glass door reverse Steps 1 and 2 ...

Page 57: ...t the bottom bracket slots over the screws Tighten the 2 screws to secure in place Finishing Trim Edge of Unit B41XT B36XT W 43 3 8 40 1 2 H 37 5 8 35 3 4 OPTIONAL FINISHING TRIM INSTALLATION FLUSH LOUVERS AND FLUSH PANEL INSTALLATION To install the top and bottom louvers or flush panels 1 Locate the tabs on louvers flush panels 2 Line up the tabs on louvers flush panels with the brackets on the u...

Page 58: ...edoorframeonto4loosenedscrews and retighten 6 Install bottom mesh door a Locate tabs on bottom mesh door b Locate bracket on lower floor of unit c Hook the tab on the bottom mesh door over the bracket to install 7 Install top louver a Locate tabs on top louver 8 Rehang screen doors on frame See Diagram 7 Note The door frame is adjustable up by 3 4 to accommodate for finished flooring The door fram...

Page 59: ... glass should be cleaned after the unit has cooled down or the film will bake on and become very difficult to remove Use a non abrasive cleanerandDONOTATTEMPTTOCLEAN THE GLASS WHILE IT IS HOT TheFIRSTFIREinyourheaterispartofthepaint curing process To ensure the paint is properly cured it is recommendedyou burnyourfireplace for at least four 4 hours the first time When first operated the unit will ...

Page 60: ...n the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Forced or attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas cont...

Page 61: ...vice per son GLASS REPLACEMENT In the event that you break your glass by impact purchase your replacement from an authorized Regency dealer only Replacement glass Part 940 357 P is shipped already installed into the door frame Reinstall as per Glass Door Installation in the Glass Door Removal section MAINTENANCE INSTRUCTIONS 1 Always turn off the gas valve before cleaning Forrelighting refertoligh...

Page 62: ... from the valve see Diagram 5 Diagram 4 Diagram 3 Diagram 5 Diagram 6 Diagram 8 Diagram 7 INSTALLING VALVE 1 Place new valve tray into position 2 Reinstall the 8 hold down screws 3 Hook up the 2 TP and 2 TH wires to the ap propriate connections on the valve 4 Reinstall the rear log tray 5 Install burner grate assembly 6 Hook up the gas line and check for gas leaks with a soap and water solution or...

Page 63: ...tch 13 904 731 Capscrew 1 4 20 x 3 5 NC Gr5 14 940 357 P Ceramic Glass 15 556 012 Door Frame 16 Outerbox Assembly 17 Firebox Assembly Part Description 18 576 917 Fan Assembly 19 910 331 P Fan Motor 120 Volts 432 966 Fan Switch Assy 120 Volts 20 910 813 Power Cord 120 Volts 21 910 330 Fan Speed Control 22 904 586 Knob Speed Control 23 910 142 Thermodisc Fan Auto ON OFF 24 946 000 Round Duct Adaptor...

Page 64: ...64 Regency Bellavista B36XT Gas Fireplace PARTS LIST 23 FAN SWITCH ASSEMBLY FAN SWITCH ASSEMBLY 22 20 21 3 4 5 6 13 7 8 16 17 14 12 10 11 18 9 15 19 1 2 MAIN ASSEMBLY ...

Page 65: ...6XT Burner Assembly 4 576 057 B36XT Grate Assembly 5 904 644 Orifice 35 NG 904 645 Orifice 51 LP 6 910 568 Valve NG LP SIT High Low 820 7 Valve Tray B36XT Part Description 9 576 574 P Valve Assembly NG 576 576 P Valve Assembly LP 10 910 038 Pilot Assembly NG 910 039 Pilot Assembly LP 910 386 Thermocouple 910 341 Thermopile ...

Page 66: ...66 Regency Bellavista B36XT Gas Fireplace NOTES ...

Page 67: ...ent Transportation Prepaid if requested Porcelain Enamel Absolute perfection is either guaranteed nor commercially possible Any chips must be reported and inspected by an authorized dealer within three days of installation Reported damage after this time will be subject to rejection It is the general practice of FPI to charge for larger higher priced replacement parts and issue credit once the rep...

Page 68: ...______________________________________________ Phone ___________________________________________________________ Date Installed ______________________________________________________ Serial No __________________________________________________________ Register your Regency warranty online www regency fire com Reasons to register your product online today View and modify a list of all your register...