Electronic temperature regulator for three-phase electrical water 

heaters, combined with two heat exchangers

NHC-H41

software version 2.1

User manual

NHC-H41

 is a temperature regulator with a modern and effective look, designed to control an 

electrical water heater, combined with a hot water installation with a solar collector and a boiler, a 
fireplace or any other similar installation. It has a graphic LCD display with the ability to show 
different types of information, which allows adding many new and useful options. Due to the two 
built-in differential temperature regulators in a joint controller, the advantages of the different heat 
sources are appropriately combined. For example, if the sun wasn't strong enough during the day, 
you can always set up the controller to turn the electrical heater on, so the water heater will be ready 
for you with enough hot water. If you have an installation with a fireplace or a boiler, the water 
heater   can   constantly  monitors   their   temperature   and   use   their   heat   to   warm   up   the   water,   if 
possible.

Specific advantages of the temperature regulator NHC-H41:

Uses energy from the electrical heater, if the water is not heated up enough by the solar 
collector

Automatically   uses   energy   from   a   boiler   or   a   fireplace   installation,   if   high   enough 

NHC-H41-2 Reference Manual ver 2.2

page  1 / 15

Summary of Contents for NHC-H41

Page 1: ...perature regulators in a joint controller the advantages of the different heat sources are appropriately combined For example if the sun wasn t strong enough during the day you can always set up the c...

Page 2: ...Two timers which allows you to set up the work time of the electrical heater This might be used for instance for automatic work only in the time interval with cheaper electricity rates or to set up a...

Page 3: ...f its work modes Automatic mode with electrical water heating Mode with electrical water heating in a restricted part of the day Combined mode 1 2 3 Solar mode Boiler mode Holiday mode for automatic p...

Page 4: ...stricted by a timer On this mode the water is heated up both by the electrical heater of the water heater and by the serpentine which is connected to the solar collector installation as the heater can...

Page 5: ...energy and the energy from the additional heat source is not enough and need to be used the electrical heater For instance if you need hot water in the night when there is no sun and the heating boil...

Page 6: ...ovide the required amounts of hot water Holiday mode If you are not using hot water for a long time for instance if you are on vacation business trip etc and during this season the sun is strong enoug...

Page 7: ...me of the set work parameters of the system All possible data is displayed successively by pressing the View Enter button It appears in the following order Set temperature Temperature of the water hea...

Page 8: ...he temperature sensor in the bottom section of the water heater It is on short circuit S1 Frost On turning on the power the water in the water heater has a negative temperature and it is possible to b...

Page 9: ...conds or until a button is pressed then the screen goes back to its initial state Important If the consumed daily or night electricity is displayed in the field Measured or set parameters pressing and...

Page 10: ...he registered problem can be found in the Measured or set parameters field Design III Settings The screen has a similar look for all the settings of the work parameters On the picture is the setting o...

Page 11: ...atic mode with electrical heating up the water and the display changes according to this mode By pressing again the Mode Set button the work mode of the water heater changes and the display changes to...

Page 12: ...off or which mode is currently activated the temperature regulator constantly monitors the temperature both of the water in the tank and of the solar collector and if it is necessary activates safety...

Page 13: ...off For a temperature difference between the collector and the water heater more than Pump On the pump will turn on and will work until the difference gets less than Pump Off 7 Setting the differenti...

Page 14: ...y network occurs no electricity For the battery not to run down if the water heater is off for a long time when there is no power supply for more than 18 hours the clock stops and on the next turning...

Page 15: ...ial settings use the following instructions the field which is going to be changed is blinking process to the next field of the same parameter by pressing button and the new field starts blinking incr...

Reviews: