background image

RSL12VDC

WIRING

DIAGRAM

01-37331B

CODE

MEANING

SOLUTION

31 *

Control board error

Remove power for 15 seconds. If code continues, 
replace control board. 

34

Absolute Position Issue

 

Check the operator cable connections, then reprogram 
the limits.  

35

Max-Run-Time Exceeded

Check for an obstruction, then reprogram the limits.

36

Product ID Error

Was the control board just replaced? If so, erase limits, 
enter limit setup mode and set limits. If not, disconnect 
all power, wait 15 seconds, then reconnect power 
before changing product ID harness.    

37

38 *

Hard Stop

Limit may be set too tightly against a hard stop 
(re-adjust limit). Operator may be at end of travel 
(re-adjust mounting). 

 

 

40

Battery overvoltage

Possible short of the battery charge harness. Check 
harness. Make sure you do NOT have a 12V battery 
on a 24V system.  

41

Battery overcurrent

42

No battery at boot up

Check battery connections. Replace batteries if 
depleted to less than 10V on 12V system or 20V on 
24V system.  

43

Failure or missing exit loop

(SHORT or OPEN - LiftMaster Plug-in Loop Detector 

only) 

Check loop wiring throughout connection. May 

be a short in the loop, or an open connection in the loop.   

 

44

Failure or missing shadow loop

45

Failure or missing interrupt loop

46

Low batteries in wireless edge

Replace batteries

53

Input voltage too low

Review power supply and wiring. If rebooting, 
wait for 15 seconds then reconnect power. 

60

No external entrapment protection 
devices installed 

Install at least one entrapment protection device (and 
ensure all entrapment zones are protected). 

 

61

CLOSE EYE/INTERRUPT (main board) Input held > 3 minutes. Check input on main board, 

check for alignment or obstruction.  

62

CLOSE EDGE (main board)

63

OPEN EYE/EDGE (main board)

64

CLOSE Edge

Input held > 3 minutes.  Check input on main board; 
check for alignment or obstruction. 

65

CLOSE EYE/EDGE

66

OPEN EYE/EDGE

67

Wireless edge input stuck on

Check input for wiring issue or obstruction.

68

Wireless edge lost signal

Check batteries, reposition edge receiver for clearer 
path to operator antenna. 

69 *

Wireless edge triggered

Remove obstruction, check inputs and wiring.

70 *

CLOSE EYE/INTERRUPT reversal, 
preventing close, or resetting TTC 

IF an obstruction occurred, no action required. 
If an obstruction did NOT occur, check 
alignment, inputs, and wiring.  

71 *

CLOSE EDGE triggered reversal, 
preventing close, or cancelling TTC

72 *

OPEN EYE/EDGE reversal or 
preventing opening

73 *

CLOSE EYE/INTERRUPT reversal, 
preventing close, or resetting TTC 
(expansion board)

74 *

CLOSE EYE/EDGE reversal and 
preventing close or cancelling TTC 
(expansion board)

75 *

OPEN EYE/EDGE reversal or 
preventing opening (expansion board)

80

Close input (EYE/EDGE) fault 
(Secondary operator)

Check the connections between the main board and 
the secondary operator. 

81

Open input (EYE/EDGE) fault 
(Secondary Operator)

82

Close input (EYE/EDGE) fault 
(expansion board)

Check the connections between the main board and 
the expansion board. 

83

Open input (EYE/EDGE) fault 
(expansion board)

91

Force reversal

Check for obstruction. If no obstruction, check that the 
operator arm is engaged and free to move. Check 
actuator's wiring. Refer to Limit and Force Adjustment 
section, and Obstruction Test sections in owner’s 
manual.  

93

Force reversal (RPM)

99

Normal Operation

No action required

* Codes marked with an asterisk are displayed in real time (as the condition occurs) and will not 
   be saved in memory. 

Unplug product ID harness then plug back in. 
Disconnect all power, wait 15 seconds, then reconnect 
power before replacing product ID harness.

Product ID Failure

47

Battery shorted

Check battery harness for short to chassis.

54

Wireless Second Operator 
Communication Error

Check the second operator for power. If OFF, restore 
power and try to run the system. If powered, deactivate 
the wireless feature and then re-learn the second 
operator.

50

Run-Distance Error

Gate unbalance detected. Make sure the gate is installed 
on a level surface and not on an excessive grade.

Reviews: