background image

Wireless Recessed Door/Window Sensor 

RF-RDWS-345-NN                                      Installation Instructions

 

                                                                                                                              

 

         RF-RDWS-345-NN IM V1 08042020 

 

Description 

 

The Recessed Door/Window Sensor is a 

supervised, wireless sensor that detects the 

opening and closing of doors or windows. The 

sensor and magnet are recessed mounted 

into the frame. 

 

When activated, the sensor transmits an open 

(trip) or close (restore) signal to the panel. 

These are the signals the unit provides: 

supervisory and low battery (as needed). The 

sensor is powered by (1) replaceable 3-VDC, 

lithium battery. 

 

Mounting the Sensor 

 

  Verify mounting location before drilling 

any holes, the area must be able to 

accept an 11/16” hole to a depth of 2 

1/4” for the sensor and 5/8” for the 

magnet 

  The holes must be drilled directly 

across from each other to ensure the 

magnet and sensor operate properly 

  Using an 11/16” drill bit drill the hole 

for the magnet first, after drilling the 

magnet hole mark the location directly 

across for the sensor hole. 

  The magnet and sensor are slightly 

larger than the drilled hole to ensure a 

snug fit, a small amount of routing the 

hole may be required 

  Push both magnet and sensor into 

mounting holes 

 

 

 

Programming 

 

The following steps describe the general 

guidelines for programming the sensor into 

panel memory. Refer to the specific panel’s 

documentation for complete programming 

details.  

 

1. Set the panel to the program mode. 

  

2. Proceed to the SENSORS menu. 

3. Select the appropriate sensor group and 

sensor number assignments. 

4. When prompted by the panel to trip the 

sensor for learning:  

  Remove the cap from the sensor by 

using a screwdriver and twisting the 

cap 

  Pull the battery tab out to power the 

sensor 

  After the battery tab is pulled the 

sensor will transmit “tampers” for the 

first fives activations, the sensor 

should be enrolled during one of these 

first five trips. If the device is tripped 

too many times before enrollment the 

battery must be removed and re-

installed to activate the tamper trips 

again. 

  

5. Exit program mode.  

 

Testing the Sensor  

 

1. Set the panel to the sensor test mode.  

 

2. Monitor the system after tripping the 

sensor. Refer to the specific panel 

documentation for interpretation of the results 

to ensure desired signal strength is achieved.  

 

Note: 

If a low battery alarm occurs, replace 

the battery within 7 days.  

 

CAUTION

: Battery may explode if mistreated. 

Do not recharge, disassemble or dispose of in 

fire.  

 

Battery Replacement 

 

  Remove the sensor cap and 

carefully pull out the circuit board. 

  Push out the old battery towards the 

antennas and replace with a new 

battery.  

  Carefully slide board back into 

housing, note the slot for alignment. 

  Replace the cap and activate the 

device at least five times.  

Sp 

 

Mount in top or 

side of door 

Reviews: