Summary of Contents for ANI-8WP

Page 1: ...AUDIO VIDEO MANUFACTURER ANI 8WP 8 Button Wall Plate Control Keypad INSTRUCTION MANUAL A NeuVideo com Frisco Texas 75034 469 277 7606 ...

Page 2: ...ion 12 This unit should be installed in a cool dry place away from sources of excessive heat vibration dust moisture and cold Do not use the unit near stoves heat registers radiators or other heat producing devices 13 Do not block fan intake or exhaust ports Do not operate equipment on a surface or in an environment which may impede the normal flow of air around the unit such as a bed rug carpet o...

Page 3: ...following in mind as you unpack and install this equipment Always follow basic safety precautions to reduce the risk of fire electrical shock and injury to persons To prevent fire or shock hazard do not expose the unit to rain moisture or install this product near water Never spill liquid of any kind on or into this product Never push an object of any kind into this product through any openings or...

Page 4: ...ut Ports 8 Buttons Output Ports 1 Relay Terminal Block 24V 10A 100mOhms 1A 6VDC 1 IP Control RJ 45 Power Supply 5V 2 6A DC US EU standards CE FCC UL certified ESD Protection Human Body Model 8kV air gap discharge 4kV contact discharge Dimensions WxDxH 1 8 x 1 5 x 4 in 46x35 5x103 5mm Jack Excluded Weight 0 2 lb Unit only 1 1 lb Net Chassis Material Metal Color White Operating Temperature 32 F 104 ...

Page 5: ...at supports a relay function w CONTROL Connect from a PC Laptop with active internet service Telnet or WebGUI control via a RJ 45 terminated cable This slot supports the PoE PD 48V function which means when the connected server Hub supports PoE 48V it can be powered without the included DC supply e DC 5V Plug the 5V DC power adaptor included in the package and connect to an AC wall outlet for powe...

Page 6: ... descript of command N COMMAND NAME RELAY N N1 Relay control N PORT 1 N1 OPEN CLOSE TOGGLE LEDBLUE N N1 LED blue backlight control N LEN NO 1 8 N1 0 100 LEDRED N N1 LED red backlight control N LEN NO 1 8 N1 0 100 LEDBLUES N All blue LED backlight control N 0 100 LEDREDS N All red LED backlight control N 0 100 LEDSHOW N LED dimming mode control LEDSHOW N N ON OFF TOGGLE BACKLIGHT N All LED backligh...

Page 7: ...ile name ANI 8WP GUI_v2000 exe and save it in a directory where you can access it later Connect the Control System with a PC Laptop through the Ethernet port of an active network system and open the ANI 8WP GUI_v2000 exe Click on Find Devices on the Network and a list of the devices connected to the Control System will show up Note The default IP setting is 192 168 1 50 and set the Static IP or DH...

Page 8: ...and click on Run type cmd with then press ENTER Under Mac OS X go to Go Applications Utilities Terminal Once in the command line interface CLI type telnet then the IP address of the unit and 23 then hit ENTER This will bring us into the unit which we wish to control Type help to list the available commands Note Commands will not be executed unless followed by a carriage return Commands are case se...

Page 9: ... testing the Wall Plate s control system functionality Click on MACRO 1 6 to demonstrate the function of lighting the LEDs MACRO 1 Lights up the Red backlight LEDs with 100 brightness sequentially from 1 8 with every 500ms MACRO 2 Lights up the Blue backlight LEDs with 100 brightness sequentially from 1 8 with every 500ms MACRO 3 Switches off all the Red backlight LEDs with 0 brightness MARCO 4 Sw...

Page 10: ...Relay outputs of Wall Plate Control Box with delay time It is suggested the delay time is 100ms once the setting is confirmed double click on Save Change Commands set to control the device within the same Telnet system or internet area require to set its IP and Port number and it is strongly recommend to set the delay time 500ms in order to secure a successful command sending Once the setting is d...

Page 11: ...macro you can save some commands to an extension Macro and keep a command in Macro for MACRO RUN X to call an extension macro For instance if you want to run 20 commands you can save 15 to a Macro say Macro 1 and the other 5 commands to an Extension Macro say Extension Macro 11 Then you save MACRO RUN 11 as the last command of Macro 1 to call the commands saved in the Extension Macro After all the...

Page 12: ... over 128 characters and under 512 characters including spaces can be built up to 32 commands in addition to 96 commands of 128 characters and under Click on Save Change to save the commands inserted You can truncate commands in the command data field In other words you can put more than one data statement For Example LEDRED 1 100 x0d x0a RELAY 1 CLOSE x0d x0a DEVICE SETTINGS A NEUVIDEO ...

Page 13: ...these two commands in Command Settings 3 In Macro Settings save LEDRED 3 100 x0d x0a to Button 3 4 In Extension Macro save LEDRED 3 0 x0d x0a to Button 11 After saving the settings when you press Button 3 the first time the red LED will be ON and when you press it a second time the LED will be OFF When you turn on the toggle function for a button the first time you press the button the commands sa...

Page 14: ...ill retain the last date and time set in memory for up to 48hrs after power loss After 48hrs the system will reset the date and time automatically back to 2015 01 01 00 00 00 All other settings will remain Click on Edit from the Repeat column to set the macro command s to be activated repeatedly on a set time A NEUVIDEO ...

Page 15: ...Programming Click on Edit from the Once column to set the macro command s to be activated on a set time only Network Settings Click on Network Settings to reset the IP Netmask or Gateway address A NEUVIDEO ...

Page 16: ...m time and to enable disable the Daylight Saving Time DST function Simply click on the white column and a calendar will appear for your selection with current time settings Another simple few clicks to the enable disable the DST with its start and end Note The scheduling system will retain the last date and time set in memory for up to 48hrs after power loss After 48hrs the system will reset the d...

Page 17: ...15 CONNECTION DIAGRAM CONNECTION DIAGRAM A NEUVIDEO OR ...

Page 18: ...THIS PAGE IS INTENTIONALLY LEFT BLANK ...

Page 19: ...THIS PAGE IS INTENTIONALLY LEFT BLANK ...

Page 20: ...s offices within the State of Texas United States of America A NeuVideo makes no representation that materials pertaining to the Product are appropriate or available for use in other locations other than the shipping address you provided with respect thereto You are advised that the Product may be subject to U S export controls DISCLAIMERS AND LIMITATION OF LIABILITY A NeuVideo may change or modif...