background image

EDH0214En1010 — 12/05

4

SMC-RC Remote Control for SMC100CC

Quick Start

1

EDH0214En1010 — 12/05

SMC-RC Quick Start

1.0

Overview

The SMC-RC is a remote control keypad for the SMC100CC motion con-
troller. It allows basic use of the SMC100CC controller without a computer
and features a 16 characters position display and four push buttons for con-
figuration, jogging, homing, and enabling/disabling motors. It comes with a
0.5 m long helix cable that plugs to the KEYPAD connector on the
SMC100CC.

CAUTION

The SMC-RC remote control keypad is only compatible with SMC100CC
with firmware version V2.00 or higher.

CAUTION

Before connecting or using the SMC-RC remote control keypad, it is

very important to read carefully the general safety precautions on

page 2 of the SMC100CC User’s Manual.

High jog deceleration:

Equal to the default acceleration (see value set in
the software utility or with the AC command).

Low jog velocity: 

Equal to the default velocity (see value set in the
software utility or with the VA command) divided
by 1000.

Low jog acceleration: 

Low jog velocity / 2s  (means final velocity is
reached after 2 seconds).

Low jog deceleration:

Equal to the default acceleration (see value set in
the software utility or with the AC command).

NOTE

Any jog motion always respects the software limits (see settings in the
software utility or with the SL and SR commands). When approaching a
software limit, the controller decelerates with the programmed accelera-
tion even if the jog buttons are pressed.

Pressing the Exec. button when the three most right letters are DIS, gets
the controller to the DISABLE state. In DISABLE state the motor is not ener-
gized and the control loop is open. But the encoder is still read and the cur-
rent position gets updated. The DISABLE state can be used for instance for
manual adjustments or to make sure that no energy goes to the motor. To
go from DISABLE state to the JOGGING state, press the Exec. button again.

The buttons of the keypad can get disabled by the JD command.

NOTE

The keypad does not allow stopping any motion started from a computer
(all buttons are disabled when the controller is in MOVING state). To
take computer control when the controller is in JOGGING state the con-
troller must first get to the READY state (change state from the software
utility or by using the JD command).

Newport Corporation, Irvine, California, has been certified compliant with ISO 9001 by the British Standards Institution

N e w p o r t   &   S p e c t r a - P hy s i c s   s a l e s   o f f i c e s

Bel

g

ium

Newport 

B

.V.

Phone: +32-(0)1 6402927

Fax: +32-(0)1 6402227

bel

g

ium@newport-

d

e.com

Fran

c

e

MICRO-CONTRO

LE

Phone: +33-(0)1-60-91-68-68

Fax: +33-(0)1-60-91-68-69

[email protected]

Germany / Austria

Newport 

G

m

b

H

Phone: +49 (0) 6151-708-0

Fax: +49 (0) 6151-708-954
verkauf@newport-

d

e.com

Italy

Newport/Micro-Controle It

a

li

a

Phone: +39-(0)2-929-0921

Fax: +39-(0)2-923-2448

[email protected]

Netherlands

Newport 

B

.V.

Phone: +31-(0)30 6592111

Fax: +31-(0)30 6592120

netherlan

ds

@newport-

d

e.com

United Kin

g

dom / Ireland

Newport 

L

td.

Phone: +44-(0)1635-521757

Fax: +44-(0)1635-521348

[email protected]

U

S

A

Newport Corpor

a

tion

Phone: +1-949-863-3144

Fax: +1-949-253-1680

s

ale

s

@newport.com

Germany / Austria / 

S

witzerland

NOTE

For a complete description
of all commands, please
refer to the SMC100CC
User’s Manual.

Single-Axis Motion Controller/Driver

for DC Motors

SMC100CC

U

SER

S

M

ANUAL

F

IRMW

ARE

V2.0

EDH0

206En1020 —

 12/05

2

SMC100CC

Single-Axis Motion Contr

oller/Driver for DC Motors

1.2

Warnin

gs and

 Cautions

The following are definition

s of the W

arnings, C

autio

ns a

nd N

otes that m

ay

be used

 in th

is m

anual to c

all attention to imp

ortant in

form

ation rega

rding

personal safe

ty, safety and p

reservation of the

 equip

ment, or imp

ortan

t

tips.

WAR

NIN

G

Situ

ation

 has th

e poten

tial to ca

use bod

ily harm

 or d

eath.

CAU

TIO

N

Situ

ation h

as the poten

tial to

 cau

se dam

age to

 prop

erty or

equip

ment.

NOTE

Additio

nal info

rma

tion 

the u

ser o

r op

erato

r sh

ould

 cons

ider

.

1.2.1

Gen

eral W

arn

ings a

nd Cau

tion

s

The

 follow

ing 

gen

eral sa

fety pr

ecau

tion

s mu

st b

e ob

serve

d dur

ing all

 phas

-

es of

 ope

ratio

n of th

is eq

uipm

ent.

Failur

e to co

mply

  with

 thes

e pre

cau

tions

 or w

ith spe

cific

  warn

ings e

lse-

wher

e in th

is m

anua

l vio

late

s safe

ty s

tandard

s of des

ign,

 manuf

actur

e, a

nd

intend

ed u

se of

 the

 equ

ipm

ent.

Heed

 all w

arnin

gs o

n th

e unit

 and

 in th

e op

erati

ng in

structions

.

To p

revent d

ama

ge to

 the equ

ipm

ent, rea

d th

e in

struc

tion

s in this m

anua

l.

Only plug

 the p

ower su

pply to

 a gr

oun

ded

 pow

er ou

tlet.

Assur

e th

at th

e pow

er su

pply is p

roper

ly g

rou

nded

 to ea

rth g

roun

d

throu

gh th

e grou

ndin

g lea

d of

 the A

C po

wer con

nect

or

Route

 pow

er co

rds a

nd c

ables

 wh

ere 

they

 are

 not lik

ely to

 be d

ama

ged

.

Disc

onne

ct o

r do no

t plug i

n the A

C pow

er c

ord

 in th

e fo

llow

ing c

ircum

-

stan

ces:

If th

e AC

 pow

er c

ord 

or a

ny othe

r atta

che

d ca

bles 

are fraye

d or da

m-

aged.

If the

 powe

r plu

g or

 rece

ptac

le is da

mag

ed.

If th

e un

it is expo

sed

  to ra

in or ex

cess

ive 

moistu

re, o

r liq

uids

  are

spille

d on

 it.

If the

 unit h

as bee

n drop

ped o

r the cas

e is d

amage

d.

If the u

ser su

spec

ts ser

vice o

r repa

ir is re

quire

d.

Keep air 

ven

ts free

 of dir

t an

d du

st.

Keep 

liquids a

way

 from

 unit.

Do n

ot exp

ose e

quip

men

t to

 exce

ssive

 mo

istur

e (>8

5% hu

midi

ty)

Do n

ot o

pera

te th

is equip

men

t in a

n ex

plosiv

e atm

osp

here.

Disco

nnect p

ower b

efore c

leaning th

e Co

ntro

ller/Driv

er u

nit. D

o no

t use

liquid

 or ae

rosol 

clean

ers.

Do no

t op

en th

e SM

C100

CC C

ontro

ller/D

rive

r. Th

ere a

re no 

user-se

rvice

-

able par

ts in

side.

Reviews: